Baldor manual Appendix a DG Series, DG3E and DG6E Operator Panel Configuration

Page 23

Appendix A

DG Series

Information in this Appendix applies to the following Baldor Generators:

DG3E and DG6E.

Caution: The brass connecting tab on some 120VAC duplex receptacles have been removed. Each receptacle is powered by a separate generator winding. When replacing a receptacle, inspect the brass tab that normally links both receptacles. If it is removed, be sure to remove the brass tab from the replacement receptacle before it is installed. Failure to remove the tab will cause a direct short to the generator windings and cause possible generator damage.

Operator Panel Configuration

Figure A-1 DG3E Operator Panel

 

 

AC VOLTS

ELAPSED

 

 

 

TIME

120V

120V

120/240V

 

 

 

OIL

AC BREAKERS

120 Volts NEMA 5−15R GFCI Receptacle.

This ground fault circuit interrupter duplex receptacle is rated at 125VAC, 15 Amps. 120 Volts NEMA L5−30R Receptacle.

Twist−lock style receptacle rated for 125VAC, 30 Amps. 120/240 Volts NEMA L14−30R Receptacle.

Twist−lock style receptacle rated for 125/250VAC, 30 Amps. AC Voltmeter.

This voltmeter displays the voltage level being produced by the generator set. Elapsed Time.

Displays the total run time hours of the generator set.

OIL Low Oil pressure indicator. Illuminates when oil pressure is low.

AC Circuit Breakers. Provide overload protection for the generator set.

Figure A-2 DG6E Operator Panel

ELAPSED

TIME

AC

VOLTMETER

AC CIRCUIT BREAKERS

120 VOLTS

120 VOLTS

120/240 VOLTS

Elapsed Time.

Displays the total run time hours of the generator set.

AC Voltmeter.

This voltmeter displays the voltage level being produced by the generator set.

AC Circuit Breakers.

Provide overload protection for the generator set.

120 Volts NEMA 5−15R GFCI Receptacle.

This ground fault circuit interrupter duplex receptacle is rated at 125VAC, 15 Amps.

120 Volts NEMA L5−30R Receptacle.

Twist−lock style receptacle rated for 125VAC, 30 Amps.

120/240 Volts NEMA L14−30R Receptacle.

Twist−lock style receptacle rated for 125/250VAC, 30 Amps.

120 VOLTS

MN2414

Premier K Series A-1

Image 23
Contents Diesel POW’R Products Generator California Proposition 65 Warning Table of Contents Ii Table of Contents MN2414 Read This Manual Thoroughly Section Product Safety InformationOperation Precaution Statements Used In This ManualProperty Operation Warning Statements Burn Installation Maintenance Product Safety Information MN2414 Labor Parts Limited WarrantySection General Information General Information MN2414 DG Series Generators Storage Section Receiving & InstallationPhysical Location Frame Ground Connection Receptacle ConnectionsEngine Oil Use of Electric Motor Loads Battery ConnectionsSummer Winter OIL Recommended Amps Cold Recommended Engine Oil and Battery Type Series DGAC Voltmeter Section OperationOperator Control Panel Elapsed TimeStopping Procedure Start−Up Procedure Electric StartEngine Section Troubleshooting and MaintenanceGeneral Service Problems and SolutionsTroubleshooting Guide Appendix a DG Series DG3E and DG6E Operator Panel ConfigurationTable A-1 Generator Set Parts List Replacement PartsTable A-1Generator Set Parts List Figure A-5 DG3E Wiring Diagram Figure A-6 DG3E Wiring Diagram with Low Oil & Remote Start Figure A-7 DG6E Wiring Diagram Baldor District Offices California Proposition 65 Warning