Current CPU Temperature/Current System Temp/Current FAN1, FAN2 Speed/Vcore/ Vdd/
This will show the CPU/FAN/System voltage chart and FAN Speed.
Detect CPUFAN in Post
During Enabled, system will warn the user if CPU Fan is not functioning.
3-11 Miscellaneous Control
This section is for setting CPU Frequency/Voltage Control.
CMOS Setup Utility – Copyright(C)
Miscellaneous Control
CPU Clock Ratio | 8X | Item Help | |
Auto Detect DIMM/PCI Clk | Enabled | ||
| |||
Spread Spectrum | Disabled | Menu Level > | |
** Current Host/PCI Clock is 100/33MHz ** |
| ||
Host/PCI Clock at Next Boot is | 100/33MHz |
| |
** Current DRAM Clock is 133MHz ** |
| ||
DRAM Clock at next Boot is | 133MHz |
| |
VCCQ Select | 1.5V(Default) |
| |
+2.5V Select | 2.5V(Default) |
| |
VDIMM Select | 2.6V(Default) |
| |
|
|
|
↑↓→← Move Enter:Select
F5:Previous Values | F6:Optimized Defaults F7:Standard Defaults |
Auto Detect DIMM/PCI Clk
This item allows you to enable/disable auto detect DIMM/PCI Clock.
Spread Spectrum
This item allows you to set the CPU Host/PCI clock and Spread Spectrum. The settings are: Enabled, Disabled.
Host Clock at next Boot is
This item allows you to select CPU frequency step by step increasing
The choice are: 100MHz∼132MHz, 133MHz∼165MHz, 166MHz∼255MHz.
DRAM Clock at next Boot is
This field displays the capability of the memory modules that you can use The choice is either 100MHz or 133MHz or 166MHz or 200MHz.
VCCQ Select
This item allows you to select 1.5V of the AGP 4X/8X VGA card. The choice are: 1.5V, 1.6V.
VDIMM Select
This item allows you to select 2.5V of the DDR Module. The choice are: 2.5V, 2.6V, 2.7V, 2.8V.