Advanced menus

The Advanced menus provide additional options for the UPS and are available only if the display interface is configured to use the Advanced menus.

Menu

General Functions

 

 

 

 

 

View detailed UPS information:

 

 

• Operating Mode

• Battery Temp

 

• Efficiency

• Input

 

• Load Power

• Output

Status

• Load VA

• Last Transfer

• Load Amps

• Last UPS Self Test

 

 

• Load Energy

• Outlet Group 1 (if Controlled Outlet is available)

 

• Battery Charge state

• NMC IP Address (if NMC is available)

 

• Estimated Runtime

 

 

• Battery Voltage

 

 

 

 

 

Configure advanced UPS settings:

 

 

• Language

• Battery Install Date

 

• Local Power Quality

• Reset Energy Meter

 

• Menu Type

• Enter Setup Wizard

Configuration

• Audible Alarm

• Firmware Update (standby mode)

• Display (Auto Dim, Auto Off, Always On)

• Reset to Factory Default

 

• Sensitivity

• Config Main Group Outlets

 

• Low Transfer

• Config Group 1 Outlets (if Controlled Outlet is

 

• High Transfer

available)

 

• Low Battery Warning

• Config NMC (if NMC is available)

 

• Auto Self Test

 

 

 

Control

Control the Main and Switched Outlet Group to turn on, turn off, shutdown, or reboot.

 

 

 

 

Perform UPS test and diagnostic functions:

 

Test & Diags

• UPS Self Test

 

• UPS Alarms Test

 

 

 

 

• Calibration Test

 

 

 

Log

View the event and error logs for information about UPS events and faults that have occurred.

 

 

 

 

View UPS information:

 

 

• UPS Model

• NMC Model No.*

 

• UPS Part No.

• NMC Serial No.*

 

• UPS Serial No.

• NMC Hardware Version*

 

• UPS Manufacture Date

• NMC Manufacture Date*

About

• Battery Part No.

• NMC MAC Address*

• Battery Install Date

• SmartSlot FW 1*

 

 

• Replace Battery by

• SmartSlot FW 2*

 

• UPS Firmware 1

• SmartSlot FW 3*

 

• UPS Firmware 2

*If NMC is available

 

• UPS Firmware 3

 

• UPS Firmware 4

 

 

 

 

Smart-UPS 750/1000/1500/2200/3000 VA 100/120/230 Vac / 500 VA 100 Vac Tower

7

Image 9
Contents Smart-UPSUninterruptible Power Supply Page Safety and General Information Important Safety MessagesOverview Product DescriptionEnvironmental SpecificationsFront panel features Rear panel features 500 VA to 1500 VA modelsProduct Overview Rear panel features 2200 VA and 3000 VA models Installation2200 VA 120 Vac 2200/3000 VA 100 Vac 2200/3000 VA 230 Vac 3000 VA 120 VacRear Panel Features OperationConnect Equipment Display Panel Using the display interfaceStandard menus Menu General FunctionsAdvanced menus ControlLog UPS Settings ConfigurationStart up Settings General SettingsLow Transfer Point Using the Main and Controlled Outlet Groups Main Outlet Group and Controlled Outlet GroupOverview Customize the Main and Controlled Outlet Groups Network Management Card SettingsEmergency Power Off Normally open contactsNormally closed contacts UPS does not provide expected backup time TroubleshootingUPS displays a site wiring fault message UPS is emits intermittent beepsTransport the unit ServiceTwo Year Limited Factory Warranty EN 990-3534D 03/2013 APC by Schneider Electric Worldwide Customer Support