Cisco Systems UCSCPCIECSC02, 7000, N7KC7004, N7KC7018RF, N7KF248XP25E manual Americas Headquarters

Page 1

Se n d d o c u m e n t c o m m e n t s t o n ex u s 7 k - d o c f e e d b a ck @ c i s c o . c o m

Cisco Nexus 7000 Series Hardware Installation and Reference Guide

December 19, 2008

Americas Headquarters

Cisco Systems, Inc.

170 West Tasman Drive San Jose, CA 95134-1706

USA http://www.cisco.com Tel: 408 526-4000

800553-NETS (6387)

Fax: 408 527-0883

Customer Order Number:

Text Part Number: OL-12931-02

Image 1
Contents Americas Headquarters Page N T E N T S Prerequisites for Connecting Power Supply Units to AC Power Modules Displaying Epld Versions for an I/O or Supervisor Module Chassis Airflow A-12 Chassis and Module LEDs C-1 Audience PrefaceOrganization Chapter DescriptionConvention Description Document ConventionsConservez CES Informations Avvertenza Importanti Istruzioni Sulla Sicurezza Warnung Wichtige SicherheitshinweiseAviso Instruções Importantes DE Segurança Spara Dessa Anvisningar GEM Disse Anvisninger Preface Release Notes Related DocumentationObtaining Documentation and Submitting a Service Request Xviii Cisco Nexus 7000 Series OverviewCisco Nexus 7010 System Overview Cisco Nexus 7000 Series Mid-frame door assembly Air filter 187118 One Cisco Nexus 7010 Chassis Installed in a Four-Post Rack Cisco Nexus 7018 System Two Cisco Nexus 7010 Chassis Installed in a Four-Post Rack189972 Cable Management System for the 7018 Chassis Front doors OL-18634-01 Overview Cisco Nexus 7000 Series Preparing the Site 10 Cisco Nexus 7018 Chassis Installed in a Four-Post RackInstallation and Connection Guidelines Safety GuidelinesManaging the System Hardware Replacing Components Preparing to Install the Device Installing a Cisco Nexus 7010 ChassisRequired Tools Installing a Four-Post Rack or Cabinet Unpacking and Inspecting a New Device Installing the Bottom-Support Rails on the RackRequired Tools and Equipment Prerequisites for Attaching the Bottom-Support RailsAttaching the Bottom-Support Rails Part Description QuantityPage Positioning the Bottom-Support Rails Attaching a Bottom-Support Rail to a Rack Installing the ChassisPrerequisites for Installing the Chassis Installing the Chassis Moving a Cisco Nexus 7010 Chassis onto a Rack Attaching the Cisco Nexus 7010 Chassis to the Rack Grounding the Cisco Nexus 7010 ChassisPrerequisites for Grounding the Chassis Connecting the System GroundGrounding Port on the Front of the Cisco Nexus 7010 Chassis Grounding Port on the Rear of the Cisco Nexus 7010 Chassis Connecting Your ESD Strap to the ChassisESD port Installing and Formatting CompactFlash Cards 10 Aligning a CompactFlash Card to its Reader OL-18634-01 Installing a Cisco Nexus 7018 Chassis Installing a Four-Post Rack or Cabinet Prerequisites for Attaching the Bottom-Support Rails, Unpacking and Inspecting a New ChassisPrerequisites for Attaching the Bottom-Support Rails 192147 Installing a Cisco Nexus 7018 Chassis Installing the Chassis Prerequisites for Installing the Chassis Installing the Chassis Moving a Cisco Nexus 7018 Chassis onto a Rack Attaching the Cisco Nexus 7018 Chassis to the Rack Grounding the Cisco Nexus 7018 Chassis 185848 Grounding Port on the Cisco Nexus 7018 Chassis Installing the Cable Management Assemblies 192181 192182 192188 192189 Installing the Front Door and Air Intake Frame 13 Attaching the Left Door Stopper 14 Attaching the Right Door Stopper 192228 Step 17 Fastening Ball-Point Studs to the Air Intake Area 18 Positioning the Air Intake Frame on the Chassis 19 Attaching One Side of the Door to the Chassis 20 Attaching the Left Side of the Door 21 Attaching the Right Side of the Door 22 Aligning a CompactFlash Card to its Reader OL-18634-01 Installing Power Supply Units Installing Power Supply UnitsPrerequisites for Connecting Power Supply Units to AC Power Connecting the Power Supply Units to AC PowerConnecting 7.5-kW Power Supply Units Connecting 6-kW Power Supply Units250V, 20 a 250V, 20 a Statement Preparing for Connections Connecting the Cisco Nexus 7000 Device to the NetworkRequired Tools and Equipment COM1/AUX Serial Port Connecting to the ConsoleCreating an Initial Device Configuration Setting Up the Management Interface Connecting an I/O Module Connecting the Supervisor CMP PortConnecting or Disconnecting an SFP or SFP+ Port Connecting or Disconnecting a 1000Base-T PortInstalling a Transceiver Connecting a Fiber-Optic