Electrical Adjustments
PC Offset adjustment
1.Receive the
2.Set to COMPUTER mode.
3.Enter the service mode.
[R-OFFSET ADJUSTMENT]
4.Connect an oscilloscope to test point “TP25R1” (+) and chassis ground
5.Select group no. “3”, item no. “11” and change data value to adjust the waveform “a” (black portion ) to be maximum amplitude.
6.Connect an oscilloscope to test point “TP25G1” (+) and chassis ground
7.Select group no. “3”, item no. “12” and change data value to adjust the waveform “a” (black portion ) to be maximum amplitude.
8.Connect an oscilloscope to test point “TP25B1” (+) and chassis ground
9.Select group no. “3”, item no. “13” and change data value to adjust the waveform “a” (black portion ) to be maximum amplitude.
PC Gain adjustment
1.Receive the
2.Set to COMPUTER mode.
3.Enter the service mode.
[R-GAIN ADJUSTMENT]
4.Connect an oscilloscope to test point “TP25R1” (+) and chassis ground
5.Select group no. “2”, item no. “3” and change data value to adjust waveform “a” to be minimum ampli- tude.
6.Connect an oscilloscope to test point “TP25G1” (+) and chassis ground
7.Select group no. “2”, item no. “4” and change data value to adjust waveform “a” to be minimum ampli- tude.
8.Connect an oscilloscope to test point “TP25B1” (+) and chassis ground
9.Select group no. “2”, item no. “5” and change data value to adjust waveform “a” to be minimum ampli- tude.
White Level
(a)
(a)
Black Level