Xerox D63-069-00 manual XES122I SMF Record Write Terminated

Page 48

XES122I SMF RECORD WRITE TERMINATED

Description

Trace message.

Severity

TRACE message.

Action

none.

XES131I CHECK POINT WRITTEN FOR PAGE nnnn

Description

Trace information message indicating checkpoint activity.

Notes

Information-only message.

XES200W SHORT RECORD FOUND. LENGTH = llllll

Description

An error was encountered processing AFPDS data. An AFPDS com-

 

mand was processed that was less than 9 bytes.

Severity

The output job producing the error is held and processing continues.

Action

Validate that the print output containing AFPDS (X'5A') records has

 

not been corrupted, and that records are minimum 9 bytes in length

 

(X'5A' plus 8 bytes).

XES201I CC =

 

Description

Structured field command indicator.

Notes

Information-only message identifying the structured field being proc-

 

essed.

XES202I CMD=command LENGTH= lllll

Description

Structured field command indicator.

Notes

Information-only message identifying the structured field being proc-

 

essed.

XES210W Dataset member MEMBER NOT FOUND

Description

An expected data member could not be located.

Severity

The output job producing the error is held and processing continues.

Action

Validate that all input data and resources have been supplied.

XES213W dataset member INVALID RECORD FORMAT

Description

The named dataset member contained an invalid record format.

Severity

The output job producing the error is held and processing continues.

Action

Correct the invalid input member. Ensure that the member attributes

 

(RECFM) are set correctly. Allowable record formats are: V or VB

 

with optional Machine or ANSI control characters.

