Cisco Systems WSC2960X48TDL Monitoring EEE, Specifies the interface to be configured, and enter

Page 103

Configuring EEE

Monitoring EEE

 

Command or Action

Purpose

Step 2

interface interface-id

Specifies the interface to be configured, and enter

 

 

interface configuration mode.

 

Example:

 

 

Switch(config)# interface gigabitethernet1/0/1

 

Step 3

power efficient-ethernet auto

Example:

Switch(config-if)#power efficient-ethernet auto

Enables EEE on the specified interface. When EEE is enabled, the device advertises and autonegotiates EEE to its link partner.

Step 4

no power efficient-ethernet auto

Disables EEE on the specified interface.

Example:

Switch(config-if)# no power efficient-ethernet auto

Step 5

end

Returns to privileged EXEC mode.

Example:

Switch(config-if)# end

Step 6

copy running-config startup-config

(Optional) Saves your entries in the configuration file.

Example:

Switch# copy running-config startup-config

Monitoring EEE

Table 12: Commands for Displaying EEE Settings

Command

Purpose

show eee capabilities interface interface-idDisplays EEE capabilities for the specified interface.

show eee status interface interface-id

Displays EEE status information for the specified interface.

Catalyst 2960-X Switch Interface and Hardware Component Configuration Guide, Cisco IOS Release 15.0(2)EX

