Transition Networks E-TBT-HB-0804, 33022.B specifications 10BASE-2 Cable Specifications

Page 2

CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.

Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.

Compliance Information

UL Listed

C-UL Listed (Canada)

CISPR/EN55022 Class A

FCC Regulations

This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.

Canadian Regulations

This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.

European Regulations

Warning

This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Copyright Restrictions

10BASE-2 Cable Specifications

The physical characteristics of the 10BASE-2 cable must meet or exceed IEEE 802.3 10BASE-2 specifications.

Cable Characteristics:

Cable type:

Stranded Coaxial RG58 (ThinNet)

Impedance:

50 Ω @ 10 MHz

 

Mutual Capacitance:

24 pF/ft ±20% @ 10

MHz

Maximum Cable Length:

185 meters (610 feet)

Maximum number network connections:

30

 

Minimum distance between connections:

0.5 meters (1.6 feet)

 

Terminate 10BASE-2 cable at one end using a 50 ohm terminator and at the other end using a 50 ohm terminator grounded to earth ground.

10BASE-T Cable and Connector Specifications

The physical characteristics of the 10BASE-T cable must meet or exceed IEEE

802.310BASE-T specifications.

10BASE-T Cable Characteristics:

Category 3 wire or better is required; category 5 wire is recommended. Either shielded twisted pair (STP) or unshielded twisted pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE.

Category 3:

 

Gauge

24 to 22 AWG

Attenuation

28 dB/1000’ @ 10 MHz

Differential Characteristic Impedance

100 Ω ±10% @ 10 MHz

Category 5:

 

Gauge

24 to 22 AWG

Attenuation

20 dB/1000’ @ 10 MHz

Differential Characteristic Impedance

100 Ω ±10% @ 10 MHz

Maximum Cable Length:

100 meters (330 feet)

10BASE-T Connector Characteristics:

The two active pairs in a 10BASE-T network are pins 1 & 2 and pins 3 & 6. Use only dedicated wire pairs (such as blue/white & white/blue, orange/white

&white/orange) for the active pins. 10BASE-T cable for unlike devices (such as hub to terminal device) must be configured as straight through; 10BASE-T cable for like devices (such as hub to hub or terminal device to terminal device) must be configured as crossover.

© 1997 TRANSITION Networks.

All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.

Trademark Notice

Twisted Pair #1

Twisted Pair #2

Straight Through Cable

11

22

33

66

Twisted Pair #1

Twisted Pair #2

Crossover Cable

11

22

33

66

All registered trademarks and trademarks are the property of their respective owners.

Connectors for unlike devices

Connectors for like devices

LANMaster™ T8

8-Port Ethernet™ Repeater Hub

20

Image 2
Contents Lanmaster T8 8-PORT HUB Specifications TBT-HB-0804LANMaster T8 Port Ethernet Repeater Hub 10BASE-2 Cable Specifications10BASE-T Cable and Connector Specifications Ethernet Cable Specifications Table of ContentsLANMaster T8 FeaturesIntroduction Warranty Statement Networking the LANMaster T8Connectors MaintenanceConnectors and Indicators Technical Support ContactMonitoring Status LEDs OperationSite Considerations Unpacking the LANMaster T8 InstallationPowering the LANMaster T8 Part NumberConnecting to Network Using Transceiver Installing Thicknet 10BASE-5 CableConnecting to 10BASE-5 Using AUI Drop Cable To install the LANMaster T8 on table or other flat surfaceSTRAIGHT-THROUGH/CROSSOVER CABLE/CONNECTOR Installing Network CableInstalling Thinnet 10BASE-2 Cable 10BASE-T Requirements10BASE-5 Requirements Installing Twisted-Pair 10BASE-T Cable10BASE-2 Requirements 10-Mb/s Baseband Network Configuration Guidelines

33022.B, E-TBT-HB-0804 specifications

Transition Networks E-TBT-HB-0804,33022.B is a highly specialized network device designed to support the demanding needs of enterprise-grade communications. This high-performance media converter offers a seamless transition between copper-based Ethernet networks and fiber optic networks, making it an ideal solution for businesses looking to enhance their network infrastructure.

One of the main features of the E-TBT-HB-0804,33022.B is its 10/100/1000 Mbps auto-sensing Ethernet ports, which enable users to connect various devices without worrying about compatibility issues. This flexibility ensures that both legacy and modern devices can be integrated into the network, providing a cost-effective solution for organizations seeking to upgrade their systems without a complete overhaul.

The device is built with robust technologies that ensure reliable performance. It supports full-duplex and half-duplex operation modes, allowing for efficient data transmission across the network. Additionally, the E-TBT-HB-0804,33022.B is equipped with advanced Auto-MDI/MDIX capabilities, which eliminate the need for crossover cables and further simplify connections, making setup quicker and more convenient for IT personnel.

In terms of characteristics, the E-TBT-HB-0804,33022.B boasts a compact design that fits easily into any network environment. Its durable construction ensures longevity, while the fanless design contributes to silent operation, making it suitable for noise-sensitive locations. Furthermore, it features LED indicators that provide real-time monitoring of network status and activity, allowing for quick troubleshooting and maintenance.

Another noteworthy aspect of this device is its compatibility with various types of fiber optic cables, including single-mode and multimode fibers. This versatility enables organizations to choose the best cabling solution to meet their specific distance and bandwidth requirements. The E-TBT-HB-0804,33022.B is also designed to support PoE (Power over Ethernet), allowing users to power network devices directly through the Ethernet cable, reducing the number of power adapters needed.

In conclusion, Transition Networks E-TBT-HB-0804,33022.B is an essential tool for businesses seeking to bridge the gap between copper and fiber networks. With its blend of advanced features, reliable technologies, and durable design, it provides a seamless networking experience that can adapt to evolving organizational needs. Whether upgrading an existing network or building a new one, the E-TBT-HB-0804,33022.B is an excellent choice for enhancing connectivity and performance.