Appendix A. idaXFC Messages and Codes A-13

Image 48
Contents Ida Xerox File Conversion Installation Guide Ibmmail DK9DXKDXPreface Copyright i-data international a-sIi ida XFC Product Guide Revisions with this Edition Organization of this PublicationPreface Table of Contents IdaXFC batch Software Installation and Modification Table of ContentsList of Illustrations Vi ida XFC Product GuideList of Tables List of TablesIda XFC Product Highlights Year 2000 SupportIda XFC Product Highlights Ida XFC Installation Guide System Requirements Functional Subsystem Spool Converter RequirementsIdaPSS XES Conversion Exit Requirements System RequirementsXES to AFP Batch Invocation Prerequisites Print Resource RequirementsPrinter Prerequisites IdaPSS XES Exit Installation Checklist Batch Installation Checklist General Installation Procedure General Installation ProcedureLoad the datasets supplied on the product tape Data set name Data set type Organization DescriptionIda XFC Spool File Converter Installation Procedure Install the supplied fonts and codepagesCreate an APF authorized Library or use an existing authlib Generate the idaXFC program load moduleJES2 Installation Authorize the Idaxfc ProcAuthorize the Idaxfc program module Create/Modify Idaxfc Program Security RulesFssdef FSSNAME=IDAXFC,PROC=IDAXFC,HASPFSSM=HASPFSSM JES3 Installation CA-Spool CustomizationSample Idaxfc Procedure Install idaXFC Proclib MemberReinitialize The System Idaxfc Control Profile Description Profile Keyword SyntaxDefault General idaXFC control profile statementsFssname PrinterIdaPSS Profile Printer Subparameter Keywords PRTID=FONTLIB= LOGDD=OVLYLIB= PAPER=A4 Letter A3 Legal Executive Monarch COM10 PRMODE=JES Output Configuration Parameters Ida XFC Profile Defaults Ida XFC Printer DefaultsIdaPSS XES Exit Installation and Modification Install the product tape filesIdaPSS XES Exit Installation and Modification Modify the PSS Exit 1 invocation source optionalImplement idaPSS Proclib updates Perform XES transform modificationsRelink idaPSS program module Implement idaPSS Profile updates Implement JCL modifications for XES selectionIdaXFC batch Software Installation and Modification IdaXFC batch Installation ProcedureGeneration of the Load Library Customize the XES TranslationIdaXFC batch Installation Verification Procedure IdaXFC batch Software Installation and ModificationIdaXFC Spool File Converter Operator Commands Stop Start Force DumpIdaXFC Spool File Converter Operator Commands DisplayXES Transform modifications Modification of XES to AFP Font selectionModifications to the Lead-in and Lead-out strings Modification of Page Length and MarginsXES Transform modifications Modifying the Default User Defined Key Modifying the XES Forms Data Definition ReferenceModifying the Sixel Decoding Table Changing the Character Mapping and LanguageAppendix A. idaXFC Messages and Codes Appendix A. idaXFC Messages and Codes A-1XES001W IDA XFC is not APF Authorized XES004I NEW Keyword Following COMMA, Comma IgnoredXES013I More than ONE Printer Defined in Test Mode XES010I SMF Record Type is TOO LargeXES011I IDA XFC Product is not Licensed for this Cpuid nnnn XES012I no KEY Supplied in IDA XFC ProfileXES014I IDA XFC Running in Test Mode XES015I no Printers DefinedXES021I YOU have Reached MAX Number of Papers XES030I YOU have Reached MAX Number of Printers XES051I Identify RC = XES053W Wrong Invocation of IDA XFCXES054W no Fsid in CIB XES067I Modify Command Completed XES064I TOO Many MODIFIED, Remainder SkippedXES070I no Printer Specified in ADD Command XES071I IDA XFC not Licensed for More PrintersXES077I Idaxfc is Running Test Mode with 2 Printers XES087W FSS DISCONNECT, RC = rc XES088I IDA XFC Shutdown CompletedXES099W More than 100 PSS Started XES092I Paper type not Defined for printer A4 UsedXES100I command Unknown Afpds Command in Main XES101W Invalid Order Received in FSAXES102I Sync Order Received XES120I SMF Record Write EnteredXES122I SMF Record Write Terminated XES217I Note Called XES219I Point CalledXES231W Getrec FAILED, RC= XES232I GETREC, FLAGS1=XES233W Getrec FAILED, FLAGS1= XES235I IDXFLAG1 =XES501W Internal Error DEQ Pending for printer XES250I Logmsg for user JOBID= number Jobname nameXES500W FSA Connect Rejected on printer, RC =rc XES507W Invalid Order Received in FSA XES508I SET Order ReceivedXES509I Sync Order Received XES511I Intervention Order ReceivedXES512I Proc XES512I DSNXES513I Start Device Called XES514I Stop Device Called XES515I Stop FSA CalledXES517W Getds REJECTED,RC = XES518I Getds , GDSFLGS1 =XES520I Valid Checkpoint Returned XES522I Jesnews Dataset ActiveXES523I Gdsflag = XES524I ffff Active on Printer prtid for useridXES525I jobname Requeued no CHK on printer XES526I jobname Requeued on printerXES533I Notify User Entered XES537I Notify User Terminated XES541W Insufficient Region for JOBXES703I Begin Merge page Entered XES705I Start Graphic Entered XES710I Start Line EnteredXES711I Start Line Terminated XES712I Print Line EnteredXES716I END page Entered XES717I END page TerminatedXES718I Begin page Entered XES719I Begin page TerminatedXES724I Insufficient Region for JOB XES726I Wrong Freemain AT Addr location Called by nameXES729I Unpacked XES Input Record XES730I hexadecimal dataXES753I command Unknown Afpds Command in Font fffff XES754I command Unknown Afpds Command in CodeXES750I MCF Entered Font = font codepage AS nnn XES751I Invalid Font Control Found in Font fontXES780I CMD=command LENGTH= lllll XES758I MCF Terminated RC= rcXES759I Orientation xx not Found in Font ffffffff XES783I member ddname Opened for ReadXES787I member ddname Closed XES791W dataset member Invalid Record FormatXES900I hexadecimal data Appendix A. idaXFC Messages and Codes A-29XES990I User Exit 8 Entered XES990I User Exit 8 Terminated XES991I User Exit 1 Entered XES991I User Exit 1 TerminatedXES992I User Exit 2 Entered XES992I User Exit 2 Terminated XES998W General Registers R0..R15Appendix B. Data Stream Description Input Datastream DescriptionXES Datastream Appendix B. Data Stream Description B-1Ida XFC Installation Guide XES Datastream Limitations Appendix B. Data Stream Description B-3Glossary Glossary C-1Ida XFC Installation Guide Index Index C-3Node