Xerox 96/4635/180 IPS manual Fuser Lubricant

Page 27

FUSER LUBRICANT

5.Locate the fuser agent reservoir, pull it out until it stops, and remove the reservoir cap by turning it counterclockwise.

6.Remove the cap from a new bottle of fuser agent and carefully pour the fuser agent into the reservoir, until the level reaches the MAX line.

XEROX DOCUPRINT 96/4635/180 IPS GUIDE TO PERFORMING ROUTINE MAINTENANCE

3-3

Image 27
Contents Version 7.1 August 2000 721P88160 Page Ozone information Laser safetyOperation safety Table of contents Index Maintenance and support servicesContents IntroductionAbout this guide Conventions DocuPrint IPS Interactive Customer Documentation CD Related publicationsPage Checking feeder trays Feeder traysGuidelines for loading paper Loading feeder traysProcessor feeder trays trays 1 Loading trays 1Feeder Trays Feeder Trays Feeder Trays Loading trays 3, 4, 5, Feeder Trays Feeder Trays Page Output trays and bins Checking and unloading sample traysChecking and unloading purge trays Unloading a stacker bin To unload a stacker bin Checking and unloading high-capacity stacker HCS binsOutput Trays and Bins Page Fuser lubricant Fuser Lubricant Fuser Lubricant Fuser Lubricant Adding dry ink Adding DRY INK Adding DRY INK Page Replacing the dry ink waste container Replacing the DRY INK Waste Container Replacing the DRY INK Waste Container Page Cleaning the sensors and the reflective surfaces CleaningCleaning the Q850 sensor Cleaning the Q1011 sensor and mirror Sensor Q1107 Cleaning additional sensorsQ1106 and Q1166 Sensor Q1164 Cleaning the 4mm cartridge tape drive Page Xerox Customer Services Support Center Maintenance and support servicesXerox Documentation and Software Services Xerox Font CenterOperator Training Reporting billing meters Xerox Customer EducationBilling Information window Numerics IndexIndex