Philips SPX Cleaning the Lens, Safety, Cable Conductor colour codes Brown, Blue Neutral

Page 12

SPX Operation Manual

12

Cleaning the Lens

Remove the Lens Tube from the SPX.

Using a 3mm Allen Key, undo the retaining screws on the back and front of the tube.

Open the top cover on the lens tube.

As the lens is multicoated, clean with a soft cloth or lens tissue only. To remove baked-on dust use a window cleaner.

The above are the only maintenance tasks which can be safely carried out by non approved personnel. Refer below - Safety & Maintenance note.

Safety

Philips Selecon has manufactured this luminaire in accordance with recognised best practices to recommended international safety standards. It is your responsibility to maintain this luminaire in good & safe working condition.

Repairs should only be carried out by suitably qualified persons. Do not operate the luminaire with cracked lens, damaged cable, etc. Consult your Philips Selecon distributor for assistance. Only replace damaged parts with authorised Philips Selecon spares.

N.B. Luminaire Cable - Your Philips Selecon luminaire is fitted with special heat resistant flexible cable, replace with genuine Philips Selecon spare part cable kit only - refer to your Philips Selecon distributor. (Replacement cables are supplied complete with necessary terminal connectors.)

Cable Conductor colour codes:

 

Brown

- Phase, Live

Blue

- Neutral

As this luminaire is Double Insulated the Green/Yellow Earth wire may not be present and will have been cut back within the loom.

Version 1.1: 2010 © 2010 Philips Selecon All Rights Reserved

Image 12
Contents SPX Version 1.1 2010 2010 Philips Selecon All Rights Reserved Version 1.1 2010 2010 Philips Selecon All Rights Reserved Safety Warnings Operating your Luminaire for the First TimeLamp Replacement and Adjustment Centering the lampOptimising the Output Lamps Mounting your LuminaireTo Mount on a Theatre Standard Scaffold Pipe SPX Monocoque YokePan and Tilt Adjustment Focusing SPX Zoomspot ModelsFocusing SPX Fixed Beam Profiles Operating your LuminaireAccessory Mounting Positions Shutter LockRotatable Shutters Changing the Lens Tube Colour Filter LifeLens Tube Flat Peak Maintenance Electrical Test Procedure Safe PracticeRigging Check-list Cleaning the Reflector Equipment Insulation Test Minimum insulation Resistance MΩCleaning the Lens SafetyCable Conductor colour codes Brown Blue NeutralLimited Warranty Usage Entertainment, Theatre Term Three YearsAccessories and Order Codes Contacting Philips SeleconPhilips Selecon Philips Strand Lighting USA