Transition Networks SISTF1010-150-LR(T) Connecting power to the Industrial Switch

Page 21

SISTF1010-150-LR(T) Industrial Unmanaged Switch

Transition Networks

Connecting power to the Industrial Switch, continued

Note: The terminal block can accept 12 – 24 AWG wire for power and alarm relay inputs.

Terminal-block To wire the 6-position terminal block for redundant power, do the following: wiring

Note: The 6-position terminal-block plug is constructed (keyed) to mate with the Industrial Switch terminal block. When wiring the plug for power, use the polarity markings next to the terminal block and on top of the plug to ensure proper connection.

Step

Action

1.

Turn the external power source OFF.

2.

Strip the power wires as required.

3.

Insert one stripped power wire into the terminal block plug. Observe polarity.

 

See Figure 9.

4.

Secure the wire using a flathead screwdriver by tightening the contact screw.

 

See Figure 9.

5.

Repeat Steps 3 and 4 until all wires are installed and secured.

Figure 9: 6-Position Terminal-Block (Primary/Redundant Power Wiring)

Continued on next page

24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600

13

Image 21
Contents SISTF1010-150-LRT Installation ManualPage Table of Contents Transition Networks SISTF1010-150-LRT Trademark, copyright, and product classification information III About this product and manualOn next Transition Networks Section SISTF1010-150 Industrial Unmanaged Switch General description SISTF1010-150 Industrial Unmanaged Switch part numbers Package contents Physical description SISTF1010-150-LRT Industrial Switch Front ViewPhysical description Section Installation DIN rail mounting DIN rail mounting Wall mount Wall mountingGrounding the Industrial Switch Connecting power to the Industrial Switch Connecting power to the Industrial Switch Connecting power to the Industrial Switch Barrel Connector Interface Cable Connecting copper cables LNK/ACT Light Emitting Diodes LEDsSection Advanced Features Straight-Through and Crossover Cables Advanced FeaturesSection Cable Specifications Copper RJ-45 cable specifications Section TroubleshootingTroubleshooting problem and corrective action table Section Contact Us, Warranty Compliance Information Contact us Warranty Warranty Cuation Compliance informationSISTF1010-150-LRT Industrial Unmanaged Switch SISTF1010-150-LRT specifications, notices, and warnings Appendix a Technical SpecificationsSISTF1010-150-LRT specifications, notices, and warnings