Hitachi cp-s318 user manual OPTION Menu, MULTIFUNCTIONAL SETTINGS continued

Page 36
OPTION Menu

CP-S317/327W/Vol2-E責了03.5.27 2:31 PM ページ 6

MULTIFUNCTIONAL SETTINGS (continued)

OPTION Menu

With the OPTION menu, the five items shown in the Table below can be performed.

Please perform each operation in accordance with the instructions in the Table.

MENU

MAIN

VOLUME

PICTURE-1

AUTO OFF

PICTURE-2

WHISPER

INPUT

LAMP TIME

SCREEN

FILTER TIME

OPTION

 

12

Manual background : SELECT

Example : OPTION Menu

(VOLUME)

OPTION Menu

Item

 

 

Description

VOLUME

Adjust Volume: High

Low

AUTO OFF

Adjust AUTO OFF Time:

Long (MAX. 99 min.) Manual backgroundManual background Short (Min. 1 min.) Manual backgroundManual background (DISABLE: 0 min.) The system automatically enters the standby mode if no signal is received within the set time. This function is inactive when DISABLE (0 min.) is selected.

WHISPER

Select WHISPER Mode:

NORMAL Manual backgroundManual background WHISPER

When WHISPER is selected the WHISPER mode is activated. In the WHISPER mode, acoustic noise and screen brightness are reduced.

Refer to LAMP TIME: When set, this function displays the total time the projector lamp has been used since new.

Reset LAMP TIME [Use this function only when the lamp has been replaced!]:

Depress the RESET button for at least 3 seconds while lamp time is being displayed. The reset menu will then appear. After you replace the lamp with a

LAMP TIME new lamp, select RESET on the menu with the Manual background button.

Do not reset the lamp time unless you have replaced the lamp. And, always reset the lamp time when replacing the lamp. The message functions will not operate properly if the lamp time is not reset correctly.

Before replacing the lamp, carefully read the descriptions headed "THE LAMP".

Refer to FILTER TIME: This function displays the total time the air-filter has been used since new.

Reset FILTER TIME [Use this function only when the filter is cleaned or replaced!]:

Depress the RESET button for at least 3 seconds while lamp time is being displayed. The reset menu will then appear. After you replace the filter, select

FILTER TIME RESET on the menu with the Manual background button.

DEFAULTManual backgroundManual background CANCEL

Do not reset the filter time unless you have cleaned or replaced the filter. And, always reset the filter time when cleaning or replacing the filter. The message functions will not operate properly if the filter time is not reset correctly.

Before cleaning or replacing the filter, carefully read the descriptions headed "THE AIR FILTER".

6

Image 36
Contents CP-S318W/CP-X328W MANUALE DISTRUZIONI Vol.1 Informazioni di baseBRUKERHÅNDBOK Vol.1 Grunnleggende ENGLISH DEUTSCH FRANÇAIS ITALIANO ESPAÑOL NEDERLANDS NORSK PORTGÊSCONTENTS SETTING UPCONNECTING USING THE REMOTEPROJECTOR FEATURES Ultra High BrightnessKeystone Distortion Correction Partial Magnification Function3 Connect the power cord Connect your devices to the projector8 ~ Insert the batteries into the remotePART NAMES THE PROJECTORTHE REMOTE CONTROL SETTING UP THE PROJECTOR Adjusting the Projectors Elevator FeetPress and hold in the elevator 1 buttons Raise or lower the projector to theAdjusting the Screen Size and Projection Distance If 43 aspect ratioIf 169 aspect ratio CONNECTING YOUR DEVICES Indicates the corresponding reference pagePorts and Cables NOTE About Plug-and-Play CapabilityCONNECTING YOUR DEVICES continued Connecting to a ComputerLaptop computer Desktop computerConnecting to a DVD Player Connecting to a VCRDVD player If using a componentConnecting to a Display Monitor Display monitorRGB OUT RGB IN USING THE REMOTE CONTROL Putting batteries into the remote control unitOperating the remote control 3 Closecover the batteryTURNING ON THE POWER PrecautionsMake sure that the power cord is firmly and Turn on the projectors powerSelecting an Input Signal Using the remote control If selecting RGB input Press the RGB buttonUsing the projectors control panel Press the INPUT button Use the zoom ring to adjust theTURNING OFF THE POWER panel or remote controlcontrol panel or remote control Check that the POWER indicator stopsADJUSTING THE VOLUME Press the VOLUME buttonbuttons to adjust the volumeADJUSTING THE POSITION 1 Press the POSITION buttonUse the the positionUSING THE AUTOMATIC ADJUSTMENT FEATURE Automatic Adjustment for RGB InputAutomatic Adjustment for Video Input Press the AUTO buttonCORRECTING KEYSTONE DISTORTIONS Press the KEYSTONE buttonbuttons to select the direction of distortion to correctUSING THE MAGNIFY FEATURE FREEZING THE SCREENPress the MAGNIFY ON button press the POSITION button again to confirm yourSIGNAL SEARCHING SELECTING THE ASPECT RATIOTEMPORARILY BLANKING THE SCREEN 1 Press the SEARCH buttonUSING THE MENU FUNCTIONS 2 Select a menu using theSelect an item using the buttons to adjust the levelYou can use the remote control as a simplified mouse or keyboard OPERATING THE PC SCREENPS/2, ADB, Serial Mouse Control USB Mouse/Keyboard ControlTHE LAMP THE LAMP continued Replacing the lampTurn off the projector, and unplug the power cord Apply a vacuum cleaner toto clean the air filter Turn on the projector, and use the menu to reset the filterTurn off the projector, and unplug the power cord. Prepare a Turn on the projector power, and using the menu, reset thefilter timer THE AIR FILTER continuedCaring for the cabinet and remote control transmitter OTHER CARECaring for the inside of the projector Caring for the lensCP-S317/327W/Vol2-E責了 03.5.27 230 PM ページ MULTIFUNCTIONAL SETTINGS MAIN MenuMAIN Menu PICTURE 1 Menu PICTURE 2 MenuPICTURE1 Menu PICTURE2 MenuMULTIFUNCTIONAL SETTINGS continued INPUT MenuINPUT Menu SCREEN Menu SCREEN MenuOPTION Menu OPTION MenuRelated Messages WHAT TO DO WHEN YOU THINK A MACHINE DEFECT HAS OCCURREDRegarding the Indicator Lamps Flashing of the green lampThe green lamp is lighted Flashing of the orange lampWHAT TO DO WHEN YOU THINK A MACHINE DEFECT HAS OCCURRED continued Phenomena That May Easily Be Mistaken for Machine DefectsSPECIFICATIONS Dimension DiagramSpecification WARRANTY AND AFTER-SERVICE SIGNAL CONNECTOR PIN ASSIGNMENT TECHNICALCP-S318/328W/TECHNICAl責了 03.5.27 239 PM ページ EXAMPLE OF COMPUTER SIGNAL ResolutionSignal mode fH kHzINITIAL SET SIGNALS The following signals are used for the initial settingsCONNECTION TO THE MOUSE CONTROL ADB MouseUSB Mouse PS/2 MouseCommunications setting 3 Command dataCommand data chart RS-232C COMMUNICATIONRequesting projector status Get command Changing the projector settings Set commandUsing the projector default settings Reset Command Increasing the projector setting value Increment commandCommand data chart Command data chart continued Default H.PhaseContrast KeystoneHCommand data chart continued REGULATORY NOTICES FCC Statement WarningFor the Customers in CANADA Pour les utilisateurs au CanadaQR57451