Agilent Technologies E8257D/67D manual Dhcp Configuration, Set LAN Config Manual Dhcp to Dhcp

Page 15

Getting Started

Configuring for Remote Control

6.Press IP Address and enter a desired address.

Use the left and right arrow keys to move the cursor. Use the up and down arrow keys, front panel knob, or numeric keypad to enter an IP address. To erase the current IP address, press the Clear Text softkey.

NOTE

To remotely access the signal generator from a different LAN subnet, you must also enter

 

the subnet mask and default gateway. See your system administrator to obtain the

 

appropriate values.

 

 

7.Press the Proceed With Reconfiguration softkey and then the Confirm Change (Instrument will Reboot) softkey.

This action assigns a hostname and IP address (as well as a gateway and subnet mask, if these have been configured) to the signal generator. The hostname, IP address, gateway and subnet mask are not affected by an instrument preset or by a power cycle.

DHCP Configuration

1.Press Utility > GPIB/RS-232 LAN > LAN Setup.

NOTE

If the DHCP server uses dynamic DNS to link the hostname with the assigned IP address,

 

the hostname may be used in place of the IP address. Otherwise, the hostname is not usable

 

and you may skip steps 2 through 4.

 

 

2.Press Hostname.

NOTE

Hostname field will only be available when the DHCP is off (Manual mode).

 

 

3.Use the labeled text softkeys and/or numeric keypad to enter the desired hostname. To erase the current hostname, press Editing Keys > Clear Text.

4.Press Enter.

5.Set LAN Config Manual DHCP to DHCP.

6.Press the Proceed With Reconfiguration softkey and then the Confirm Change (Instrument will Reboot) softkey.

This action configures the signal generator as a DHCP client. In DHCP mode, the signal generator will request a new IP address from the DHCP server upon rebooting. You can return to the LAN Setup menu after rebooting to determine the assigned IP address.

Chapter 2

11

Image 15
Contents Installation Guide Questions or Comments about our Documentation? Contents Regulatory Information Instrument Markings Safety InformationSafety Information General Safety ConsiderationsGetting Started Checking the Shipment Chapter Meeting Electrical and Environmental RequirementsEnvironment VentilationConnecting the AC Power Cord Line SettingsAC Power Cord Localization Screen Saver Configuring the DisplayContrast and Brightness Inverse VideoUpdating the Display During Remote Operation Configuring for Remote Control Gpib Interface ConfigurationLAN Interface Configuration Set LAN Config Manual Dhcp to Dhcp Dhcp ConfigurationRS-232 Interface Configuration Front Handle and Rack Mount Flange Kits Ordering AccessoriesFront Handles and Rack Mount Flanges E8257D/67D PSG DocumentationOrdering Accessories Cleaning Suggestions Proper Usage and CleaningContacting Agilent Sales and Service Offices Returning a Signal Generator to Agilent Technologies Returning a Signal Generator to Agilent Technologies Operation Verification Performing a Self-Test Self-Test Failure Maximum Leveled Power Check Failure Checking the Maximum Leveled PowerAmplitude Limits Checking the Output Power 540 Recommended Equipment for the E8267DRecommended Agilent Option 532 544 Checking the Output Power E8257D Option Amplitude Limits OptionAmplitude Limits Option DBm 1E1 ±0.9 1E1 & 1EA ±1.0 50 GHz None ±1.2 Option 532 E8267D OptionProblems with Output Power Regulatory Information Compliance with German Noise Requirements Statement of ComplianceAssistance CertificationCompliance with Canadian EMC Requirements Compliance with Canadian EMC Requirements Index IndexIndex

E8257D/67D specifications

Agilent Technologies has established itself as a leader in the realm of electronic testing and measurement, and the E8257D/67D signal generators are prime examples of its commitment to innovation and quality. These advanced signal generators are engineered to meet the rigorous demands of both research and development as well as manufacturing applications.

The E8257D/67D offers a frequency range of up to 67 GHz, making it suitable for a wide array of modern applications, including radar, satellite communications, and advanced wireless technologies. This wide frequency coverage is complemented by outstanding spectral purity and phase noise performance, which are crucial for applications that require high signal fidelity.

One of the standout features of the E8257D/67D is its ability to generate a variety of waveforms. In addition to traditional continuous wave signals, it supports frequency sweeping and pulse modulation, allowing users to design complex test scenarios that simulate real-world conditions. The instrument's high-resolution frequency and amplitude settings provide precision control, essential for characterizing high-performance components.

The E8257D/67D employs advanced digital signal processing technology that enhances both its accuracy and stability. This digital architecture allows for superior linearity and minimized distortion, which are vital parameters in many testing scenarios. Furthermore, the generator’s fast-switching capabilities enable rapid changes in frequency and amplitude, facilitating dynamic testing environments.

In terms of connectivity, the E8257D/67D supports various interfaces, including LAN, USB, and GPIB, allowing for seamless integration into automated test systems. This flexibility not only maximizes productivity but also simplifies system integration and data acquisition.

The user-friendly GUI (Graphical User Interface) of the E8257D/67D enhances the user experience, making it easier to navigate and configure settings. With its comprehensive set of built-in functions and measurement options, users can efficiently perform complex tasks without extensive training.

Overall, the Agilent Technologies E8257D/67D signal generators excel in providing high-performance signal generation capabilities. With its impressive specifications, versatility, and ease of use, it is an ideal choice for engineers and technicians seeking to ensure the highest standards in electronic design and testing. Whether in R&D labs or production lines, the E8257D/67D stands out as a reliable tool for advanced signal generation.