IBM P5 570 manual 3 p5 Customer-Managed Microcode, Service Update Management Assistant

Page 74

checks the current customer service status from the IBM entitlement database; if this reveals that you are not under warranty or MA, then the service call is refused and posted back using e-mail.

Service focal point

Service Focal Point is used by service technicians to start and end their service calls. It provides service representatives with event, Vital Product Data (VPD), and diagnostic information. The HMC can also notify service representatives of hardware failures automatically by using the Service Agent features. You can configure the HMC to use the Service Agent call-home feature to send IBM event information. This information is stored, analyzed, and then acted on by the service representative. Some parts of Service Focal Point have to be configured so that the proper information is sent to IBM.

You can download the latest version of Service Agent at:

ftp://ftp.software.ibm.com/aix/service_agent_code

3.3.3 p5 Customer-Managed Microcode

The pSeries and RS/6000 Customer-Managed Microcode is a methodology that enables you to manage and install microcode updates on p5, pSeries, and RS/6000 systems and associated I/O adapters. The IBM pSeries Microcode Update Web site can be found at:

http://techsupport.services.ibm.com/server/mdownload

IBM provides service tools that can assist in determining microcode levels and updating systems with the latest available microcode. To determine which tool to use in a specific environment, visit:

http://techsupport.services.ibm.com/server/mdownload/mcodetools.html

3.3.4 Service Update Management Assistant

The Service Update Management Assistant (SUMA) helps system administrators retrieve maintenance updates from the Web. SUMA offers flexible options that enable customers to set up policies to automate the download of fixes to their systems. SUMA policies can be scheduled to periodically check the availability of specific new fixes (APAR, PTF, or fileset), critical or security fixes, or an entire maintenance level. A notification e-mail can be sent detailing updates that are needed when comparing available fixes to installed software, a fix repository, or a maintenance level.

Benefits provided by SUMA include:

￿Moves administrators away from the task of manually retrieving maintenance updates from the Web

￿Policy can be scheduled to run periodically; for example, download the latest critical fixes weekly

￿Can compare fixes needed against software inventory, fix repository, or a maintenance level

