Epson E02 manual Setting the IP Address Using the arp/ping Command

Page 37

UB-E02 Technical Reference Guide

3.1.2 Setting the IP Address Using the arp/ping Command

You can set the IP Address using the arp/ping command. This way of setting is available with the host, which is in the same segment as that of the UB-E02.

CAUTION:

When setting the IP address of the UB-E02, do not use the same IP addresses as that of other network devices or PCs.

Here is an example of setting the IP address to 192.168.100.201.

You will set the gateway address to the computer in which you will input the arp/ping command.

If a server or router acts as a gateway, type the gateway address.

If there is no gateway, type the IP address of your computer.

If you do not know the gateway address, ask your network administrator for it.

Note:

The IP address cannot be set without setting the gateway address.

1.Connect the printer with the UB-E02 installed to the network and turn on the printer.

2.Execute the commands as described in the following steps.

Note:

Be sure to execute the commands within 2 minutes. After 2 minutes, you must restart the commands from the beginning.

3.Make the connection between the IP address which you want to set and the MAC address of the UB-E02 by executing an arp command.

From the command line, type: arp-s [IP address] [MAC address]

Example using DOS: arp-s 192.168.100.201 00-00-48-83-00-00

Example using UNIX: arp-s 192.168.100.201 00:00:48:83:00:00

CAUTION:

When the UB-E02 is installed on the printer and the MAC address on the label on the UB-E02 cannot be seen for sure, turn off the printer and then remove the UB-E02 to confirm it.

Note:

The MAC address can be found on the status sheet or a label on the UB-E02. For printing the status sheet, refer to the Initializing UB-E02 and Status Sheet Printing section in Chapter 2.

Rev. A

Utilities 3-11

Image 37
Contents UB-E02 Technical Reference Guide Page Rev. a Revision Information About This Guide Contents of the GuideRelated Documents CE Marking EMC and Safety Standards AppliedFCC Compliance Statement For American Users For Canadian UsersGereäuschpegel Key to SymbolsProduct Servicing Safety PrecautionsLabel Introduction Environments for Setup UtilityOperating Environments Supported Operating SystemsSupported TM Printers Installation Overview How to Use this GuideProgramming AppendixContents Rev. a Contents Xii Contents Rev. a Supported Network Protocols Supported Operating SystemsOther Limitations Installation Precautions InstallationUnpacking SwitchPart Names FunctionsUB-E02 Installation 4Installation Rev. a Page 6Installation Rev. a UB-E02 Status Sheet Printing Initializing UB-E022 Q2. The self test does not operate correctly FAQ3 Q3. Starting up the printer takes a long time UB-E02 Technical Reference Guide 10Installation Rev. a Setting the IP Address using Epson TMNet WinConfig Setting the IP AddressSetting the TCP/IP protocol in Your Operating System Windows UB-E02 Technical Reference Guide Windows NT Windows Installation Environments Installing Epson TMNet WinConfigInstallation with Windows Setting with the Epson TMNet WinConfig UB-E02 Technical Reference Guide Page Setting the IP Address Using the arp/ping Command Example ping Epson TMNet WinConfig Functions Menu Bar Tool Menu Time-out settingSearch Options Settings Printer Print server TCP/IP Password Opening Screen Epson TMNet WebConfig FunctionsTCP/IP General Information Protocol Information and SettingsApipa 2.2 TCP/IP InformationSnmp Information 2.4 TCP/IP Setting Snmp Communication Setting Snmp IP Trap 1 Setting Snmp IP Trap 2 Setting Administrator Setting Password Setting Reset Advanced Programming Samples Buffer of the UB-E02 Method of Printing to the UB-E02For Windows Console Direct Printing by PORT91004Programming Samples For Linux Monitoring of the ASB status Commands Sent to a TM Printer When the Power is OnPriorities of Printing Time-out for ConnectionCommands Packets Printer Operation by the UDP Commands3 03-0010 Retrieving Status 2 03-0000 Retrieving Basic InformationReply data 4 03-0011 Forced Transmission 5 03-0012 ResetSet-up data 6 03-0013 Buffer Flash 7 03-0016 Clearing Connection Time-Out TimerFor Windows Console Programming Sample12Programming Samples Rev. a 13Programming Samples For Linux14Programming Samples Printer Connection FeaturesLine Display Connection OverviewHardware Specifications External appearance and connector locations Software SpecificationsBasic Communications Protocols Printing Communications ProtocolsHttp Status Inquiry and Setting ProtocolsSnmp MIB Enpc Automatic IP Address Assignment ProtocolsIP Address Acquisition by Dhcp IP Address Assignment by Apipa Manual SettingItem List Internal SettingsSetting with Exclusive utility Internal Parameter Setting MethodsSetting with Browser Setting the IP Address with arp + pingInitializing Upgrade MethodsVersion Upgrading Supported protocolStorage Conditions Environmental SpecificationsDefinitions 2Definitions Rev. a Page Epson