DLE EOT |
|
|
|
| EXECUTING COMMAND | |
|
|
|
|
| ||
[Name] |
| |||||
|
|
| ||||
[Format] | ASCII | DLE | EOT | n |
| |
| Hex | 10 | 04 | n |
| |
| Decimal | 16 | 4 | n |
|
[Range]
[Default]
[Description]
1 ≤ n ≤ 4, 6 None
Transmits the selected printer status specified by n in
n = 2: Transmit offline status
n = 3: Transmit error status
n = 4: Transmit paper roll sensor status
n = 6: Transmit validation status
•n = 1: Printer status
Bit | Off/On | Hex | Decimal | Function |
|
|
|
|
|
|
|
0 | Off | 00 | 0 | Not used. Fixed to Off. |
|
|
|
|
|
|
|
1 | On | 02 | 2 | Not used. Fixed to On. |
|
|
|
|
|
|
|
2 | Off | 00 | 0 | Drawer open/close signal is LOW (connector pin 3). |
|
|
|
|
|
|
|
| On | 04 | 4 | Drawer open/close signal is HIGH (connector pin 3). |
|
|
|
|
|
|
|
3 | Off | 00 | 0 | Online. |
|
|
|
|
|
|
|
| On | 08 | 8 | Offline. |
|
|
|
|
|
|
|
4 | On | 10 | 16 | Not used. Fixed to On. |
|
|
|
|
|
|
|
5 | Off | 00 | 0 | Reserved. Fixed to Off. |
|
|
|
|
|
|
|
6 | Off | 00 | 0 | No panel switch is pressed. |
|
|
|
|
|
|
|
| On | 40 | 64 | One of panel switch is pressed. |
|
|
|
|
|
|
|
7 | Off | 00 | 0 | Not used. Fixed to Off. |
|
|
|
|
|
|
|
Bit 6: | Even if panel switch is disabled by ESC c 5, bit6 becomes “On” during one of panel switch is pressed. |