Ariens 24 LE (920014 s/n 100000 & up) quick start Step Three Install Discharge Chute Crank

Page 10

Step Three: Install

Discharge Chute Crank

1.Remove gear cover from top of chute pedestal.

2.Slide Chute Crank through the nylon bushing in the support bracket under control panel.

NOTE: Be careful not to damage nylon bushing when attaching crank to the control panel.

3.Connect the chute crank to the pinion gear on discharge chute with spring clip pin.

4.Replace gear cover on top of chute pedestal.

5.Orient the chute and pedestal to its most vertical position and tighten pedestal hardware to 14.8-31.0 lbf-ft (20-42 N∙m).

Image 10
Contents Quick Start Guide Step One Assemble Handlebars Step One Assemble Handlebars Unfold Lower Handlebar Step One Assemble Handlebars Attach Upper Handlebar Assembly Step One Assemble Handlebars Attach Control Cables Step One Assemble Handlebars Unfold Upper Handlebar Step One Connect Headlight Wire Harness Step One Assemble Handlebar Step Two Install Discharge Chute Step Three Install Discharge Chute Crank Step Four Install Remote Deflector Cable Step Four Install Remote Deflector Cable Step Five Check Function of Dual Handle Interlock Step Six Check Tire Pressure Step Seven Adjust Skid Shoes Step Eight Check Auger Gearcase Oil Step Nine Check Engine Crankcase Oil Step Ten Fill Engine Fuel Tank Step Eleven Starting the Engine Starting Engine / Step a Throttle Starting Engine / Step B Fuel Valve Starting Engine / Step C Key Starting Engine / Step D Choke Starting Engine / Step E Prime Starting Engine / Step F Manual Start Starting Engine / Step F Electric Start Starting Engine / Step G Electric Start Starting Engine / Step H Warm up Step Twelve Stopping the Engine Additional Resources