Xerox D63-069-00 IdaPSS XES Exit Installation and Modification, Install the product tape files

Page 26

idaPSS XES Exit Installation and Modification

This section describes the procedure required to install the idaPSS Exit component sup- plied with this product. The supplied XES Exit software can be installed together with ex- isting program Exits, and does not alter their functionality. The XES input datastream can be printed on the same output devices presently driven by idaPSS (for AFP data). The supplied XES exit software requires installation of User Exit's 1 and 8.

Note: Please ensure that the idaPSS subsystem has previously been successfully in- stalled prior to installing the idaPSS XES conversion Exit.

The following steps are required to install the idaXFC exit for idaPSS:

1.Install the product tape files

2.Install the supplied fonts and codepages

3.Modify the PSS Exit 1 invocation source (optional)

4.Perform XES transform modifications

5.Relink idaPSS program module

6.Implement idaPSS Proclib updates

7.Implement idaPSS Profile updates

8.Implement JCL modifications for XES selection

Install the product tape files

Installation of the product tape is described in "Load the datasets supplied on the product tape" on page 17. The product libraries created do not conflict or modify the current idaPSS installation libraries.

Install the supplied Fonts and Codepages

A minimal of sample AFP fonts in the CG Courier typeface are provided on the installation tape in 300 pel.

These fonts have been provided as samples only, to allow for installation validation, and can be used in conjunction with AFP generator programs, and for printing with idaXFC and IBM AFP printers.

If required, these fonts (and associated code pages) can be installed in an existing 300 pel font libraries.

Modify the PSS Exit 1 invocation source (optional)

Selection of the XES to AFP exit is performed using a modification to Exit 1 that selects XES output based on the value of the JCL OUTPUT DD statement PRMODE option (i.e. PRMODE=XES). If your installation plans on using another PRMODE value to identify the print datastream type, modify the CHANEXIT source appropriately. If you wish to use an- other JCL option to indicate that XES to AFP conversion is required, other you may select

