IBM 32x, W2H, 31x manual Carriage return 0D CR, Test 0F SI, Display position 10 DLE

Page 38

Input/output device commands

11-9-2005

line is cleared, and the cursor position is unchanged. This command always stops the scrolling alphanumeric message.

Carriage return (0D) <CR>

0D

Purpose:

Causes the cursor to move to the leftmost position of the current line. This command stops the scrolling alphanumeric message if the cursor position is on the top line when this command is sent.

Test (0F) <SI>

0F

Purpose:

Causes the first 40 characters in the currently selected character set to be displayed once. At the end of the test, a test pattern is written that turns all pixels ON. At the end of the test, the display is cleared and is reset to the power-on state as described at “Reset (1F) <US>” on page A-7.

Display position (10) <DLE>

10nn

Purpose:

Changes the cursor position. The byte that follows the command byte indicates the character position where the next data-string write operation is to start. Any values greater than X'27' are ignored and the cursor position remains unchanged. This command stops the scrolling alphanumeric message if the cursor position is on the top line when this command is sent.

X'00'

Top left

X'13'

Top right

X'14'

Bottom left

X'27'

Bottom right

Normal-display control mode (11) <DC1>

11

Purpose:

Sets normal display-control mode (DC1) and permits data to be written to either line. After a character is written, the cursor moves one position to the right. When the display position is at the last position of the top line, the cursor moves to the first position of the bottom line. When the display position is at the last position of the bottom line, the cursor moves to the first position of the top line. The display remains in DC1 mode until a DC2 mode command is issued, a reset command is issued, or power is removed from the display.

A-6SurePOS Installation and Service

Image 38
Contents SurePOS Page SurePOS Second Edition March Contents Iv SurePOS Installation and Service Figures Vi SurePOS Installation and Service Who should read this manual Driver and Service Diskette InformationAbout this guide Related publicationsEnd of life disposal AccessibilityUninterruptible power supply option About this guide Tell us what you think Summary of changes Xii SurePOS Installation and Service Introduction Physical dimensions Product introductionFront view and LEDs Environmental considerationsRear connectors Rear connectors 4810 31x modelsPower Rear connectors 32x models 4shows the connections available on the 4810/4910 modelsPower. The voltage switch allows you to select 8SurePOS Installation and Service Disassembling the 4810/4910 SurePOS View of componentsBracket assembly and hard drive On page 1-4to locate the voltage selection switch 4SurePOS Installation and Service Problem determination Preliminary checklistProblem determination Parts catalog Assembly 1 Field-replaceable units Assembly 4SurePOS Installation and Service Emulation mode select 00 Null Appendix A. Input/output device commandsCharacter display VFD commands Character set select 02 STXLogic Controls Emulation Mode User character definition 03 EXTIBM Mode Bit Byte #Brightness control 04 EOT Alphanumeric message scroll 05 ENGBackspace 08 BS Normal Display Control Mode DC1Vertical Scroll Display Control Mode DC2 Horizontal tab 09 HTTest 0F SI Normal-display control mode 11 DC1Carriage return 0D CR Display position 10 DLECursor on 13 DC3 Vertical-scroll display control mode 12 DC2Reset 1F US Cursor off 14 DC4Null VFD Commands Line feed APA commandsBackspace without deleting Clear display Carriage returnTest Display positionDimming Cursor modeScreen mode Display mode set Horizontal scrollJapanese User-definable font setFont size At the all language X20--XFF English Horizontal scroll on all lines Graphic display modeDouble-size letter in horizontal Format of the Horizontal Scroll Start command is as follows Null Commands Font selectionAppendix B. Notices European Community CE mark of conformity statement Industry Canada class a emission compliance statementAvis de conformité aux normes d’Industrie Canada GermanyAppendix B. Notices B-3 Korean Communications Statement ESD Damage Prevention Handling Removed CardsTrademarks Appendix C. Safety information GevaarPerigo FareVorsicht VigyázatPericolo PeligroVarning-livsfara IBM GA27-4004 IBM GA27-4004 8SurePOS Installation and Service Index Numerics APA A-9Power Cooling Light off Power supply Readers’ Comments We’d Like to Hear from You How satisfied are you that the information in this book isBusiness Reply Mail Page Part Number 03R5994