Emerson 00825-0100-4075 manual IECEx Certifications

Page 23

Quick Installation Guide

00825-0100-4075, Rev BA February 2010

Smart Wireless THUM Adapter

IECEx Certifications

I7 IECEx Intrinsic Safety

Certificate No.: IECEx BAS 09.0050X

Ex ia IIC T4 (-50 °C Tamb 70°C)

IP66

Table 3. Input Parameters

Loop Power

Ui = 30V

Ii = 200 mA

Pi = 1.0 W

Ci = 0

Li = 0

Special conditions for safe use (X)

The surface resistivity of the antenna is greater than one gigaohm. To avoid electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth.

The enclosure is made of aluminium alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if located in a zone 0.

N7 IECEx Type n

Certificate No.: IECEx BAS 09.0058

Ex nA IIC T4 (-50 °C Tamb 70°C)

Ui = 45 Vdc MAX

IP66

23

Image 23
Contents Quick Installation Guide Smart Wireless Thum AdapterImportant Notice Conduit Entry Wireless ConsiderationsPower Up Sequence Thum Adapter PositionLoad Resistor Bench TOP ConfigurationPower Supply Direct Mount Physical InstallationRemote Mount Remote MountWiring Diagrams Remote Mount Wiring Diagram for 2-Wire Device Remote Mount Wiring Diagram for 2-Wire Device with Resistor Remote Mount Wiring Diagram for 4-Wire Passive Device Green Black Remote Mount Wiring Diagram for 4-Wire Active Device Power+ GroundResistor Power + Ohm Resistor Junction Box Field Communicator Device Network ConfigurationAMS AMS Loop Current TestAMS Configure screen Field Communicator Smart Wireless GatewayAMS Wireless Configurator Verify OperationReference Information TroubleshootingProduct Certifications European Directive InformationHazardous Locations Certificates North American CertificationsCSA Canadian Standards Association European CertificationsIECEx Certifications EC Declaration of Conformity EC Declaration of Conformity Atex Notified Bodies for EC Type Examination Certificate Smart Wireless Thum Adapter Smart Wireless Thum Adapter