Briggs & Stratton 8000 Watt Portable Generator Maintenance Schedule, Generator Maintenance

Page 18

Maintenance

Maintenance Schedule

Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions noted below.

Maintenance Schedule - Fill in Dates as You Complete Regular Service

Maintenance Task

 

 

 

 

Service Intervals

 

Service Dates

 

Before

 

Every 25 Hours

 

Every 50 Hours

 

Every 100

 

Every 250

 

 

 

 

 

 

 

 

 

 

 

 

Each Use

 

or Yearly

 

or Yearly

 

Hours or Yearly

 

Hours or Yearly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean debris

X

 

 

 

 

 

 

 

 

 

 

 

Check oil level

X

 

 

 

 

 

 

 

 

 

 

 

Change engine oil

 

 

 

 

X1

 

 

 

 

 

 

 

Service air cleaner

 

 

X2

 

 

 

 

 

 

 

 

 

pre-filter

 

 

 

 

 

 

 

 

 

 

 

 

Service air cleaner

 

 

 

 

 

 

X2

 

 

 

 

 

paper filter

 

 

 

 

 

 

 

 

 

 

 

 

Service spark plug

 

 

 

 

 

 

X

 

 

 

 

 

Service spark arrester

 

 

 

 

 

 

X

 

 

 

 

 

Clean cooling system

 

 

 

 

 

 

X2

 

 

 

 

 

Check valve clearance

 

 

 

 

 

 

 

 

X

 

 

 

Prepare for storage

 

 

If unit is to

 

remain idle for longer than 30 days.

 

 

 

 

1Change oil after the first (5) operating hours and every 50 hours or every year, whichever occurs first, thereafter. Change oil sooner when operating under dirty or dusty conditions.

2Replace more often under dirty or dusty conditions.

General Recommendations

Regular maintenance will improve the performance and extend the life of the generator. See an authorized dealer for service.

The generator’s warranty does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual.

Some adjustments will need to be made periodically to properly maintain your generator.

All service and adjustments should be made at least once each season. Follow the requirements in the Maintenance Schedule chart above.

NOTE: Once a year you should clean or replace the spark plug and replace the air filter. A new spark plug and clean air filter assure proper fuel-air mixture and help your engine run better and last longer.

Emissions Control

Maintenance, replacement, or repair of the emissions control devices and systems may be performed by any non-road engine repair establishment or individual.

However, to obtain ”no charge” emissions control service, the work must be performed by a factory authorized dealer. See the Emissions Warranty.

Generator Maintenance

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture, or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves, or any other foreign material.

NOTE: DO NOT use water or other liquids to clean generator. Liquids can enter engine fuel system, causing poor performance and/or failure to occur. In addition, if liquid enters generator through cooling air slots, some of the liquid will be retained in voids and cracks of the rotor and stator winding insulation. Liquid and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.

Cleaning

Daily or before use, look around and underneath the generator for signs of oil or fuel leaks. Clean accumulated debris from inside and outside the generator. Keep the linkage, spring and other engine controls clean. Inspect cooling air slots and openings on generator. These openings must be kept clean and unobstructed.

Engine parts should be kept clean to reduce the risk of overheating and ignition of accumulated debris:

• Use a damp cloth to wipe exterior surfaces clean.

