2.2 Safety Precautions

To avoid potential video and/or keyboard problems when using these products:

¥If the building has 3-phase AC power, ensure that the computer and monitor are on the same phase. For best results, they should be on the same circuit.

¥Use only BLACK BOX-supplied cable to connect computers and KVM switches.

To avoid potentially fatal shock hazard and possible damage to equipment, please observe the following precautions:

¥Do not use a 2-wire extension cord in any BLACK BOX product conÞguration.

¥Test AC outlets at the computer and monitor for proper polarity and grounding.

¥Use only with grounded outlets at both the computer and monitor. When using a backup power supply (UPS), power the computer, the monitor and the appli- ance off the supply.

NOTE:

The AC inlet is the main disconnect.

10

Image 12
Contents April Page Welcome to the ServSwitch Family Servswitch FamilyServselect II INSTALLER/USER Guide European Union Declaration of ConformityCompliance Statements Japanese Compliance Statement Other Agency ApprovalsNormas Oficiales Mexicanas NOM Electrical Safety Statement Instrucciones DE SeguridadNOM Statement Contents Specifications SpecificationsFeatures and Benefits Server Access ModulesIntroduction Multiplatform supportIntroduction Safety Precautions Example ServSelect II ConfigurationRack mount safety considerations Installation Getting StartedRack Mounting Your ServSelect Supplied with the ServSelectInstallation To install the 1U switch mounting bracketInstalling the ServSelect Basic ServSelect II ConfigurationSetting Up Your ServSelect II System To connect an SAM to each serverTo connect local peripherals To access the Main dialog box Basic OperationsControlling Your System at the Analog Ports Viewing and Selecting Ports and ServersOSD Status Symbols Viewing the status of your applianceSelecting servers Basic OperationsSoft switching To configure servers for soft switchingTo soft switch to a server Navigating the OSD OSD Navigation BasicsConfiguring the OSD Setup Features to Manage Routine Tasks for Your ServersTo access the Setup menu To access the Names dialog box Assigning server namesTo assign names to servers To access the Devices dialog box Assigning device typesTo access the Menu dialog box Changing the display behaviorTo assign a device type To choose the default display order of servers To set a Screen Delay Time for the OSDControlling the status flag To access the Flag dialog box To determine how the status flag is displayedSetting console security To access the Security dialog boxTo set or change the password To password protect your console To remove password protection from your consoleTo enable the screen saver mode with no password protection To log in to your consoleTo exit the screen saver mode Displaying Version InformationTo turn off the screen saver To immediately turn on the screen saverClick X to close the SAM Version dialog box Scanning Your System To add servers to the scan listTo start the scan mode To cancel scan modeTo remove a server from the scan list To access the Broadcast dialog box Broadcasting to ServersChanging Your Switch Mode To broadcast to selected serversTo turn broadcasting off To access the Switch dialog box To enable sharingTroubleshooting TroubleshootingCalling Black BOX Shipping and PackagingFlash Upgrades Possible error conditionsItems needed for the upgrade To upgrade firmwareFlash Upgrades To simultaneously upgrade multiple SAMsUpgrading the SAM firmware To upgrade SAM firmware individually Version Dialog BoxSAM Load Dialog Box Servselect II INSTALLER/USER Guide Page Page Page Doc. No -330-001A