Hitachi CP-X1200 user manual Caring For The Air Filter

Page 54

Air Filter

WARNING • Please carefully read the “User’s Manual - Safety Guide.

Before caring, make sure the power switch is off and the power cable is not plugged in, then wait at least 45 minutes for the lamp to cool sufficiently.

Use only the air filter of the specified type NJ08081.

Do not use the projector with the air filter and filter cover removed. The use without the air filter could result in damage.

CAUTION • If the air filter becomes clogged by dust or the like, internal temperature rises and could cause malfunction. The power is automatically turned

off in order to prevent the projector from overheating internally.

Caring For The Air Filter

The air filter should be cleaned about every 100 hours. If the indicators or a message prompts you to clean the air filter, clean the air filter as soon as possible.

If the soiling will not come off the air filter, or it becomes damaged, then it needs to be replaced. Please replace the air filter as soon as possible.

memo When you replace the lamp, please replace also the air filter.

1

Turn off the projector, and unplug the power cord. Allow the lamp bulb to cool for at

least 45 minutes.

 

After making sure that the projector has cooled adequately, remove the filter cover

2

and air filter.

3

Apply a vacuum cleaner to the top of the filter cover and

the air filter to clean.

If the soiling will not come off the air filter, or it becomes damaged, it needs to be replaced.

If the air filter needs to be replaced, contact your dealer to prepare a new air filter. Tell the dealer your air filter type.

Hold the release buttons of the filter cover while pulling down it.

4

Insert the cleaned air filter or a new air filter, and replace

the filter cover.

Turn on the projector power, and reset the filter timer.

5 (1) While the projector running, press the MENU button to open the menu.

(2)Choose the “OPTION” on the menu using the / button, then press the button or ENTER button.

(3)Choose the “FILTER TIME” using the / button, then press and hold the RESET button for 3 seconds.

(4)Choose the “RESET” using the button.

Hold the release button of the air filter while pulling out it.

memo Incorrectly resetting of the filter timer (resetting

without replacement, or neglect of resetting after replacement) will result in incorrect message functions.

39

Image 54
Contents CP-X1200 / CP-X1250 About The Symbols Safety Precautions Safety Precautions Be careful in handling the light source lamp Be careful in moving the projector Do not give the remote control any physical impact Take care not to fatigue your eyes Lamp Regulatory Notices Contents Of Package ArrangementIf using a BNC input Connecting Your DevicesIf using a M1-D input to mouse control ComputerProjectorMonitorProjector If using a s-video signalIf using a component signal SpeakerProjectorConnecting The Power Supply Adjusting The Projectors ElevatorPreparing Remote Control People. The laser beam can cause vision problemsTrademark Acknowledgment Projector Features PreparationContents Projector Front/Right Part NamesProjector Audio in 1 port E Audio in 2 portRemote Control Remote ControlControl Buttons Setting Up ArrangementAdjusting The Projectors Elevator Using The Lens Shift Buttons100 Connecting Your Devices Examples of connection with a computer If using a Scart RGB input CR/PR Scart CB/PBAudio Scart Audio IN-L Video Connecting The Power Supply Remote Control About The Laser PointerPutting Batteries Operating The Remote Control Using The Remote ID FeatureUsing The Mouse/Keyboard Control Function Power ON/OFF Turning On The PowerTurning Off The Power Selecting An Input Signal OperatingAt a RGB signal not M1-D At a video signal Using The Automatic Adjustment FeatureAt a M1-D signal At a RGB signalPosition Use the cursor buttons Adjusting The Picture PositionCorrecting The Keystone Distortion Dialog and complete this operationAdjusting The Volume Muting The SoundTemporarily Blanking The Screen Using The Magunify Feature Freezing The ScreenPress the Magnify Button Displaying The Child Window Selecting An Audio InputMultifunctional Settings Using The Menu FunctionsEx. Turning off the built-in speaker Main Menu PICTURE-1 Menu PICTURE-1 Menu LOAD1 LOAD2 LOAD3 LOAD4SAVE1 SAVE2 SAVE3 SAVE4 PICTURE-2 Menu PositionSize Component Input MenuColor Space 3D-YCSInput Menu Power on AdjustPower OFF Auto MenuSearch Auto MenuRGB BNC Video ComponentStart UP Screen MenuBlank Menu PositionHow to register your picture as the MyScreen Screen MenuMessage Option Menu Option Menu Dhcp SetupNetwork Menu OFFNetwork Setting Up Click Return to top Click Reboot to complete this operationEx. Case of IP Address = Lamp Replacing The Lamp Dealer to replace the lampKnob Air Filter Caring For The Air FilterCaring For The Inside Of The Projector Caring For The Cabinet And Remote ControlOther Care Caring For The LensTroubleshooting Related MessagesRelated Messages Regarding The Indicator Lamps Regarding The Indicator Lamps Such as by a power outage blackout, etc Phenomena That May Easily Be Mistaken For Machine DefectsPhenomena That May Easily Be Mistaken For Machine Defects Sound is mutedWarranty And After-Service SpecificationsDimensions TechnicalExample Of Computer Signal Vesa TextVesa Initial Set Signals Connection To The Ports Dia. Stereo mini jack MVrms, 57k Ω terminatorVideo Mini Din 4 pin jackPlug Jack RS-232C portRTS D-Sub 9 pin RJ-45 10BASE-T jackConnecting The Cable Communications SettingRS-232CCommunication Requesting projector status Get command Command Data Chart Command Data Chart FrançaisBe EF EF F6 Be EF EC D9 Auto RGB Turn on Be EF Be EF BA D2 RGB Be EF Be EF RGB