Agilent Technologies E8257D/67D manual 540, Recommended Equipment for the E8267D

Page 30

Operation Verification

Checking the Output Power

Table 3-2

 

 

 

 

 

Recommended Equipment for the E8257D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E8257D

 

E8257D

 

E8257D

 

E8257D

 

 

 

Recommended Agilent

Option

 

Option

 

Option

 

Option

Test Equipment

 

 

 

Test Equipment

520

 

540

 

 

 

550

 

567

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adapter,

 

Agilent 1250-1749 APC 3.5 (f) to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.5 (f) to (f)

 

(f) adapter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adapter,

 

Agilent 1250-1744

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.5 (f) to

 

APC 3.5 (f) to Type-N (m) adapter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type-N (m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adapter,

 

Agilent V281A Coax 1.85 mm (f) to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.85 mm (f) to

V-Band

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V-Band

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 3-3

 

 

 

 

Recommended Equipment for the E8267D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E8267D

 

E8267D

 

E8667D

 

 

 

 

 

Recommended Agilent

 

 

Option

 

Option

 

Option

 

Test Equipment

 

 

 

 

 

 

 

 

 

Test Equipment

 

 

 

520

 

 

532

 

 

544

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Meter

 

Agilent E4418B E-Series power meter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or Agilent E4419A/B E-Series power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

meter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Sensor,

 

Agilent E9304A E-Series power sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input: Type-N

 

or Agilent 8482A power sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Sensor,

 

Agilent E4413A E-Series power sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input: APC 3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Sensor,

 

Agilent 8487A Option H84 power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input: 2.4 mm

 

sensor Option H84 adds a Standards Lab

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(m)

 

 

Calibration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adapter,

 

Agilent 11900B 2.4 mm (f) to (f) adapter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.4 mm (f) to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(f)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26

Chapter 3

Image 30
Contents Installation Guide Questions or Comments about our Documentation? Contents Regulatory Information Safety Information Instrument MarkingsGeneral Safety Considerations Safety InformationGetting Started Checking the Shipment Ventilation Meeting Electrical and Environmental RequirementsEnvironment ChapterLine Settings Connecting the AC Power CordAC Power Cord Localization Inverse Video Configuring the DisplayContrast and Brightness Screen SaverUpdating the Display During Remote Operation Configuring for Remote Control Gpib Interface ConfigurationLAN Interface Configuration Dhcp Configuration Set LAN Config Manual Dhcp to DhcpRS-232 Interface Configuration E8257D/67D PSG Documentation Ordering AccessoriesFront Handles and Rack Mount Flanges Front Handle and Rack Mount Flange KitsOrdering Accessories Proper Usage and Cleaning Cleaning SuggestionsContacting Agilent Sales and Service Offices Returning a Signal Generator to Agilent Technologies Returning a Signal Generator to Agilent Technologies Operation Verification Performing a Self-Test Self-Test Failure Checking the Maximum Leveled Power Maximum Leveled Power Check FailureAmplitude Limits Checking the Output Power 540 Recommended Equipment for the E8267DRecommended Agilent Option 532 544 Checking the Output Power E8257D Option Amplitude Limits OptionAmplitude Limits Option DBm 1E1 ±0.9 1E1 & 1EA ±1.0 50 GHz None ±1.2 E8267D Option Option 532Problems with Output Power Regulatory Information Certification Statement of ComplianceAssistance Compliance with German Noise RequirementsCompliance with Canadian EMC Requirements Compliance with Canadian EMC Requirements Index IndexIndex

E8257D/67D specifications

Agilent Technologies has established itself as a leader in the realm of electronic testing and measurement, and the E8257D/67D signal generators are prime examples of its commitment to innovation and quality. These advanced signal generators are engineered to meet the rigorous demands of both research and development as well as manufacturing applications.

The E8257D/67D offers a frequency range of up to 67 GHz, making it suitable for a wide array of modern applications, including radar, satellite communications, and advanced wireless technologies. This wide frequency coverage is complemented by outstanding spectral purity and phase noise performance, which are crucial for applications that require high signal fidelity.

One of the standout features of the E8257D/67D is its ability to generate a variety of waveforms. In addition to traditional continuous wave signals, it supports frequency sweeping and pulse modulation, allowing users to design complex test scenarios that simulate real-world conditions. The instrument's high-resolution frequency and amplitude settings provide precision control, essential for characterizing high-performance components.

The E8257D/67D employs advanced digital signal processing technology that enhances both its accuracy and stability. This digital architecture allows for superior linearity and minimized distortion, which are vital parameters in many testing scenarios. Furthermore, the generator’s fast-switching capabilities enable rapid changes in frequency and amplitude, facilitating dynamic testing environments.

In terms of connectivity, the E8257D/67D supports various interfaces, including LAN, USB, and GPIB, allowing for seamless integration into automated test systems. This flexibility not only maximizes productivity but also simplifies system integration and data acquisition.

The user-friendly GUI (Graphical User Interface) of the E8257D/67D enhances the user experience, making it easier to navigate and configure settings. With its comprehensive set of built-in functions and measurement options, users can efficiently perform complex tasks without extensive training.

Overall, the Agilent Technologies E8257D/67D signal generators excel in providing high-performance signal generation capabilities. With its impressive specifications, versatility, and ease of use, it is an ideal choice for engineers and technicians seeking to ensure the highest standards in electronic design and testing. Whether in R&D labs or production lines, the E8257D/67D stands out as a reliable tool for advanced signal generation.