4413-XXX 
  | FRU | Action  | 
  | 
  | 
  | 
6  | Maintenance  | A problem with the maintenance station can cause  | 
  | Station  | carrier movement problems at the right margin. Go  | 
  | 
  | to the “Maintenance station removal” on | 
  | 
  | page   | 
  | 
  | 
  | 
7  | Access Door  | If the carrier does not move toward the cartridge  | 
  | Sensor  | load position when the access door is opened,  | 
  | 
  | verify that power is on. If the carrier still does not  | 
  | 
  | move, replace the system board. Go to the  | 
  | 
  | “System board removal” on page  | 
  | 
  | 
  | 
CIS assembly service check
The CIS lamp does not light when scanning is in process.
  | FRU | Action  | 
  | 
  | 
  | 
1  | CIS Assembly  | If light does not come on during the  | 
  | 
  | scanning process, check connector  | 
  | 
  | CN6 on the system board. If the  | 
  | 
  | connection is okay, replace the CIS  | 
  | 
  | assembly. Go to the “CIS (Contact  | 
  | 
  | Image Sensor) removal” on | 
  | 
  | page   | 
  | 
  | replace the system board. Go to the  | 
  | 
  | “System board removal” on | 
  | 
  | page   | 
  | 
  | 
  |