idaPSS XES Exit Installation and Modification 29

Image 26
Contents Ida Xerox File Conversion Installation Guide Ibmmail DK9DXKDXIi ida XFC Product Guide PrefaceCopyright i-data international a-s Preface Revisions with this EditionOrganization of this Publication Table of Contents IdaXFC batch Software Installation and Modification Table of ContentsList of Illustrations Vi ida XFC Product GuideList of Tables List of TablesIda XFC Product Highlights Ida XFC Product HighlightsYear 2000 Support Ida XFC Installation Guide IdaPSS XES Conversion Exit Requirements System RequirementsFunctional Subsystem Spool Converter Requirements System RequirementsPrinter Prerequisites XES to AFP Batch Invocation PrerequisitesPrint Resource Requirements IdaPSS XES Exit Installation Checklist Batch Installation Checklist Load the datasets supplied on the product tape General Installation ProcedureGeneral Installation Procedure Data set name Data set type Organization DescriptionCreate an APF authorized Library or use an existing authlib Ida XFC Spool File Converter Installation ProcedureInstall the supplied fonts and codepages Generate the idaXFC program load moduleAuthorize the Idaxfc program module JES2 InstallationAuthorize the Idaxfc Proc Create/Modify Idaxfc Program Security RulesFssdef FSSNAME=IDAXFC,PROC=IDAXFC,HASPFSSM=HASPFSSM JES3 Installation CA-Spool CustomizationReinitialize The System Sample Idaxfc ProcedureInstall idaXFC Proclib Member Idaxfc Control Profile Description Profile Keyword SyntaxFssname DefaultGeneral idaXFC control profile statements PrinterFONTLIB= IdaPSS Profile Printer Subparameter KeywordsPRTID= LOGDD=A4 Letter A3 Legal Executive Monarch COM10 OVLYLIB=PAPER= PRMODE=JES Output Configuration Parameters Ida XFC Profile Defaults Ida XFC Printer DefaultsIdaPSS XES Exit Installation and Modification IdaPSS XES Exit Installation and ModificationInstall the product tape files Modify the PSS Exit 1 invocation source optionalRelink idaPSS program module Implement idaPSS Proclib updatesPerform XES transform modifications Implement idaPSS Profile updates Implement JCL modifications for XES selectionGeneration of the Load Library IdaXFC batch Software Installation and ModificationIdaXFC batch Installation Procedure Customize the XES TranslationIdaXFC batch Installation Verification Procedure IdaXFC batch Software Installation and ModificationIdaXFC Spool File Converter Operator Commands Stop Start Force DumpIdaXFC Spool File Converter Operator Commands DisplayXES Transform modifications Modification of XES to AFP Font selectionXES Transform modifications Modifications to the Lead-in and Lead-out stringsModification of Page Length and Margins Modifying the Sixel Decoding Table Modifying the Default User Defined KeyModifying the XES Forms Data Definition Reference Changing the Character Mapping and LanguageAppendix A. idaXFC Messages and Codes Appendix A. idaXFC Messages and Codes A-1XES001W IDA XFC is not APF Authorized XES004I NEW Keyword Following COMMA, Comma IgnoredXES011I IDA XFC Product is not Licensed for this Cpuid nnnn XES013I More than ONE Printer Defined in Test ModeXES010I SMF Record Type is TOO Large XES012I no KEY Supplied in IDA XFC ProfileXES014I IDA XFC Running in Test Mode XES015I no Printers DefinedXES021I YOU have Reached MAX Number of Papers XES030I YOU have Reached MAX Number of Printers XES054W no Fsid in CIB XES051I Identify RC =XES053W Wrong Invocation of IDA XFC XES067I Modify Command Completed XES064I TOO Many MODIFIED, Remainder SkippedXES070I no Printer Specified in ADD Command XES071I IDA XFC not Licensed for More PrintersXES077I Idaxfc is Running Test Mode with 2 Printers XES099W More than 100 PSS Started XES087W FSS DISCONNECT, RC = rcXES088I IDA XFC Shutdown Completed XES092I Paper type not Defined for printer A4 UsedXES102I Sync Order Received XES100I command Unknown Afpds Command in MainXES101W Invalid Order Received in FSA XES120I SMF Record Write EnteredXES122I SMF Record Write Terminated XES217I Note Called XES219I Point CalledXES233W Getrec FAILED, FLAGS1= XES231W Getrec FAILED, RC=XES232I GETREC, FLAGS1= XES235I IDXFLAG1 =XES500W FSA Connect Rejected on printer, RC =rc XES501W Internal Error DEQ Pending for printerXES250I Logmsg for user JOBID= number Jobname name XES509I Sync Order Received XES507W Invalid Order Received in FSAXES508I SET Order Received XES511I Intervention Order ReceivedXES513I Start Device Called XES512I ProcXES512I DSN XES514I Stop Device Called XES515I Stop FSA CalledXES520I Valid Checkpoint Returned XES517W Getds REJECTED,RC =XES518I Getds , GDSFLGS1 = XES522I Jesnews Dataset ActiveXES525I jobname Requeued no CHK on printer XES523I Gdsflag =XES524I ffff Active on Printer prtid for userid XES526I jobname Requeued on printerXES533I Notify User Entered XES537I Notify User Terminated XES541W Insufficient Region for JOBXES703I Begin Merge page Entered XES711I Start Line Terminated XES705I Start Graphic EnteredXES710I Start Line Entered XES712I Print Line EnteredXES718I Begin page Entered XES716I END page EnteredXES717I END page Terminated XES719I Begin page TerminatedXES729I Unpacked XES Input Record XES724I Insufficient Region for JOBXES726I Wrong Freemain AT Addr location Called by name XES730I hexadecimal dataXES750I MCF Entered Font = font codepage AS nnn XES753I command Unknown Afpds Command in Font fffffXES754I command Unknown Afpds Command in Code XES751I Invalid Font Control Found in Font fontXES759I Orientation xx not Found in Font ffffffff XES780I CMD=command LENGTH= lllllXES758I MCF Terminated RC= rc XES783I member ddname Opened for ReadXES900I hexadecimal data XES787I member ddname ClosedXES791W dataset member Invalid Record Format Appendix A. idaXFC Messages and Codes A-29XES992I User Exit 2 Entered XES992I User Exit 2 Terminated XES990I User Exit 8 Entered XES990I User Exit 8 TerminatedXES991I User Exit 1 Entered XES991I User Exit 1 Terminated XES998W General Registers R0..R15XES Datastream Appendix B. Data Stream DescriptionInput Datastream Description Appendix B. Data Stream Description B-1Ida XFC Installation Guide XES Datastream Limitations Appendix B. Data Stream Description B-3Glossary Glossary C-1Ida XFC Installation Guide Index Index C-3Node