Emerson 7400 user manual Daily Checks

Page 56

Series 7400 Single Phase 1+N UPS

Chapter 5

Maintenance

5.1 Introduction

This chapter contains the procedures necessary to effect general maintenance of the UPS module and battery. Certain procedures entail gaining internal access to the UPS, and should only be undertaken by a competent engineer who is familiar with the operation and layout of the equipment and understands the areas of potential hazard. If you have any doubts concerning safety or the method carrying out any procedure then contact an approved service agent for assistance or advice. If the locally approved agent is known to you, then you should contact the Customer Services & Support department at the address shown at the front of this manual.

The manufacturer offers customer training, at a nominal fee, if required. Such training can range from a one-day operator course to in-depth training on maintenance and troubleshooting lasting several days, and can be carried out at the manufacturer’s plant or at the customer premises.

5.2 Safety Precautions

When working on the UPS remember that the equipment contains live voltages at ALL TIMES unless it is externally isolated from the mains supply, bypass supply and batteries. It is essential that the safety and precautionary notes contained throughout this manual are read and FULLY UNDERSTOOD before touching any UPS internal component part.

5.3 Scheduled Maintenance

5.3.1 Daily Checks

The UPS utilises solid-state components which are not subject to wear, with the only moving parts being the cooling fans. Scheduled maintenance requirements, beyond ensuring that the environmental conditions remain suitably cool and clean, are therefore minimal. However, a well documented periodic program of inspection and preventive maintenance, as suggested below, will help to ensure optimum equipment performance and may serve to detect certain minor malfunctions prior to them developing into a major fault.

Carry out a daily walk-by inspection of the UPS, checking the following points:

1.Carry out a spot check of the operator control panel; ensuring that all mimic LED indications are normal, all metered parameters are normal and no warning or alarm messages are present on the display panel.

2.Check for obvious signs of overheating.

3.Listen for any noticeable change in audible noise.

4.Ensure that the ventilation grills around the UPS are unobstructed.

5.If possible, log the results of the inspection, noting any discrepancies from the norm.

47

Image 56
Contents E r M a n u a l Dear Customer Emerson Network Power India Private Limited Registered and Head Office Branch Offices Safety Procedure General Operating Instructions Optional Equipment Redundant vs Non-Redundant configuration IntroductionSeries 7400 UPS Single Module Block Diagram 2 7400 Module DesignSeries 7400 UPS Isolator configurations UPS Power Switch Configuration Battery Circuit Breaker 10/ 40 kVA 60/ 70 kVA Redundancy configuration One plus One Parallel ControlSynchronisation Current sharingBattery charge current sharing Parallel control in a one-plus-one system‘Common Battery’ configuration Operator Control Panel Mimic IndicationsControl switches Switch S7 Inverter on Battery Circuit Breaker Battery Cabinet / Rack LCD DisplayGeneral Batteries Test Equipment Personnel Starting How to turn on the System from a Shut down condition Step Action ResponseHow to turn on the System from a Maint. power-down condition Isolator on both modules Following points will be live within the UPSHow to totally Power down the System Series 7400 Single Phase 1+N UPS Installation Procedure Cooling air flow ClearancesBattery Location Preliminary ChecksPage Cable Entry Cable Rating Cable Connections Cabling Procedure Ensure Correct Phase RotationConnecting the parallel interface cables I2 I3 I4 RU NU RS NS NU RU RI SI TI N2 N3 N2 U3 RI SI TI + + ve ve S C a B I N E T T T E R Y C a B I N E T Series 7400 Single Phase 1+N UPS Optional Equipment AS400 Interface Board #100215120003 Remote Control Inputs Calibration1 AS400 Interface Board Outputs SH1 4-WAY AS400 Interface Board #100201120004 Control Inputs SH1 CN1Output Interface Remote Alarms Board 100215120007 Alarm OutputsRemote Control Inputs Relay Power Supply Mimic and Alarm ConnectionsSeries 7400 Single Phase 1+N UPS Terminals of RAM Output Interface PCB Mounted in Module Series 7400 Single Phase 1+N UPS Daily Checks Weekly Checks Annual Service Extended Service Battery Maintenance Series 7400 Single Phase 1+N UPS General Troubleshooting Procedure Troubleshooting UPS systemsFault Identification Operating Parameters and LimitationsFault Reporting Corrective ActionLED Normal Actions to be Taken if Abnormal Number State LS4 Display Message Interpretation Display Panel Message InterpretationUPS on N E X U R E Inter Connection cable detailsSeries 7400 Single Phase 1+N UPS

7400 specifications

The Emerson 7400 is a state-of-the-art control system designed for industrial applications, offering enhanced performance and reliability in process automation. This robust device is a part of Emerson's larger DeltaV system, known for its scalability and flexibility in various operational environments.

One of the main features of the Emerson 7400 is its advanced control capabilities, which enable precise management of complex industrial processes. The system is built to support a wide range of control strategies, including PID control, advanced control algorithms, and model predictive control, allowing for optimized performance tailored to specific operational requirements. This versatility makes it suitable for industries such as oil and gas, chemical processing, pharmaceuticals, and more.

The Emerson 7400 utilizes cutting-edge technologies to ensure seamless integration and communication with other components within a facility. Its open architecture supports a wide array of field devices, enhancing the interoperability of the entire control system. The integration of Ethernet-based communication protocols is another notable characteristic, facilitating high-speed data transfer and real-time monitoring, streamlining operations, and improving decision-making processes.

With a focus on safety and reliability, the Emerson 7400 is designed with built-in redundancy features. These include dual power supplies and network interfaces, ensuring continuous operation even in the event of component failure. This redundancy is crucial for industries where downtime could result in substantial financial losses or safety hazards.

The user interface of the Emerson 7400 is another highlight, combining intuitive design with powerful analytics capabilities. The system offers advanced visualization tools and customizable dashboards, providing operators with critical insights into process performance and enabling proactive management of potential issues.

Furthermore, the Emerson 7400 supports industry 4.0 initiatives through data analytics and cloud integration. This allows for predictive maintenance, improving equipment longevity and reducing operational costs. The system’s data collection and analysis capabilities empower organizations to leverage big data for enhanced productivity and efficiency.

In summary, the Emerson 7400 is a sophisticated control system that brings together advanced technologies, robust features, and a commitment to operational excellence. Its reliability, adaptability, and integration capabilities position it as a leading choice for industries seeking to enhance their automation processes while ensuring safety and efficiency.