EMC

This instrument has been designed to meet the requirements of the EMC Directive 89/336/EEC. Compliance was demonstrated by meeting the test limits of the following standards:

Emissions

EN61326 (1998) EMC product standard for Electrical Equipment for Measurement, Control and Laboratory Use. Test limits used were:

a)Radiated: Class B

b)Conducted: Class B

Immunity

EN61326 (1998) EMC product standard for Electrical Equipment for Measurement, Control and Laboratory Use.

Test methods, limits and performance achieved were:

a)EN61000-4-2 (1995) Electrostatic Discharge : 4kV air, 4kV contact, Performance A.

b)EN61000-4-3 (1997) Electromagnetic Field, 3V/m, 80% AM at 1kHz, Performance B.

c)EN61000-4-11 (1994) Voltage Interrupt, 1 cycle, 100%, Performance B.

d)EN61000-4-4 (1995) Fast Transient, 1kV peak (AC line), 0.5kV peak (DC Outputs), Performance B.

e)EN61000-4-5 (1995) Surge, 0.5kV (line to line), 1kV (line to ground), Performance B.

f)EN61000-4-6 (1996) Conducted RF, 3V, 80% AM at 1kHz (AC line only; DC Output connections <3m not tested), Performance B.

According to EN61326 the definitions of performance criteria are:

Performance criterion A: ‘During test normal performance within the specification limits.’

Performance criterion B: ‘During test, temporary degradation, or loss of function or performance which is self-recovering’.

Performance criterion C: ‘During test, temporary degradation, or loss of function or performance which requires operator intervention or system reset occurs.’

Where Performance B is stated it is because DC Output regulation may deviate beyond Specification limits under the test conditions. However, the possible deviations are still small and unlikely to be a problem in practice.

Note that if operation in a high RF field is unavoidable it is good practice to connect the PSU to the target system using screened leads which have been passed (together) through an absorbing ferrite sleeve fitted close to the PSU terminals.

Cautions

To ensure continued compliance with the EMC directive observe the following precautions:

a)after opening the case for any reason ensure that all signal and ground connections are remade correctly and that case screws are correctly refitted and tightened.

b)In the event of part replacement becoming necessary, only use components of an identical type, see the Service Manual.

5

Image 6
Contents XPH Series 42V 10A DC Power Supply XPHPart Number Contact InformationTable of Contents IntroductionSpecification OutputSafety Emissions ImmunityMains Operating Voltage InstallationConnections Mains LeadOperation Cleaning MaintenanceOver-temperature Protection Series or Parallel Connection with Other OutputsSécurité Avertissement ! CET Instrument Doit Etre Relie a LA TerreCâble secteur ConnexionsTension d’utilisation secteur AVERTISSEMENT! CET Instrument Doit Etre Relie a LA TerreFonctionnement Fusible Connexion en série ou en parallèle avec d’autres sortiesProtection contre la surchauffe NettoyageSicherheit WARNUNG! Dieses Gerät Muss Geerdet WerdenNetzkabel AnschlüsseNetzbetriebsspannung BelüftungBetrieb VerbraucheranschlußIstwert-Fernerfassung Reihen- und Parallelschaltung mit anderen Ausgängen ÜbertemperaturschutzWartung SicherungReinigung Sicurezza ATTENZIONE! Questo Strumento Deve Essere Collegato a TerraInstallazione CollegamentiFunzionamento Protezione Corrente costanteUscita di corrente istantanea Llacciamento del caricoFusibile ManutenzioneProtezione da temperatura eccessiva PuliziaSeguridad ADVERTENCIA! Este Instrumento Debe Conectarse a TierraInstalación ConexionesOperación Protección Corriente ConstanteSalida Instantánia de Corriente Conexión a la CargaMantenimiento Protección contra SobretemperaturaLimpieza Warranty Information How do you get service?What does this warranty not cover? ProductReturn Material Authorization Policy Xantrex Technology Inc