OL-29034-01

91

Image 103
Contents First Published July 10 Americas HeadquartersPage N T E N T S Contents Configuring Auto-MDIX41 Configuring System MTU Configuring EEE Viii Convention Description Document ConventionsBold font Element Vertical barsReader Alert Conventions Related Documentation Obtaining Documentation and Submitting a Service RequestXii Command Modes Information About Using the Command-Line InterfaceThis chapter contains the following topics Ctrl-Z Mode Access Method Prompt Exit Method About This ModeConfigure QuitHelp Using the Help SystemCommand or Action Purpose Step ModeNo and default Forms of Commands Understanding Abbreviated CommandsCLI Error Messages Error Message Meaning How to Use the CLI to Configure FeaturesConfiguration Logging Configuring the Command HistoryRecalling Commands Changing the Command History Buffer SizeCommand or Action Terminal no history Enabling and Disabling Editing FeaturesDisabling the Command History Feature Privileged Exec modeEditing Commands through Keystrokes Editing Command Lines That Wrap Show more command begin include exclude Searching and Filtering Output of show and more CommandsAccess-list Show more command begin include exclude regular-expressionCommand or Action Example OL-29034-01 This module contains the following topics Finding Feature InformationInformation About Configuring Interface Characteristics Interface TypesPort-Based VLANs Switch PortsTrunk Ports Switch Virtual InterfacesEtherChannel Port Groups Power over Ethernet PortsUSB Mini-Type B Console Port Using the Switch USB PortsUSB Type a Ports Interface ConnectionsConnecting VLANs with the Switch Interface Configuration ModeLayer 2 or switching mode switchport command VLANs 1 Default Ethernet Interface ConfigurationFeature Default SettingSpeed and Duplex Configuration Guidelines Interface Speed and Duplex ModeIeee 802.3x Flow Control Either gigabitethernet 1/0/1 How to Configure Interface CharacteristicsConfiguring Interfaces Procedure Gigabit Ethernet port 1 on switch 1 is selectedShow interfaces interface-id description Configure terminalAdding a Description for an Interface Description stringConfigure terminal Enters global configuration mode Configuring a Range of InterfacesInterface range port-rangemacro Verifies the configuration of the interfaces in the range Configuring and Using Interface Range MacrosDefine interface-range macroname Setting the Interface Speed and Duplex Parameters Configuring Ethernet InterfacesInterface range macro macroname Nonegotiate Speed 10 100 1000 auto 10Command or Action Purpose Configuring Ieee 802.3x Flow ControlEnd Returns to privileged Exec mode Configuring SVI Autostate ExcludeEnter interface configuration mode Interface vlan vlan-id gigabitethernet interface-id Switchport autostate excludeShutting Down and Restarting the Interface An SVI line state up or downShutdown Shuts down an interface Configuring the Console Media TypeThis configuration applies to all switches in a stack Configure terminal Line console Media-type rj45 EndConfigure terminal Enters the global configuration mode Configuring the USB Inactivity TimeoutShow interfaces interface-id switchport Monitoring Interface CharacteristicsCommand Purpose Show interfaces interface-id status err-disabledClearing and Resetting Interfaces and Counters Adding a Description to an Interface Example Configuration Examples for Interface CharacteristicsIdentifying Interfaces on a Stack-Capable Switch Examples Configuring a Range of Interfaces ExamplesSetting Interface Speed and Duplex Mode Example Configuring and Using Interface Range Macros ExamplesConfiguring the Console Media Type Example None Configuring the USB Inactivity Timeout ExampleTo disable the configuration, use these commands Standards and RFCs Standard/RFCTechnical Assistance Description Link Cisco IOS Release 15.02EX This feature was introducedRelease Modification OL-29034-01 Restrictions for Auto-MDIX Prerequisites for Auto-MDIXThis module contains the following sections Auto-MDIX on an Interface Information about Configuring Auto-MDIXHow to Configure Auto-MDIX Configuring Auto-MDIX on an InterfaceMonitoring Auto-MDIX This example shows how to enable auto-MDIX on a port Example for Configuring Auto-MDIXInformation about the Ethernet Management Port Prerequisites for Ethernet Management PortsSupported Features on the Ethernet Management Port Ethernet Management Port Direct Connection to a SwitchDisabling and Enabling the Ethernet Management Port How to Configure the Ethernet Management PortWhat to Do Next Additional ReferencesDocument Title Bootloader commandsRelated Topic MIBsOL-29034-01 Configuring LLDP, LLDP-MED, and Wired Location Service Lldp Supported TLVs Lldp and Cisco Switch StacksLldp and Cisco Medianet LLDP-MED Supported TLVs Wired Location Service Configuration Guidelines Default Lldp ConfigurationEnabling Lldp Configure terminal Lldp runLldp run Enables Lldp globally on the switch LLDP, and enter interface configuration modeShow lldp Verifies the configuration Configuring Lldp CharacteristicsLldp transmit Enables the interface to send Lldp packets Lldp receive Enables the interface to receive Lldp packetsSwitchconfig# lldp holdtime Command or Action Purpose Step Configuring LLDP-MED TLVsLldp med-tlv-select Specifies the TLV to enable Lldp med-tlv-select End Copy running-config startup-configConfiguration mode. The range is 1 to Configuring Network-Policy TLVDscp dvalue none untagged Voice voice-signalingvlan vlan-idcosShow network-policy profile Verifies the configuration Configuring Location TLV and Wired Location ServiceWay Use one of the followingEnters location information for an interface Exit Returns to global configuration modeInformation, and enter interface configuration mode Use one of the following Verifies the configurationCommand or Action Purpose Example Enabling Wired Location Service on the SwitchNmsp enable Enables the Nmsp features on the switch Configuring Network-Policy TLV ExamplesNmsp notification interval attachment location Command Description Civic location OL-29034-01 System MTU Guidelines Information about the MTUConfiguring the System MTU How to Configure MTU SizesShow system mtu Verifies your settings Configuration Examples for System MTUReload Reloads the operating system Additional References for System MTU Restrictions for PoE Configuring PoEInformation about PoE Power over Ethernet PortsSupported Protocols and Standards Class Powered-Device Detection and Initial Power AllocationPower Management Modes Power Monitoring and Power Policing Maximum Power Allocation Cutoff Power on a PoE Port Configuring a Power Management Mode on a PoE Port How to Configure PoEShow power inline Budgeting Power for Devices Connected to a PoE PortNever static max max-wattage No cdp run Optional Disables CDP Budgeting Power to All PoE portsConfigure terminal No cdp run Budgeting Power to a Specific PoE PortSpecifies the physical port to be configured, and enter Configuring Power PolicingPower inline consumption wattage Power inline police actionlog errdisable Power inline police actionlog errdisable ExitShow power inline police Show errdisable recovery Configuration modeWhile still providing power to the port Power inline police action log-Generates a syslog messageDown the port and puts the port in the error-disabled state Configuration Examples for Configuring PoE Monitoring Power StatusBudgeting Power Example EEE Overview Information About EEERestrictions for EEE How to Configure EEEDefault EEE Configuration EEE is disabled by defaultMonitoring EEE Specifies the interface to be configured, and enterPower efficient-ethernet auto CommandThis example shows how to enable EEE for an interface Configuration Examples for Configuring EEEThis example shows how to disable EEE for an interface Feature History and Information for Configuring EEE OL-29034-01 D E PoE