(5) 6000 - Fuser unit error
Call service
6000:nnnnnn
Turn power switch off, and remove power cable.
Detach connector CN4 on power supply board.
Measure resistance |
| |
between pins 1 and 2 |
| |
of the detached |
| |
connector. |
| |
Open (infinite)? | Yes | |
| ||
No | Replace thermistor. | |
See page | ||
| ||
Detach connector CN1 |
| |
on power supply board. |
| |
Measure resistance |
| |
between pins 1 and 3 |
| |
of the detached |
| |
connector. |
| |
No |
| |
Open (infinite)? | Yes | |
| ||
No | Replace thermal cutout | |
or heater lamp. | ||
| See page |
Printer indicators
Replace engine board
"6000" error | No |
| |
shown? |
|
Yes
Replace harness (S02772) between engine board
"6000" error | No |
| |
shown? |
|
Yes
Replace bias board or high voltage board or power supply board. See page
End.