18

BRIGGSandSTRATTON.COM

Image 18
Contents Operator’s Manual Engine Where to Find UsGenerator Date PurchasedTable of Contents Safety alert symbol is used with a signal word Operator SafetySafety Rules Hazard Symbols and MeaningsEngine exhaust from this product contains Broken bones, fractures, bruises, or sprains could resultWhen Testing for Engine Spark Contact with muffler area can result in serious burnsUnintentional sparking can result in fire or electric shock Install the wheel kit as follows AssemblyInstall Wheel Kit Unpack GeneratorReplace oil fill cap and fully tighten Add Engine OilAdd Fuel Fuel must meet these requirementsTo install Attach Negative Battery CableConnecting to a Building’s Electrical System System GroundGenerator Location Clearances and Air MovementVolt AC, 20 Amp, Duplex Receptacles May be Features and ControlsUsed to supply electrical power for the operation Items Not Shown120/240 Volt AC, 30 Amp, Locking Receptacle Cord Sets and ReceptaclesNema L14-30 Volt AC, 20 Amp, Duplex ReceptaclesBattery Float Charger Operation Starting the EngineStopping the Engine Connecting Electrical LoadsOil Pressure Shutdown Cold Weather OperationCreating a Temporary Shelter An emergency, use the original shipping cartonCreating a Permanent Shelter Don’t Overload Generator Wattage Reference GuideMaintenance Maintenance ScheduleGenerator Maintenance Battery Maintenance Engine MaintenanceOil Wipe clean inside of base E and cover thoroughly Service Air CleanerTo service the air cleaner, follow these steps Service Spark PlugCarburetor Adjustment Install spark plug and tighten firmlyService Spark Arrester Air Cooling SystemStorage Troubleshooting Emissions Control System Warranty Owner’s Warranty ResponsibilitiesWarranties Maintenance Emission InformationClaims and Coverage Exclusions Limited Warranty Page Product Specifications Common Service Parts800 Manual del Operario Motor Dónde encontrarnosGenerador Fecha de compraMontaje Resolución de problemas GarantíasSeguridad de operario Controles y característicasReglas de seguridad Seguridad de operarioDescripción del equipo Símbolos de peligro y sus significadosCuando Opere EL Equipo Cuando Anada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Transporte O Repare EL EquipoCuando Ajuste O Haga Reparaciones a SU Máquina Generador Cuando Pruebe LA Bujía DEL MotorMontaje Desembalaje del generadorInstale el juego de ruedas El combustible debe reunir los siguientes requisitos Agregar aceite al motorAgregue combustible Gran altitudConexión al sistema eléctrico de un edificio Conecte el cable negativo de la bateríaTierra del sistema Para instalarUbicación del generador Espacio libre alrededor del generadorControles y características Amperios, monofásica de 60 HzTomas eléctricas dobles de 120 V CA y 20 a Juegos de cordones y enchufes conectoresDispositivo de seguridad de 120/240 V, 30 a Amps o mayoresCargador de flotación de la batería Operando Encienda el motorParada del motor Conexión de cargas eléctricasParada por falta de presión de aceite Operación durante un clima fríoCreación de una estructura de protección provisional Creación de una estructura de protección permanenteEjemplo No sobrecargar el generadorCapacidad Control de la energíaMantenimiento Plan de mantenimientoMantenimiento del generador Aceite Recomendaciones sobre el aceite Mantenimiento de la bateríaMantenimiento del motor Comprobación del Nivel de AceiteServicio del depurador de aire Cambio de aceite del motorAsegúrese de que la unidad esté en una superficie plana Servicio del bujíaSistema de refrigeración de aire Limpie la Pantalla ApagachispasLimpie e inspeccione el apagachispas de la siguiente manera Comprobación de holgura de la válvulaAlmacenamiento Resolución de problemas Problemo Causa AccionGarantías Garantía del sistema de control de emisionesResponsabilidades de la garantía del propietario Información sobre emisiones Garantía Limitada Page Especificaciones del producto Servicio común despide

8000 Watt Portable Generator specifications

The Briggs & Stratton 8000 Watt Portable Generator is a powerful and versatile solution for those in need of reliable electricity during outages, outdoor events, or job sites. As part of the renowned Briggs & Stratton lineup, this generator is designed to deliver robust performance, ensuring you have the power needed for essential appliances and tools.

One of the standout features of the Briggs & Stratton 8000 Watt Portable Generator is its impressive power output. With a starting wattage of 8000 watts and a running wattage of 6500 watts, this generator provides ample energy to support multiple devices simultaneously. Whether you need to power a refrigerator, air conditioner, or a range of power tools, the generator ensures that all your demands are met efficiently.

The generator is equipped with a 420cc engine, known for its durability and fuel efficiency. This engine is engineered to provide a reliable starting performance, even in cold weather conditions. With a large fuel tank capacity, the generator can operate for extended periods, allowing users to focus on their tasks without worrying about constant refueling.

Portability is another key characteristic of this generator. It features a compact design and is fitted with sturdy wheels and a foldable handle, making it easy to transport and maneuver. Whether you’re using it in your backyard or taking it to a remote job site, you can do so with ease.

Safety is paramount, and the Briggs & Stratton 8000 Watt Portable Generator includes advanced safety features such as an Integrated Low Oil Shutdown system that protects the engine from damage, ensuring longevity and performance reliability. Additionally, the generator's multiple outlet options, including standard 120V and 240V outlets, provide versatility for various power needs.

Another impressive aspect is the noise-reduction technology incorporated into its design. This allows the generator to operate quietly, minimizing disturbance, which is especially beneficial in residential areas or during nighttime use. With a solid warranty and support from a trusted brand, the Briggs & Stratton 8000 Watt Portable Generator represents an excellent investment for anyone seeking dependable portable power.

In summary, the Briggs & Stratton 8000 Watt Portable Generator combines high power output, robust engine performance, portability, and safety features, making it an ideal choice for users who require reliable and efficient electrical energy in various situations. Whether for home backup during outages or for professional use, this generator ensures that you are always powered up and ready to go.