Xantrex Technology 600HD manual Charging

Page 49

Troubleshooting Reference

Table 5-1Troubleshooting reference

Problem

Possible Cause

Solution

 

 

 

Measured AC

Use of an

The modified sine wave (MSW)

output voltage

average-reading AC

output of the XPower Powerpack

is too low.

voltmeter to read

requires a true RMS reading meter,

 

output voltage.

such as the Fluke 87 series, for

 

 

accurate measurement.

 

Battery is almost fully

Press display function button to

 

discharged.

verify battery status and recharge the

 

 

XPower Powerpack as necessary.

 

 

“Battery Charge %” reading on the

 

 

digital display is only accurate when

 

 

the XPower Powerpack has been

 

 

disconnected from all appliances and

 

 

all charging sources for 15 minutes.

 

 

 

Charging

No AC power at the

Ensure power is available at the AC

Status light is

AC wall outlet.

wall outlet.

OFF when AC

 

 

charger is

AC charger is faulty.

Replace the AC charger.

connected

 

 

 

 

 

Green

Battery charge (%)

Unplug the charging sources and any

Charging

reading on digital

appliances and let the XPower

Status light is

display is only

Powerpack rest for 15 minutes to

flashing

accurate when the

obtain an accurate reading.

(indicating

XPower Powerpack

 

recharging)

has been disconnected

 

and battery

from all appliances

 

charge (%)

and all charging

 

does not turn

sources for 15

 

on.

minutes.

 

 

 

 

36

975-0213-01-01

Image 49
Contents XPower Powerpack 600HD Owner’s Guide XPower Powerpack 600HDDate and Revision Conventions Used PurposeRelated Information Important Safety Instructions Safety Safety Precautions When Working With Batteries Precautions for Using Rechargeable Appliances Viii Contents Troubleshooting MaintenanceSpecifications Introduction About the XPower Powerpack 600HDComprehensive Protection Automatic overloadJump-Start Cables Safety Feature Low Battery ProtectionMaterials List FeaturesFront Panel Features XPower Powerpack 600HD FeaturesFeature Description Front Panel DetailControl Panel Operation Required How to Condition Required ActionCharging Status Radio and Clock Features AM/FM Radio with Digital Alarm ClockRadio and Clock Operation Left Side View DC Power Socket canDetachable heavy-duty jump-start cables AccessoriesOperating Conditions and Guidelines OperationChoosing a Location Dry Cool Ventilated Safe Protected from battery gasesRecharging with the AC Charger Using XPower Powerpack 600HD for the First TimeTo recharge with the AC Charger Operating AC Appliances Using the LightUnderstanding AC Appliances Run Time on Typical AC Appliances AC-powered Products Watts a Run time hours bTrouble Appliances To operate an AC appliance Operating an AC ApplianceDC Appliance Watts a Run Time Hours b Operating 12 V DC AppliancesTo operate a 12 V DC appliance To jump-start a vehicle or boat engine Jump-Starting a Vehicle’s EngineJump-Starting a Vehicle’s Engine Connecting to an External Battery Using the RadioPower Draw Listening to the AM BandConnecting to an External Battery Connecting to an External Battery Battery Maintenance MaintenanceFunction button Recharging the XPower Powerpack 600HD BatteryRecharging with the AC Charger Recharging with the DC Charging Cable Recharging the XPower Powerpack 600HD Battery Recharging From a Solar Panel Recharging with a Generator’s Regulated 12 V DC Outlet1Typical DC Coaxial Connector Connection To wire the coaxial DC connectorReplacing the External Fuse Replacing the Incandescent LightTo replace the light bulb To replace the external fuseCommon Problems TroubleshootingBuzz in Audio Equipment Television InterferenceProblem Possible Cause Solution Troubleshooting ReferenceGreen Charging Status light is Charging Green Voltage at the AC Use AC wall outlet that supplies Page Electrical Specifications SpecificationsDC Section Internal Battery Charging Controller System AC Power SectionAccessories Physical SpecificationsRadio Page Warranty Warranty and Return InformationWarranty and Return Product DisclaimerExclusions Return Procedure Return Material Authorization PolicyOut of Warranty Service Serial Number Purchased From Purchase Date Information About Your System975-0213-01-01 REV. a