Interlock switch
The interlock switch is located on the high voltage board and opened and closed in conjunction with the front cover or the top cover via the interlock lever. This switch connects and disconnects the +24 V DC power supply line. If the front cover or the top cover is open, the interlock switch is open, and the +24 V DC to the high voltage output circuit, bias board, engine board, and the power supply board is disconnected, deactivating the high voltage output, laser output, main motor output for safety. The cooling fan is an exception: Since the cooling fan is directly fed with +24 V DC from the power supply unit at the primary side (+24V1) of the interlock switch, the cooling fan is not deactivated even the cover is open.
Top cover
Projection
Interlock lever
Projection
Engine board,
Bias board,
etc.
Power supply unit |
|
| |
| High voltage | Interlock | |
| output circuit | ||
Triac, etc. | switch | ||
| |||
|
| ||
| +24V2 |
|
+24 V DC |
|
| +24V1 | |
output |
|
|
| High voltage board |
|
|
|
| |
|
|
|
| |
Cooling fan |
|
Front cover
Machine left side view