Connecting to System

Xerox FS 3270, User's Guide

Keep the settings printout together with this manual for future reference.

Settings Printout at Power-on (PCL mode only)

A settings printout can also be generated at power-on by activating function Y120.

NOTE:

The Rotary Switch has to be activated at power on in order to change from FSL to PCL or back.

2.4.2. Timeout

The Xerox FS 3270 enables printer sharing between the system and a PC. For this purpose it is possible to specify a timeout period.

If the printer is receiving input on the parallel port, for example, and there is a break in the transmission of data, the other input ports will not be polled for the period speci fied.

The factory default timeout is 20 seconds. The timeout may be changed to suit your requirements. This is done by sending a new setup to the Xerox FS 3270 input port where you want it to take effect. See Chapter 5.

Specifying Timeout.

When specifying the timeout it is also possible to specify a user string. A user string may be used for changing from one symbol set (e.g. Roman 8) to another (e.g. IBM -PC8), for example.

NOTE:

Settings on the coax input port are automatically reestablished after another input port has been using the printer.

On the parallel and RS input port, you have to program the required setup yourself.

For more detailed information on the commands required, see Chapter 4, Specifying Timeout.

- 17 -

Image 17
Contents Trademarks EMC directiveSeptember PrefaceRelated Manuals Table of Contents Table of Contents Xerox FS 3270, Users Guide PCL Driver Default Driver Installation RequirementsIntroduction to Xerox FS PCL or FSL output driverNon-IPC Xerox FS 3270 FeaturesXerox FS Supported Control UnitsItems Supplied IPC Upgrade Kit Changing Paper Size Default US/EuropeOperating Environment Xerox FS 3270 IPCInstallation Requirements Xerox FS 3270, Users Guide Rear Panel Installation and Connections of the Xerox FSSerial input Changing the Printer DriverUpgrading to IPC Connecting the Xerox FS 3270 to the PrinterConnecting via RS-232 output Connecting via Centronics outputConnecting to System Xerox FS 3270, Users Guide What if the CU Indicator fails to turn on? Connecting the Xerox FS 3270 to the SystemPCL driver TestingSettings Printout at Power-on PCL mode only TimeoutOperation of Xerox FS Indicators of the Xerox FSCU Contact with Control Unit PAR Parallel inputReady Printer Ready SER Serial input??character Specifying Timeout??%%Y100,30,1B,45%%X1 IdaSetup IPC Programming Printer IRQ HandlingProgramming Xerox FS 3270 non-IPC PCL Driver DefaultSetup Functions Supported in PCL mode Where % is the defined ESC character Send Logo ESC FeaturesWhere % is the defined ESC character Test functions T-Functions User Settings Functions X-FunctionsEngineering Functions FunctionsSetup Functions Supported in FSL mode ESC Features User Settings Functions X-Functions ??%%Y249,PASSWORD%%Y100,10,’SHARESTRING’%%X1 FSL Setup via Xerox FS 3270 Serial or Parallel Port??%%Y100,10,’SHARESTRING’%%X1 Character conversionDeactivating the Y249 Engineering Function Limitations when Y249 is activeActivating the Y249 Engineering Function Updating Firmware Recoverable Errors Error MessagesNot in engineering mode Non-Recoverable Hardware Errors PCL Test Printout Busy TimeoutTest Printouts Active Gfid = Gfid CPI=Proportionally Spaced = FSL Test Printout FSL N/S Appendix a Quick Reference Guide to FSL FunctionsLPI LPI FSL N/SEbcdic =PCL Y10=FSL Are wrapped Y12Y13 Y22 Y19FF after Y26,n1% = No FF Y35 Y41 EABY39 Y47 IRQEEPROM/RAM ESCEeprom Y52Y54 Y53Y55 Y56HEX Y71Y74 FSL mode PCL modeAscii HEX N2dataAPL Y79Name Syntax Parameters Deviations Y92 Y91Y93 Y94APO Y96Y98 Y112 Y110Y111 Y114 Y113Y115 Y118RAM Re. T2Data Example Cable connections to HP LaserJet Appendix B Using Serial OUTUse of Xerox FS 3270 serial port Appendix C Selected Xerox Products