Emerson GXT2U user manual Battery Cabinet Specifications, Dimensions in mm, WEIGHT, lb kg

Page 34

Battery Cabinet Specifications

Model Number

GXT2-72VBATT

 

 

Used w/ UPS Model

GXT2-2700RT208

 

 

DIMENSIONS in (mm)

 

 

 

Unit - W x D x H in. (mm)

3.5 x 24.2 x 17 (87 x 618 x 430)

 

 

Shipping - W x D x H in. (mm)

10.5 x 27.2 x 23 (268 x 692 x 585)

 

 

WEIGHT, lb (kg)

 

 

 

Unit: lbs (kg)

93.6 (42.5)

 

 

Shipping: lbs (kg)

102.5 (46.5)

 

 

BATTERY PARAMETERS

 

 

 

Type

Valve-regulated, nonspillable, lead acid

 

 

Qty x V x Rating

2 x 6 x 12V x 9.0 AH

 

 

Battery Mfg/Part #

Panasonic/UP-VW1245P1

Yuasa/REW 45-12

Back-Up Time

See Battery Run Times charts

 

 

ENVIRONMENTAL

 

 

 

Operating Temp

+32°F to +104°F (0°C to +40°C)

 

 

Storage Temp

+5°F to +122°F (-15°C to +50°C)

 

 

Relative Humidity

0% to 95%, non-condensing

 

 

Operating Elevation

Up to 10,000 ft. (3000 m) at 104°F (40°C)

without derating

Storage Elevation

50,000 ft. (15,000 m) maximum

 

 

AGENCY

 

 

 

Safety

UL 1778, c-UL Listed

 

 

RFI/EMI

FCC Part 15, Subpart B, Class A

 

 

Transportation

ISTA Procedure 1A

 

 

30

DISCONTINUED

PRODUCT

 

Image 34
Contents Liebert GXT2U DIS Product Table of Contents Operating Instructions Important Safety Instructions DIS Glossary of Symbols Introduction Major Components Rectifier/Power Factor Correction PFC CircuitBattery Charger Transient Voltage Surge Suppression and EMI/RFI FiltersDC-to-DC Converter BatteryDynamic Bypass Liebert GXT2U-Rear View Preparation InstallationTower UPS Installation Base to accommodateRack-Mount UPS Conversion and Installation Optional rack mount handlesMounting rails M5 screwsApply grease UPS or battery cabinet Apply grease inside External Battery Cabinet Installation DIS Controls and Indicators ON/Alarm Silence/Manual Battery Test ButtonBypass Indicator LED Amber Load/Battery Level Indicators 4 Green, 1 AmberFault Indicator LED Red UPS on Indicator LED GreenOutput Voltage Selection Bypass Mode Operation Normal Mode OperationOperating Instructions Battery Mode Operation Battery Recharge ModeCommunications Interface Port Pins 4 & 5 Remote Shutdown on BatteryCommunications Pin Assignment DescriptionPins 5 & 6 Any-Mode Shutdown Auto-Enable Output Pin 6 LogicUPS Intelligent Communications Configuration Program Liebert GXT2U Configuration Program AbilitiesMaintenance Battery ReplacementInternal Battery Replacement Procedures On bypass due to DC bus overvoltage beep every 4 sec TroubleshootingOn bypass due to overtemperature condition beep every 4 sec On bypass due to PFC failure beep every 4 secTroubleshooting Guide Problem Cause SolutionBattery test is performed Alarm Conditions Condition AlarmSpecifications Dimensions in mm Battery Cabinet SpecificationsWEIGHT, lb kg Load % Battery Run TimesInternal Battery MinutesProduct Warranty Registration DIS DIS DIS Product Emerson Network Power Technical Support / ServiceLocations