■Electrical Adjustments
●Service Adjustment Menu Operation
To enter the service mode
To enter the “Service Mode”, press and hold theMENU and IMAGE button on the projector at the same time for more than 3 seconds. The service menu appears on the screen as follows.
To adjust service data
Select the adjustment group no. by pressing the MENU button, and select the adjustment item no. by pressing the pointer UP or DOWN button, and change the data value by pressing the VOLUME – or VOLUME + button. Refer to the “Service Adjustment Data Table” for further description of adjustment group no., item no. and data value.
To exit the service mode
To exit the service mode, press the POWER
Service Mode
Input Video
Group No. Data
0 0 32
Ver. 1 .00
ON
Group No. | Item No. Data value |
WARNING
TEMP.
MP | E |
LA | |
AC | |
PL |
|
RE |
|
VOLUME –
READY
LAMP
VOLUME +
INPUT | IMAGE | MENU | SELECT | ZOOM | FOCUS |
● Memory IC Replacement
IC1801 on the main board stores the data for the serv- | adjustments following to the “Electrical Adjustments”. |
ice adjustments, and should not be replaced except for | Please note that the lamp replace counter is reset. |
the case of defective device. |
|
If replaced, it should be performed the |
|
following to the “Electrical Adjustments”. | ● Caution of Main Board replacement (in the case |
The data of lamp replacement monitor timer is stored | IC1801 is not defective) |
in the IC1801. | When the main board is replaced, IC1801 should be |
Please note that the lamp replace counter is reset | replaced with the one on previous main board. After |
when the memory IC (IC1801) is replaced. | replacement, it should be required to perform the re- |
(Lamp replace counter can not be set to the previous | adjustments following to the “Electrical Adjustments”. |
value.) | In this case, the lamp replace counter can be kept the |
| value as before. |
● Caution to memory IC replacement |
|
When IC1801 is replaced with new one, the CPU |
|
writes down the default data of the service adjustments |
|
to the replaced IC, refer to the service adjustment |
|
table. As these data are not the same data as factory |
|
shipped data, it should be required to perform the re- |
|