Emerson Packaged Drives and Engineered Systems manual 323

Page 6

www.emersonct.com

800-533-0031

Heavy Duty 230 VAC, 3-Phase Input and Output, 50/60 Hz Input

 

Heavy Duty

 

Slim Enclosure

 

 

Cube Enclosure

 

150% for 1 minute

 

 

Dimensions

Weight

 

Dimensions

Weight

HP

 

Amps

Order Code

 

Order Code

 

 

HxWxD (in)

(Ibs)

HxWxD (in)

(Ibs)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

4.3

RSxxH2001xxx-x

 

38x16x16

135

RCxxH2001xxx-x

24x16x16

65

 

 

 

 

 

 

 

 

 

 

1.5

 

5.8

RSxxH21P5xxx-x

 

38x16x16

135

RCxxH21P5xxx-x

24x16x16

65

 

 

 

 

 

 

 

 

 

 

2

 

7.5

RSxxH2002xxx-x

 

38x16x16

135

RCxxH2002xxx-x

24x16x16

65

 

 

 

 

 

 

 

 

 

 

3

 

10.6

RSxxH2003xxx-x

 

38x16x16

140

RCxxH2003xxx-x

24x16x16

70

 

 

 

 

 

 

 

 

 

 

5

 

17

RSxxH2005xxx-x

 

38x16x16

140

RCxxH2005xxx-x

24x16x16

70

 

 

 

 

 

 

 

 

 

 

7.5

 

25

RSxxH27P5xxx-x

 

38x16x16

140

RCxxH27P5xxx-x

24x16x16

70

 

 

 

 

 

 

 

 

 

 

10

 

31

RSxxH2010xxx-x

 

56x16x16

140

RCxxH2010xxx-x

30x24x16

70

 

 

 

 

 

 

 

 

 

 

15

 

42

RSxxH2015xxx-x

 

56x16x16

210

RCxxH2015xxx-x

30x24x16

145

 

 

 

 

 

 

 

 

 

 

20

 

56

RSxxH2020xxx-x

 

72x21x16

210

RCxxH2020xxx-x

39x30x16

145

 

 

 

 

 

 

 

 

 

 

25

 

68

RSxxH2025xxx-x

 

72x21x16

300

RCxxH2025xxx-x

39x30x16

200

 

 

 

 

 

 

 

 

 

 

30

 

80

RSxxH2030xxx-x

 

72x21x16

300

RCxxH2030xxx-x

39x30x16

200

 

 

 

 

 

 

 

 

 

 

Normal Duty 460 VAC, 3-Phase Input and Output, 50/60 Hz Input

Normal Duty

 

Slim Enclosure

 

 

Cube Enclosure

 

110% for 1 minute

 

 

Dimensions

Weight

 

 

Dimensions

Weight

HP

Amps

Order Code

 

Order Code

 

 

HxWxD (in)

(Ibs)

 

HxWxD (in)

(Ibs)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.5

2.8

RSxxN41P5xxx-x

 

38x16x16

135

RCxxN41P5xxx-x

 

24x16x16

70

 

 

 

 

 

 

 

 

 

 

2

3.8

RSxxN4002xxx-x

 

38x16x16

135

RCxxN4002xxx-x

 

24x16x16

70

 

 

 

 

 

 

 

 

 

 

3

5

RSxxN4003xxx-x

 

38x16x16

135

RCxxN4003xxx-x

 

24x16x16

70

 

 

 

 

 

 

 

 

 

 

5

8.8

RSxxN4005xxx-x

 

38x16x16

135

RCxxN4005xxx-x

 

24x16x16

70

 

 

 

 

 

 

 

 

 

 

7.5

11

RSxxN47P5xxx-x

 

38x16x16

135

RCxxN47P5xxx-x

 

24x16x16

70

 

 

 

 

 

 

 

 

 

 

10

15.3

RSxxN4010xxx-x

 

38x16x16

140

RCxxN4010xxx-x

 

24x16x16

70

 

 

 

 

 

 

 

 

 

 

15

21

RSxxN4015xxx-x

 

38x16x16

140

RCxxN4015xxx-x

 

24x16x16

70

 

 

 

 

 

 

 

 

 

 

20

29

RSxxN4020xxx-x

 

38x16x16

140

RCxxN4020xxx-x

 

24x16x16

70

 

 

 

 

 

 

 

 

 

 

25

35

RSxxN4025xxx-x

 

56x16x16

140

RCxxN4025xxx-x

 

30x24x16

150

 

 

 

 

 

 

 

 

 

 

30

43

RSxxN4030xxx-x

 

56x16x16

210

RCxxN4030xxx-x

 

30x24x16

150

 

 

 

 

 

 

 

 

 

 

40

56

RSxxN4040xxx-x

 

