IBM Netcool/OMNIbus Probe for Nortel CNM Probe cannot parse Check that the Nortel CNM, Necessary

Page 25

Table 7. Error messages (3 of 4)

Error

Description

Action

 

 

 

Error to parse event

The probe cannot parse the

Check that the Nortel CNM

completely

alarm; this is probably because

server is running correctly.

Failed to parse event

the alarm is not in a format that

 

the probe can understand.

 

completely

 

 

 

Name is null, cannot

 

 

create Element

 

 

NetcoolIRPManager:

 

 

Category Value NOT

 

 

supported: Discarding

 

 

Alarm

 

 

NetcoolIRPManager:

 

 

Error when parsing

 

 

event

 

 

NetcoolIRPManager:

 

 

Failed to send event

 

 

 

 

 

Failed to get timeout

The Timeout property has not

Check the value for the Timeout

property value,

been set.

property; change this value if

defaulting to 0

 

necessary.

 

 

 

Failed to find the

The probe could not get the

Check the value for the

AlarmIRP object

AlarmIRP object using the

AlarmIrpName property;

 

EntryPoint IRP.

change this value if necessary.

 

 

 

Failed to find the

The probe could not get the

Check the value for the

NotificationIRP

NotificationIRP object

NotificationIrpName

object

using the EntryPoint IRP.

property; change this value if

 

 

necessary.

 

 

 

Failed to perform

The probe could not

Check the value for the Resynch

resynch

resynchronize the alarms with

property; change this value if

 

device.

necessary.

 

 

 

Failed to narrow

The probe has failed to get the

Check the value for the

Security IRP

EntryPointIRP object.

SecurityIrpFtpCommand

interface

 

property; change this value if

SECURITY: Failed to

 

necessary.

 

 

get IRP object :

 

 

SECURITY: Unknown

 

 

exception occured

 

 

 

 

 

NetcoolIRPManager:

This message is generated by

This message is intended for use

Stack Trace to stder:

the Netcool IRP Manager.

when debugging.

 

 

 

NetcoolIRPManager:

The probe has failed to get the

Check the value for the

Failed to retrieve

EntryPointIRP object.

SecurityIrpFtpCommand

EntryPointIRP object

 

property; change this value if

from security

 

necessary.

interface:

 

 

 

 

 

Probe for Nortel CNM 19

Image 25
Contents Reference Guide Netcool/OMNIbus Probe for Nortel CNMPage Contents Iv Netcool/OMNIbus Probe for Nortel CNM Reference Guide Document Publication Comments Version Date Document controlVi Netcool/OMNIbus Probe for Nortel CNM Reference Guide Probe for Nortel CNM Summary SummaryInstallation requirements Basic configurationSupported platforms Updating the rules fileData acquisition Connecting to the Corba interfaceStatus checking TimeoutRetrieving objects Running multiple probesElement Token Filtering notifications and alarmsCommand Description Command line interfaceNotifications and alarms on Same format as the AlarmFilterAllows you to unacknowledge an alarm Allows you to clear an alarm in the 3GPP2 interfacePeer-to-Peer failover functionality Example property file settings for peer-to-peer failoverInternationalization support Example multi-byte character set configuration on SolarisProperty name Command line option Description Properties and command line optionsInformation on CLI, see Command line Using the Command Line Interface CLIDefault is 32.363 Default is 32.303Using the ncogcrypt utility. For Password required with the UsernameHe default is false TimeoutSession remains open to connections. This Time in minutes that the Notificiation IRPIs used by the 3GPP server Forever openElement name Element description ElementsCause of the alarm Dynamically and its content is dependent on the IRPName of the user who uses the service Name of the service providerError Description Action Error messagesCorba interface Documentation There is a problem with Refer to your CorbaProbe cannot connect to Check that the Nortel CNM Server Server is running correctlyAlarm is not in a format that Probe can understand Alarm this is probably because Server is running correctlyTimeout property has not Check the value for the Timeout AlarmIRP object usingWhile connecting to Probe found a problem Check the values set forThere was a problem with Check that the Nortel CNM Probe has failed to take Check the value forProbeWatch message Description Triggers/causes ProbeWatch messagesPassword given in the properties Probe could not login to Incorrect usernameListen for commands Probe has failed to get AlarmirpFile propertyUnexpected fatal error Probe could not get new Probe failed to get the alarmCommands on the specified Receive commands Probe encountered an Contact the IBM supportNetcool/OMNIbus Probe for Nortel CNM Reference Guide Appendix A. Notices JBFA/SOM1 AIX AIX 5L TrademarksNetcool/OMNIbus Probe for Nortel CNM Reference Guide