Xerox FS 3270 instruction manual Specifying Timeout, ??character

Page 20

Specifying Timeout

Xerox FS 3270, User's Guide

4. Specifying Timeout

In order to specify the timeout for a specific input port, an FSL ( Function Selection via the Line) sequence must be sent to the port in question. To do this a temporary Escape (ESC) Character must be defined first. This is done in the following way:

&&??<character>

The sequence "&&??%" will define "%" as the ESC Character.

Timeout is specified in FSL Function 100 . This function has the following syntax ("%" is the ESC Character):

%Y100,<timeout>[,user string]%

Factory default = 20 seconds

Timeout:

0 to 255 indicating number of seconds

User string: Optional - string in HEX to be sent to the printer before transmission of data, when the printer is selected by the share unit.

If function 100 is sent to the coax, a user string number can be defined instead of a HEX string. The user string then has to be defined in function 61.

NOTE:

The Timeout string must be written in ONE line (see example overleaf).

The user string and settings will only be sent if a share condition has occurred.

- 20 -

Image 20
Contents EMC directive TrademarksSeptember PrefaceRelated Manuals Table of Contents Table of Contents Xerox FS 3270, Users Guide Installation Requirements PCL Driver Default DriverIntroduction to Xerox FS PCL or FSL output driverXerox FS 3270 Features Non-IPCXerox FS Supported Control UnitsItems Supplied Changing Paper Size Default US/Europe IPC Upgrade KitOperating Environment Xerox FS 3270 IPCInstallation Requirements Xerox FS 3270, Users Guide Installation and Connections of the Xerox FS Rear PanelChanging the Printer Driver Serial inputConnecting the Xerox FS 3270 to the Printer Upgrading to IPCConnecting via Centronics output Connecting via RS-232 outputConnecting to System Xerox FS 3270, Users Guide Connecting the Xerox FS 3270 to the System What if the CU Indicator fails to turn on?Testing PCL driver Timeout Settings Printout at Power-on PCL mode onlyIndicators of the Xerox FS Operation of Xerox FSCU Contact with Control Unit PAR Parallel inputSER Serial input Ready Printer ReadySpecifying Timeout ??character??%%Y100,30,1B,45%%X1 IdaSetup IPC Programming IRQ Handling PrinterPCL Driver Default Programming Xerox FS 3270 non-IPCSetup Functions Supported in PCL mode Where % is the defined ESC character Send Logo ESC FeaturesWhere % is the defined ESC character User Settings Functions X-Functions Test functions T-FunctionsEngineering Functions FunctionsSetup Functions Supported in FSL mode ESC Features User Settings Functions X-Functions FSL Setup via Xerox FS 3270 Serial or Parallel Port ??%%Y249,PASSWORD%%Y100,10,’SHARESTRING’%%X1??%%Y100,10,’SHARESTRING’%%X1 Character conversionDeactivating the Y249 Engineering Function Limitations when Y249 is activeActivating the Y249 Engineering Function Updating Firmware Error Messages Recoverable ErrorsNot in engineering mode Non-Recoverable Hardware Errors PCL Test Printout Busy TimeoutTest Printouts Active Gfid = Gfid CPI=Proportionally Spaced = FSL Test Printout Appendix a Quick Reference Guide to FSL Functions FSL N/SLPI LPI FSL N/SEbcdic =PCL Y10=FSL Are wrapped Y12Y13 Y19 Y22FF after Y26,n1% = No FF Y35 Y41 EABY39 IRQ Y47ESC EEPROM/RAMEeprom Y52Y53 Y54Y55 Y56HEX Y71Y74 PCL mode FSL modeAscii HEX N2dataY79 APLName Syntax Parameters Deviations Y91 Y92Y93 Y94APO Y96Y98 Y112 Y110Y111 Y113 Y114Y115 Y118Re. T2 RAMData Example Cable connections to HP LaserJet Appendix B Using Serial OUTUse of Xerox FS 3270 serial port Appendix C Selected Xerox Products