56x16x16

210

RCxxN4040xxx-x

 

30x24x16

250

 

 

 

 

 

 

 

 

 

 

50

68

RSxxN4050xxx-x

 

72x21x16

300

RCxxN4050xxx-x

 

39x30x16

280

 

 

 

 

 

 

 

 

 

 

60

83

RSxxN4060xxx-x

 

72x21x16

350

RCxxN4060xxx-x

 

39x30x16

280

 

 

 

 

 

 

 

 

 

 

75

104

RSxxN4075xxx-x

 

72x21x16

350

RCxxN4075xxx-x

 

39x30x16

280

 

 

 

 

 

 

 

 

 

 

100

138

RSxxN4100xxx-x

 

72x36x18

550

 

 

 

 

 

 

 

 

 

 

 

 

 

 

125

168

RSxxN4125xxx-x

 

72x36x18

550

 

 

n/a

 

 

 

 

 

 

 

 

 

 

150

202

RSxxN4150xxx-x

 

90x36x20

700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

236

RSxxN4200xxx-x

 

90x36x20

700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Weight does not include options.

Order string: The base Order Code requires a minimum of 12 characters in sequence to create the order string.

AC RapidPak

323

Image 6
Contents Packaged Drives Engineered Systems 319 Servo Drive lb-inRapidPaks and CustomPaks 320AC RapidPak 321Heavy Duty 208 VAC, 3-Phase Input and Output, 50/60 Hz Input 322Heavy Duty 230 VAC, 3-Phase Input and Output, 50/60 Hz Input 323324 Description325 Input Voltage 208-460-575 VAC, 50/60 HZ AC CustomPak326 CT Soft Windows based Programming ToolUL508A DC StandardPak327 MentorPak PN DEN4255AN1A0-ERegenerative 208-240-380-480 VAC, 3-Phase Input, 50/60 Hz Dimensions & Weights328 Power One Line Diagram 329DB Braking Resistor1 330 Drive Amp Rating Armature Input Power Disconnect331 Dynamic Braking DBUL508A up to 150 hp @ 240 VAC, 500 hp @ 480 VAC, 40˚ C DC CustomPak332 660 200-1500 HPDimensions Large Enclosed AC Drives333 VAC Large Enclosed Drives Horsepower Ratings 334 Create a comprehensive range of custom power systems 335Bottom 336SPM Module Descriptions Rectifier TopActive Input Regeneration 337Single Drives Pulse Input CurrentMotor Normal Duty Heavy DutyTypical OutputEngineered Systems 339Section To existing Remote PLC200V to 690V 3Ø 90V to 690V 1Ø, 3Ø 208-660V 3Ø Power distribution, Common DC bus, Speed reducers341 All major communication protocols supported

Packaged Drives and Engineered Systems specifications

Emerson Packaged Drives and Engineered Systems are leading-edge solutions designed for various applications that require reliable and efficient motor control. These systems are engineered to optimize performance across a diverse range of industries, including HVAC, water treatment, food processing, and material handling. By integrating advanced technologies, these packaged drives ensure that companies can enhance operational efficiency, reduce energy consumption, and minimize downtime.

One of the primary features of Emerson Packaged Drives is their versatility. They are designed to work seamlessly with a variety of motor types, including AC and DC motors, making them suitable for numerous applications. The systems can be easily customized to meet specific operational requirements, providing flexibility for industries that demand tailored solutions.

Another significant characteristic of Emerson's engineered systems is advanced control capabilities. The drives utilize sophisticated algorithms and embedded control features that enable precise speed, torque, and position management. This level of control not only ensures optimal performance but also enhances process reliability, which is crucial in critical applications where failure is not an option.

Energy efficiency is a cornerstone of Emerson's drive systems. By implementing variable frequency drive (VFD) technology, these packages can adjust motor speed and torque to match application requirements, leading to significant energy savings. Emerson's drives are designed with energy monitoring tools that help operators track and reduce energy usage, aligning with sustainability goals and lowering operational costs.

The integration of predictive maintenance technologies is another hallmark of Emerson Packaged Drives. By employing sensors and IoT connectivity, these drives can collect real-time data on motor performance, enabling proactive maintenance and reducing the risk of unexpected failures. This predictive approach not only extends equipment lifespan but also minimizes costly downtime and maintenance expenses.

Emerson Packaged Drives also prioritize user-friendliness. With intuitive interfaces and comprehensive diagnostic tools, operators can easily manage and troubleshoot the systems. The compact design of the drives allows for straightforward installation and integration into existing setups.

In summary, Emerson Packaged Drives and Engineered Systems stand out due to their versatility, advanced control features, energy efficiency, predictive maintenance capabilities, and user-friendly design. These attributes make them an ideal choice for industries aiming to enhance performance and efficiency, securing their position as leaders in motor control technology.