www.emersonct.com
Definition - DC StandardPak Order Code Configurator
Item | Description | |
Enclosure Style | P = Panel allows additional options to be added to the Quantum III module. | |
P = Panel | E = The enclosure option is a UL1 rated, ventilated Nema | |
E = Enclosure | 14 gauge steel enclosure. | |
|
| |
Drive Type | N for | |
N = | controlled braking action. | |
R = Regenerative | unless dynamic braking is used. | |
|
| |
Voltage Rating |
| |
8 = 208 VAC |
| |
2 = 240 VAC | 240 VAC for 240 VDC motor armature. | |
3 = 380 VAC |
| |
4 = 480 VAC | 480 VAC for 500 VDC motor armature. | |
|
| |
Drive Amp Rating - Armature | Motor hp ratings are based on typical motor current ratings. Actual motor currents and the type of applications should | |
| be reviewed before selecting drive size. | |
|
| |
Dynamic Braking (DB) | QuantumPak supplied with DC contactor (B), MentorPak supplied with AC contactor (A) as standard. Consult Factory | |
for drives 210A or above with DC contactor. | ||
A = AC Input Contactor | ||
A = AC Input Contactor | ||
B = DC Contactor with DB pole | ||
B = DC Contactor with DB pole | ||
| ||
|
| |
Input Power Disconnect | 1 – CB with through the door operator, | |
0 = None | Includes drive input semiconductor fuses. | |
1 = Circuit breaker (CB) | 2 – NFD with through the door operator, main circuit disconnect. Includes drive input | |
2 = | semiconductor fuses. | |
|
| |
ADDITIONAL OPTIONS |
| |
Item | Description | |
Blower Motor Starter | Select the correct blower motor amps. The value must be selected to complete | |
1 to 7 | the Order Code for order entry. | |
|
| |
Door Mounted Devices | To meet UL508A for industrial locations the | |
E = | E = | |
F = Fwd/Rev Switch 5 | F = Forward / Reverse Switch - FWD/REV Selector Switch applies to regenerative drives only. | |
H = HOA Selector Switch | H = Hand (Manual) - Off - Automatic Switch | |
J = Jog PB | ||
J = Jog Push button | ||
K = Keypad | ||
K – Keypad | ||
P = Drive Power “ON” PL | ||
R = Reset PB | P = Drive Power “ON” pilot light indicates drive running. | |
V = Analog Armature Ammeter & Voltmeter | R = Drive can be reset by means of the door mounted push button (PB), Remote (PB) or (PB) on the cover of the drive. | |
W = Analog Field Ammeter & Voltmeter | V = Analog Armature Ammeter (150%) & Voltmeter (100%). | |
| ||
| W = Analog Field Ammeter (100%) & Voltmeter (100%) | |
|
| |
Encoder Cable | The drive has a DB9 connector for encoder feedback. The encoder cable is supplied with the DB9 connector wired to a | |
Y = Encoder cable | terminal block. | |
|
|
DC MentorPak
For options not included in the Order Code configurator, please consult factory.