Emerson GXT2U user manual Maintenance, Battery Replacement

Page 27

MAINTENANCE

The Liebert GXT2U requires very little maintenance. The batteries are valve- regulated, nonspillable, lead acid and should be kept charged to obtain their designed life. The UPS continuously charges the batteries when connected to the utility supply.

When storing the UPS for any length of time, it is recommended to plug the UPS in for at least 24 hours every four to six months to ensure full recharge of the batteries.

The Liebert GXT2U is designed to allow the user to safely replace the internal batteries. Read the safety cautions before proceeding. Contact your local dealer or Liebert representative to obtain the appropriate replacement battery kit part number and pricing.

Battery Replacement

! CAUTION

A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed before replacing the batteries:

Remove rings, watches, or other metal objects.

Use a Phillips (crosshead) screwdriver with insulated grips.

Do not lay tools or other metal objects on top of the batteries.

If the battery replacement kit is damaged in any way or shows signs of leakage, contact your local dealer or Liebert representa- tive immediately.

Do not dispose of batteries in a fire. The batteries may explode.

23

DISCONTINUED

PRODUCT

 

Image 27
Contents Liebert GXT2U DIS Product Table of Contents Operating Instructions Important Safety Instructions DIS Glossary of Symbols Introduction Transient Voltage Surge Suppression and EMI/RFI Filters Rectifier/Power Factor Correction PFC CircuitBattery Charger Major ComponentsBattery DC-to-DC ConverterDynamic Bypass Liebert GXT2U-Rear View Base to accommodate InstallationTower UPS Installation PreparationOptional rack mount handles Rack-Mount UPS Conversion and InstallationM5 screws Mounting railsApply grease UPS or battery cabinet Apply grease inside External Battery Cabinet Installation DIS ON/Alarm Silence/Manual Battery Test Button Controls and IndicatorsUPS on Indicator LED Green Load/Battery Level Indicators 4 Green, 1 AmberFault Indicator LED Red Bypass Indicator LED AmberOutput Voltage Selection Normal Mode Operation Bypass Mode OperationOperating Instructions Battery Recharge Mode Battery Mode OperationPin Assignment Description Pins 4 & 5 Remote Shutdown on BatteryCommunications Communications Interface PortAuto-Enable Output Pin 6 Logic Pins 5 & 6 Any-Mode ShutdownUPS Intelligent Communications Liebert GXT2U Configuration Program Abilities Configuration ProgramBattery Replacement MaintenanceInternal Battery Replacement Procedures On bypass due to PFC failure beep every 4 sec TroubleshootingOn bypass due to overtemperature condition beep every 4 sec On bypass due to DC bus overvoltage beep every 4 secProblem Cause Solution Troubleshooting GuideBattery test is performed Condition Alarm Alarm ConditionsSpecifications Battery Cabinet Specifications Dimensions in mmWEIGHT, lb kg Minutes Battery Run TimesInternal Battery Load %Product Warranty Registration DIS DIS DIS Product Technical Support / Service Emerson Network PowerLocations