SERVSWITCH™ BRAND FIBER KVM EXTENDERS

5.2 Connecting a CPU or KVM Switch to the Local Module

NOTE

In the universal directions in this section and in Section 5.3, we’ll sometimes refer to separate keyboard and mouse connections even though there will only be one keyboard/mouse connection when the Sun Extender (ACS236A) is involved.

Your ServSwitch Brand Fiber KVM Extender comes with a KVM-extension cable that you can use to connect a computer CPU or ServSwitch family KVM switch to the Extender’s Local Module:

The extension cable that comes with the ACS235A is a three-strand cable. The two outside strands carry keyboard and mouse data, and have 6-pin mini-DIN male connectors at both ends. The central strand carries video data; it has an HD15 female connector at the Extender end and an HD15 male connector at the other end.

The extension cable that comes with the ACS236A is a two-strand cable. The outside strand carries keyboard and mouse data, and has 8-pin mini-DIN male connectors at both ends. The central strand carries video data; it has an HD15 female connector at the Extender end and an HD15 male connector at the other end. (If you’re using the ACS236A with a legacy Sun CPU that outputs Sun video on a 13W3 connector, you’ll need a Sun video-extension cable such as product code EVMVDT02-MF to take the place of the included cable’s video strand. Important note: Do not use a standard HD15-to-13W3 “Sun video adapter” or “Sun video adapter cable” to patch the included cable’s video strand to the CPU! These are not pinned correctly for use with the Extender!)

Take these steps (making sure the CPU or KVM switch is turned OFF):

1A. ACS235A: Take the end of the included KVM-extension cable with the female video connector and plug its connectors into the matching connectors on the front panel of the Extender’s Local Module. Attach the cable’s video strand to the Module’s HD15 male connector, the cable’s keyboard strand to the 6-pin mini-DIN female connector on the Module labeled with the picture of a keyboard, and the cable’s mouse strand to the 6-pin mini-DIN female connector on the Module labeled with the picture of a mouse.

1B. ACS236A: Take the female end of the included KVM-extension cable’s video strand, or of your Sun video-extension cable, and plug it into the matching male video connector (HD15 for VGA, 13W3 for Sun video) on the front panel of the Extender’s Local Module. (Do not plug video cables into both video connectors at the same time!) Plug the keyboard/mouse strand of the included KVM-extension cable into the Local Module’s 8-pin mini-DIN female keyboard/mouse connector.

32

Image 83
Contents ACS235A ACS236A Welcome to the ServSwitchTM Family Servswitch Brand Fiber KVM Extenders RADIO-FREQUENCY Interference Statements Servswitch Brand Fiber KVM Extenders NOM Statement Contents Table of Contents Cable SpecificationsSpecifications Temperature Overview IntroductionComplete Package Configuring for RGB Video Configuring the ACS235AImportant Notes Jumper Settings Locations of the ACS235A Local Module’s jumpers Setting the Jumpers in the Local Module OptionalSetting the VGA/RGB jumpers Setting VGA-to-RGB jumper JP2 Locations of the ACS235A Remote Module’s jumpers Setting the Jumpers in the Remote Module OptionalSync-on-color jumpers and diodes Setting gain-control jumper bank JP8 Setting Vsync jumper JP9 Configuring the ACS236A Locations of the ACS236A Local Module’s jumpers Setting video-handling jumpers JP2 and JP10 Locations of the ACS236A Remote Module’s jumpers Setting gain-control jumper bank JP8 Setting Vsync jumper JP9 Guidelines and Limitations for Attaching Equipment Installation1 CPU Keyboard and Mouse Connecting a CPU or KVM Switch to the Local Module Installation Servswitch Brand Fiber KVM Extenders Installation Running Fiber Cable Between the Local and Remote Modules Powering Up the Rest of the System Connecting Power to the Local and Remote ModulesInterpreting the Remote Module’s 7-Segment Display OperationOperation Servswitch Brand Fiber KVM Extenders Things to Try First TroubleshootingShipping and Packaging Calling Black BoxAppendix a Pinouts Connectors on Both ModelsConnectors on the ACS235A Pin Signal Direction Signal Pin Connectors on the ACS236ASignal Direction Figure B-1. The RMK235 Rackmount Kit Appendix B Rackmounting the ExtenderFigure B-2. The rackmount assembly RMK235 shown Customer Support Information Welcome to the ServSwitchTM Family Servswitch Brand Fiber KVM Extenders RADIO-FREQUENCY Interference Statements Servswitch Brand Fiber KVM Extenders NOM Statement Contents Table of Contents Specifications Specifications Connectors ACS236A Introduction Complete Package Configuring the ACS235A Important Notes Jumper Settings Setting the Jumpers in the Local Module Optional Setting the VGA/RGB jumpers Setting VGA-to-RGB jumper JP2 Setting the Jumpers in the Remote Module Optional Sync-on-color jumpers and diodes Setting gain-control jumper bank JP8 Setting Vsync jumper JP9 Configuring the ACS236A Locations of the ACS236A Local Module’s jumpers Setting video-handling jumpers JP2 and JP10 Setting the Jumpers in the Remote Module Optional Setting gain-control jumper bank JP8 Setting Vsync jumper JP9 Installation 1 CPU Keyboard and Mouse Connecting a CPU or KVM Switch to the Local Module Installation Servswitch Brand Fiber KVM Extenders Installation Running Fiber Cable Between the Local and Remote Modules Connecting Power to the Local and Remote Modules Operation Operation Servswitch Brand Fiber KVM Extenders Troubleshooting Calling Black Box Appendix a Pinouts Connectors on the ACS235A Pin Signal Direction Connectors on the ACS236A Signal Direction Appendix B Rackmounting the Extender Figure B-2. The rackmount assembly RMK235 shown Page