IBM Netcool/OMNIbus Probe for Nortel CNM manual Properties and command line options

Page 17

Properties and command line options

Table 5 describes the properties and command line options specific to this probe. For information about generic probe properties and command line options, see the IBM Tivoli Netcool/OMNIbus Probe and Gateway Guide, (SC23-6387).

Table 5. Properties and command line options (1 of 4)

Property name

Command line option

Description

 

 

 

AckSystemId string

-acksystemid

Processing system on which the IRP

 

string

Manager runs. This is used by the

 

 

acknowledge_alarm CLI function.

 

 

The default is "".

 

 

 

AckUserId string

-ackuserid string

Name of the user acknowledging the

 

 

alarm. This is used by the acknowledge_

 

 

alarm CLI function.

 

 

The default is "".

 

 

 

Agentheartbeat

-agentheartbeat

Frequency (in seconds) with which the

integer

integer

probe checks the status of the IRP agent.

 

 

The default is 60.

 

 

 

AlarmFilter string

-alarmfilter

Filter the alarm IRP uses to limit the alarms

 

string

sent to the probe.

 

 

The default is "".

 

 

 

AlarmIrpName

-alarmirpname

Name of the Alarm IRP Agent.

string

string

The default is 32.111-3 V6.5.

 

 

 

 

 

ClearSystemId

-clearsystemid

Name of the IRP Manager that supports the

string

string

user who clears the alarms using the CLI.

 

 

It can be used to identify the system, such

 

 

as system 6, or it can contain no

 

 

information such as "".

 

 

The default is "".

 

 

For more information on CLI, see

 

 

"Command line interface" on page 7.

 

 

 

ClearUserId string

-clearuserid

Name of the user clearing the alarms used

 

string

by the CLI function of the probe.

 

 

The identity can be a human operator such

 

 

as "John Smith", or a group such as

 

 

"Team Six", or it can contain no

 

 

information such as "".

 

 

The default is "".

 

 

For more information on CLI, see

 

 

"Command line interface" on page 7.

 

 

 

Probe for Nortel CNM 11

Image 17
Contents Reference Guide Netcool/OMNIbus Probe for Nortel CNMPage Contents Iv Netcool/OMNIbus Probe for Nortel CNM Reference Guide Document Publication Comments Version Date Document controlVi Netcool/OMNIbus Probe for Nortel CNM Reference Guide Probe for Nortel CNM Summary SummaryInstallation requirements Basic configurationSupported platforms Updating the rules fileData acquisition Connecting to the Corba interfaceStatus checking TimeoutRetrieving objects Running multiple probesElement Token Filtering notifications and alarmsCommand Description Command line interfaceNotifications and alarms on Same format as the AlarmFilterAllows you to unacknowledge an alarm Allows you to clear an alarm in the 3GPP2 interfacePeer-to-Peer failover functionality Example property file settings for peer-to-peer failoverInternationalization support Example multi-byte character set configuration on SolarisProperty name Command line option Description Properties and command line optionsInformation on CLI, see Command line Using the Command Line Interface CLIDefault is 32.363 Default is 32.303Using the ncogcrypt utility. For Password required with the UsernameHe default is false TimeoutSession remains open to connections. This Time in minutes that the Notificiation IRPIs used by the 3GPP server Forever openElement name Element description ElementsCause of the alarm Dynamically and its content is dependent on the IRPName of the user who uses the service Name of the service providerError Description Action Error messagesCorba interface Documentation There is a problem with Refer to your CorbaProbe cannot connect to Check that the Nortel CNM Server Server is running correctlyAlarm is not in a format that Probe can understand Alarm this is probably because Server is running correctlyTimeout property has not Check the value for the Timeout AlarmIRP object usingWhile connecting to Probe found a problem Check the values set forThere was a problem with Check that the Nortel CNM Probe has failed to take Check the value forProbeWatch message Description Triggers/causes ProbeWatch messagesPassword given in the properties Probe could not login to Incorrect usernameListen for commands Probe has failed to get AlarmirpFile propertyUnexpected fatal error Probe could not get new Probe failed to get the alarmCommands on the specified Receive commands Probe encountered an Contact the IBM supportNetcool/OMNIbus Probe for Nortel CNM Reference Guide Appendix A. Notices JBFA/SOM1 AIX AIX 5L TrademarksNetcool/OMNIbus Probe for Nortel CNM Reference Guide