￿Receive mail notification after a fileset preview or download operation

￿Allows for FTP, HTTP, or secure HTTPS transfers

￿Provides same requisite checking as the IBM fix distribution Web site

￿Available through SMIT menus (smitty suma) or a command line interface

62p5-570 Technical Overview and Introduction

Image 74
Contents IBM Eserver p5 Technical Overview Introduction Page IBM Sserver p5 570 Technical Overview Introduction First Edition July Contents Page Page Vi p5-570 Technical Overview and Introduction Vii Trademarks Preface Team that wrote this RedpaperBecome a published author Comments welcomeGeneral description P5-570 Technical Overview and Introduction System specifications Physical packageMinimum and optional features View from the frontProcessor card features Processor card FC DescriptionMemory features Disk and media featuresModel D10 I/O drawer USB diskette drive5 I/O drawers Model D10 I/O drawer physical package Model D11 I/O drawer Model D20 I/O drawerDrawers and usable PCI slots Model D20 I/O drawer physical packageValue Paks Hardware Management Console modelsModel type conversion System racksIBM RS/6000 7014 Model T00 Enterprise Rack Rack-mounting rules for p5-570 and I/O drawers AC Power Distribution Unit and rack contentIBM RS/6000 7014 Model T42 Enterprise Rack Additional options for rack Flat panel display optionsIBM 7212 Model 102 TotalStorage Storage device enclosure OEM rackHardware Management Console 7310 Model CR2 Statement of direction 18 p5-570 Technical Overview and Introduction Architecture and technical overview POWER5 chip POWER4 POWER5Simultaneous multi-threading Dynamic power managementEnhanced SMT features ST operationPower chip evolution POWER4Processor cards CMOS, copper, and SOI technologyProcessor drawer interconnect cables Processor card with DDR1 memory socket layout viewProcessor clock rate Pmcycles -mMemory restriction Memory placement rulesMemory subsystem RIO-2 buses and GX+ card System busesMemory throughput PCI-X slots and adapters Internal I/O subsystemSP bus Scsi adapters LAN adaptersGraphic accelerators Bit and 32-bit adaptersInternal storage Internal hot swappable Scsi disksHot-swap disks and Linux Internal RAID optionsInternal media devices 2 7311 Model D10 and 7311 Model D11 I/O drawers External I/O subsystems1 I/O drawers 3 7311 Model D20 I/O drawer Model D10 featuresModel D11 features 4 7311 I/O drawer and RIO-2 cabling Model D20 internal Scsi cabling5 7311 I/O drawer and Spcn cabling Cost Optimized Performance OptimizedExternal disk subsystems IBM 2104 Expandable Storage PlusIBM TotalStorage Enterprise Storage Server IBM 7133 Serial Disk Subsystem SSAIBM TotalStorage FAStT Storage servers Virtualization Advanced Power Virtualization featureDynamic logical partitioning Virtual Ethernet15shows the POWER5 partitioning concept Micro-Partitioning technologyPOWER5 Partitioning Virtual I/O ServerService processor Partition Load ManagerService processor base Service processor extenderBoot process IPL flow without an HMC attached to the systemHardware Management Console IPL flow with an HMC attached to the systemProfiles Definitions of partitionsManaged systems Specific partition definitions used for Micro-Partitioning System Management ServicesHardware requirements for partitioning Boot options 17 System Management Services main menuAdditional boot options DVD-ROM, DVD-RAMAIX 5L Operating system requirementsSecurity Linux Linux supportCapacity on Demand, RAS, and manageability Way 1.9 GHz POWER5 processor card with DDR1 memory slots Processor Capacity Upgrade on Demand methodsWay 1.65 GHz POWER5 processor card Way 1.9 GHz POWER5 processor card with DDR2 memory slotsCapacity Upgrade on Demand for memory How to report temporary activation resources Capacity Upgrade on Demand for memory feature codesTrial Capacity on Demand Reliability, availability, and serviceabilityFault avoidance Mutual surveillance First Failure Data CapturePermanent monitoring Environmental monitoring Memory reliability, fault tolerance, and integritySelf-healing Resource deallocation Fault masking5 N+1 redundancy Dynamic or persistent deallocationServiceability Error indication and LED indicatorsAdvanced System Management Interface Concurrent MaintenanceManageability Service Agent Advanced System Management main menu3 p5 Customer-Managed Microcode Service Update Management AssistantService focal point Cluster CSM value points CSM V1.4 on AIX and Linux planned 4Q04IBM Redbooks Other publicationsOnline resources How to get IBM Redbooks Help from IBM68 p5-570 Technical Overview and Introduction Page IBM Eserver p5 Technical Overview Introduction

P5 570 specifications

The IBM P5 570 is a high-performance server that was designed for enterprise-scale computing, offering a blend of advanced technologies and a flexible architecture. Launched as part of IBM's Power5 server line, the P5 570 stands out for its robust processing capabilities and extensive scalability, making it a preferred choice for businesses requiring reliable and efficient computing solutions.

At the heart of the P5 570 is the IBM Power5 processor, which employs simultaneous multi-threading (SMT) technology. This allows the processor to handle two threads per core, effectively doubling the throughput for workloads ideally suited to multi-threading. The server typically features a configuration of up to 32 Power5 processors, providing an impressive compute power that supports demanding applications, ranging from databases to complex enterprise resource planning (ERP) systems.

The P5 570 architecture supports a wide range of memory configurations, with a maximum memory capacity of up to 512 GB. Utilizing IBM’s proprietary Chip Memory technology, it can deliver high bandwidth and low latency, significantly enhancing performance for memory-intensive applications. Furthermore, the integrated memory controller architecture optimizes memory access, ensuring that critical workloads run smoothly.

Scalability is a key characteristic of the P5 570, with the ability to expand processing power and memory capacity as an organization’s needs grow. The server supports various operating systems, including AIX, Linux, and IBM i, which provides flexibility for diverse IT environments. This versatility ensures that companies can run their preferred applications without the need for substantial system overhauls.

In terms of storage, the P5 570 utilizes advanced RAID technology and supports a variety of disk configurations, ensuring that data integrity and availability are maintained. Coupled with built-in security features, such as the IBM Trusted Foundation, which establishes a secure boot environment, the P5 570 offers a reliable platform for mission-critical workloads.

Finally, the IBM P5 570 is designed for high availability and redundancy. Features like hot-swappable components and advanced error detection and recovery mechanisms minimize downtime, making it a dependable choice for businesses that operate around the clock. Combined with its powerful hardware and versatile software support, the IBM P5 570 remains a formidable player in the high-performance server arena.