Fujitsu XG2000 manual Fix the nuts and rails to the rack posts

Page 29

2. Fix the nuts and rails to the rack posts.

First, choose nuts, cage nuts or rack nuts, by the type of hole dug in the rack post.

When the rack has square post holes, cage nuts are used. When round holes, rack nuts are used.

[When the rack has square post holes]

Rack Post

Rack Screws (Large)

 

Cage Nuts

 

Rack Screws

2

 

(Large)

Rack Post

Rail L

Rack Post

 

 

 

Refer to Detail A

Rail R

 

Cage Nuts

 

 

Cage Nuts

 

Spring lugs at the top and bottom

 

Rack Post

 

Cage Nuts

Detail A

[When the rack has round post holes (top of view)]

 

Rack Post

 

Rack Post

Rail L

 

 

 

 

Cage Nut

Rack Screw

 

Detail C

 

(Large)

Cage Nut

Rack Post

 

 

 

Detail B

 

 

 

Refer to Detail B

 

Front

Refer to Detail C

 

 

 

 

<<Top of View>>

 

Installation Procedure

27

Image 29
Contents XG2000 Hardware Guide Page Preface For Safe Use of the XG2000 For Safe Use of the XG2000Not used properly XG2000 is not used properly For security No self maintenanceSafety precautions Electromagnetic compatibility USA SafetyElectromagnetic compatibility Canada Electromagnetic compatibility EULaser safety High safetyTargeted reader and expected knowledge About This ManualOrganization Related manualsProduct Information Symbols used in this manualTrademarks and abbreviations used in this manual About This Manual Contents Chapter Troubleshooting Installation CD-ROM 1Parts ListParts List XG2000 front 2XG2000 ComponentsXG2000 rear LED Display LEDs3Labels CSA/CE Label FCC LabelFCC Canada Label MAC Label Product nameplateProduct ID Label Xxxxxxxxxxxx+14 Installation and Operation 1Installation Overview Space requirements 2Installation ProcedureInstallation requirements Take the XG2000 out of its box Installing the XG2000 in a rackSet up requirements Fix the nuts and rails to the rack posts When the rack has round post holes top of viewWhen the rack has round post holes Slide the XG2000 into the rack and fasten it in place Fix the four rack mounting brackets to the XG2000Slide the XG2000 forward, and remove it from the rack Uninstalling the XG2000 from a rackThis completes the rack installation procedure Install the XPF module in the XG2000 3Installation of XFP modulesInstalling the XFP modules Uninstall the XPF module from the XG2000 Uninstalling the XFP modulesConnect the fiber optic cables to the XG2000 Connecting the fiber optic cables4Cable Connection Connect the power cords to the XG2000 Connecting the power cordsTurning the XG2000 off 5Basic OperationTurning the XG2000 on Installation and Operation Troubleshooting Alarm LED lights, but the XG2000 does not start up 1Start-up ProblemsXG2000 does not turn on Status LED blinks, but the XG2000 does not start up2Hardware Problems Troubleshooting Appendix Installation Specifications Appendix-ASpecificationsProduct Specifications XG2000 Hardware Guide