Troubleshooting (continued)
Regarding The Indicator Lamps (continued)
STANDBY/ON | LAMP | TEMP | Description | |
indicator | indicator | indicator | ||
|
|
|
| Either there is no lamp and/or lamp cover, or |
|
|
| either of these has not been properly fixed. |
|
|
| Please turn the power off, and allow the unit to cool down at |
Lighting | Blinking | Turned | least 45 minutes. After the projector has sufficiently cooled |
in Red | in Red | off | down, please make confirmation of the attachment state of |
|
|
| the lamp and lamp cover, and then turn the power on again. |
|
|
| If the same indication is displayed after the treatment, |
|
|
| please contact your dealer or service company. |
|
|
| The cooling fan is not operating. |
|
|
| Please turn the power off, and allow the unit to cool down at |
|
|
| least 20 minutes. After the projector has sufficiently cooled |
Lighting | Turned | Blinking | down, please make confirmation that no foreign matter has |
in Red | off | in Red | become caught in the fan, etc., and then turn the power on |
|
|
| again. |
|
|
| If the same indication is displayed after the treatment, |
|
|
| please contact your dealer or service company. |
|
|
| There is a possibility that the interior portion has | |
|
|
| become heated. | |
|
|
| Please turn the power off, and allow the unit to cool down at | |
|
|
| least 20 minutes. After the projector has sufficiently cooled | |
Lighting | Turned | Lighting | down, please make confirmation of the following items, and | |
then turn the power on again. | ||||
in Red | off | in Red | ||
• Is there blockage of the air passage aperture? | ||||
|
|
| ||
|
|
| • Is the air filter dirty? | |
|
|
| • Does the peripheral temperature exceed 35°C? | |
|
|
| If the same indication is displayed after the treatment, | |
|
|
| please change the lamp by referring to the section “Lamp”. |
|
| There is a possibility that the interior portion has | |
Lighting | Alternative | become overcooled. | |
Please use the unit within the usage temperature | |||
in Green | Blinking in Red | ||
parameters (0°C to 35°C). After the treatment, resent the | |||
|
| ||
|
| power to ON. |
|
| It is time to clean the air filter, or there is no air |
Lighting | Simultaneous | filter. |
Please immediately turn the power OFF, and clean or | ||
in Green | Blinking in Red | change the air filter by referring to the section “Air Filter”. |
|
| After cleaning or changed the lamp, please be sure to reset |
|
| the filter timer. After the treatment, resent the power to ON. |
44