Operating Instructions

Bypass Alarm Mode: Allows the user to enable/dis- able alarm, indicating that the bypass is not quali- fied.

Bypass Alarm Mode

>Enable Disable

Guarantee Shutdown: Allows the user to guarantee a shutdown after a low battery warning is announced, even if the utility becomes qualified.

Guarantee Shutdown

Enable

* Disable

Intelli-Battery Ca.: Allows the user to enter the quantity of intelligent battery cabinets installed.

Enter Intelli- Battery cabinet count

x

Air Filter Reminder: Allows the user to set a warn- ing reminder to check the air filters.

Air Filter Reminder

2weeks

4weeks

10weeks

26weeks

52weeks

*Disable

Line Compensation: Allows the user to control the amount of line drop compensation to be applied to the nominal output voltage. Line drop compensation is intended to compensate for any IR drop that may occur when the UPS is a significant distance from the protected load.

Output Volt: x

Increase Decrease ESC to cancel

to Accept & Exit

Factory Defaults: Allows the user to reset all set- tings to the values in effect when the UPS was shipped from the factory.

Load Factory Default

Are you sure?

Press for yes

Press ESC for no

26

Image 30
Contents Nfinity Power System Page Table of Contents Figures Important Safety Instructions Glossary of Symbols System Description FeaturesGeneral Description Standard ComponentsNfinity weight and dimensions Front and back viewsAuto Restart Mode Normal ModeBackup Mode Bypass ModeUser Interface Module Major ComponentsUnit Frame System Control ModulePower Module Battery ModuleEnvironment Required Setup EquipmentInspection Site PreparationUnloading Unloading the UPSStationary Mounting Cable Installation Wiring PreparationConfiguring the Bypass Voltage TB2 Input Wiring TB1 Output Wiring TB3Grounding Conductor Installation Connecting to External Panel Boards Bypass Voltage Jumper Position TB2Setup 3 240 VAC Setup 1 208 VACSetup 2 120 VAC 208 VACRepo switch connections Repo ConnectionCOM1 Relay Contacts CommunicationsCOM Ports COM2 SerialDisplay Controls Controls and IndicatorsFault/Warning and Status LEDs ButtonsStatus LED Modes Navigating the MenuManual Transfer to Bypass Operating ProceduresStart-Up and Initialization Shutting Down the UPSMain Menu UPS Status Event Log Module ReplacementUPS Configuration Active Alarms Service Tools Display Date/TimeUPS Status Screen UPS Configuration Screen Review Settings Change Configuration Settings Change Settings Menu Change SettingsInterval Auto Restart ModeAuto Restart Delay Start DaySet Date/Time DST ModeAlarm Mode ThresholdGuarantee Shutdown Enable UPS Configuration Screen Service Mode Menu Service ModeDisplay Date/Time Active Alarms Event LogTransfer to Bypass Module Replacement Service Tools for Liebert Global Services Engineers Clear FailuresActive Alarms User Interface Text Cause ActionOperation Module LED Indication Power ModuleBattery Module Guide to LEDs Control ModuleModule Replacement Removing ModulesAdding or Replacing Modules Replacing the User InterfaceProper Care MaintenanceScheduled Maintenance Replacing Fan FiltersProduct Warranty Registration SpecificationsSpecifications Page Technical Support/Service Company Behind the ProductsLocations