Display LEDs
There are three main indicator LEDs on the front of the XG2000: Power LED, Alarm LED, and Status LED. The following explains the LED display under various conditions.
| XG2000 Condition |
| LED |
| |
|
|
|
| ||
| Power | Alarm | Status | ||
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
Off |
|
| Off | Off | Off |
|
|
|
|
|
|
Starting up |
| Power just turned on | On | Off | Off |
|
|
|
|
|
|
|
| System starting up | On | Off *1 | Blinking |
|
|
|
|
|
|
|
| System | On | Off *1 | On |
|
|
|
|
|
|
Operable |
|
| On | Off *1 | On |
|
|
|
|
|
|
After shutdown |
|
| Off | On | Off |
|
|
|
|
|
|
*1: If the XG2000 is operating normally.
If a problem occurs, the front panel LEDs and the LEDs on the individual parts can be used to identify the trouble:
XG2000 Condition |
|
| LED |
| ||
|
|
|
|
| ||
Power | Alarm | Status |
| LED on failed part | ||
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Problem | Startup error | On | Blinking |
| ||
detected |
|
|
|
|
|
|
Rear fan error | On | On |
| Rear Fan LED: Orange | ||
|
| |||||
|
|
|
|
|
|
|
| Power fan error | On | On |
| Power Supply LED: Orange | |
|
|
|
|
|
|
|
| No AC supply *2 | On | On |
| Power Supply LED: Orange | |
|
|
|
|
|
|
|
| Power supply error | On | On |
| Power Supply LED: Orange | |
|
|
|
|
|
|
|
| Voltage error | On | On |
| ||
|
|
|
|
|
|
|
| Temperature error | On | On |
| ||
|
|
|
|
|
|
|
| System dump in | On | On |
| ||
| progress |
| ||||
|
|
|
|
|
| |
|
|
|
|
|
|
|
*2: Only detectable and indicated when two power supply units are installed and connected to separate, independent power supplies.
*3: Condition of the Alarm LED will depend on the state of the system.
*4: Condition of the Status LED will depend on the state of the system.
Note that the XG2000 will shut itself off when the Temperature error is detected.
Any problems other than those that occur during start up are recorded in the event log. For details of the event log, refer to the "XG2000 User’s Guide".