Cable with a Transceiver Maintaining Transceivers and Fiber-Optic Cables OL-18634-01 Displaying the Device Hardware Inventory Managing the Device HardwareExample 6-1 Displaying the Hardware Inventory CMP Clei Displaying the Device Serial Number Show sprom backplane 1 command. See ExampleExample 6-3 Displaying the Device Serial Number Example 6-4 Displaying Power Management Information Displaying Power Usage InformationPower Supply Configuration Overview Power Supply Configuration ModesFull Power SupplyCombined ModeCommand Purpose Power Supply Input Source Full Combined Redundancy ModePower System Available Supply Usage Scenario Result Power Supply Configuration GuidelinesUsage Power Scenario Result Power System Available Reserve SupplySupply Usage Power Scenario Result Power System Available ReserveSupervisor Modules Information About ModulesModule Terms Fixed or Relative Usage Modules Verifying the Status of a ModuleFabric Modules Status Output Description Checking the State of a ModuleShutting Down Modules Connecting to a ModuleOverview of Module Temperatures Information About Module TemperatureShutting Down a Supervisor or I/O Module Shutting Down a Fabric ModuleExample 6-6 Displaying Temperature Information for Hardware Displaying Module TemperatureExample 6-7 Displaying All Environmental Information Displaying Environment InformationReloading Modules Reloading the Device, Power Cycling Modules,Power Cycling Modules Saving the Module ConfigurationReloading the Device Scenario ConsequencePowering Off I/O Modules Purging the Module ConfigurationExample 6-8 Displays Chassis Fan Information Information About Fan TraysSystem Requirements Epld ConfigurationNX-OS Release Module Type Epld Device New Epld Version Updated EPLDsModule Type Epld Device Epld Version Module Type Epld Device New Epld VersionDownloading the Epld Images Installation GuidelinesChoose Latest Releases Preparing the Epld Images for InstallationExample Determining the Amount of Available Bootflash Memory Copy the Epld image to the standby supervisor Upgrading Epld ImagesExample 12 Epld Version Comparison Report-No Upgrade Needed Begin upgrading the Epld images by entering Y for yes Upgrading EPLDs for the Active Supervisor Module Upgrading EPLDs for a Fabric Module Upgrading EPLDs for a Fan Tray Module Displaying the Epld Versions Url commandDisplaying Epld Versions for a Fabric Module Parameters Default Default SettingsOL-18634-01 Getting Started TroubleshootingTroubleshooting the Power Supply Troubleshooting the Supervisor Modules Troubleshooting the Fan TraysTroubleshooting the Fabric Modules Troubleshooting the I/O Modules Contacting Customer Service Replacing a Power Supply Unit During Operations Removal and Installation ProceduresInstalling a Power Supply Unit During Operations Removing a Power Supply Unit During OperationsPage Replacing a Supervisor Module Unseating a Supervisor Module Removing the Plastic Protector from the Supervisor Module Replacing a Supervisor Module in a Single-Supervisor System Replacing an I/O Module Replacing an I/O Module Unseating an I/O Module Replacing a Fabric Module Replacing a Fabric Module During System OperationsMidplane connector see View C in Figure Replacing a Cisco Nexus 7010 System Fan Tray Replacing a Cisco Nexus 7010 Fabric Fan Tray Replacing a Cisco Nexus 7010 Fabric Fan TrayPush the card all the way into the reader Replacing a CompactFlash CardRemoving the Bottom Frame Removing the Front Doors Installing the Front Doors and Frame AssemblyInstalling the Front Doors Installing the Bottom Frame Replacing the Cisco Nexus 7010 System Air Filter Removing a Middle Door AssemblyOL-18634-01 OL-18634-01 Description Cisco Nexus Technical SpecificationsChassis Width Depth Height Component Weight per Unit QuantityPower Requirements for Device Components Component Quantity Maximum Typical Power Supply Configuration ModesTable A-7 Power Availability for 6-kW Power Supply Units Redundancy Mode Power cord Power Supply Cable SpecificationsReference LocaleCordset rating 16A Plug SI16S3 Local Cord rating Chassis Clearances Chassis Airflow Facility Cooling RequirementsFigure A-14 Airflow for the Cisco Nexus 7018 Chassis Appendix a Technical Specifications Chassis Airflow Module Connectors Cable and Port SpecificationsRJ-45 Connector SFP+ Transceivers SFP TransceiversCable Transceiver TypeParameter Minimum Appendix B Cable and Port Specifications SFP Transceivers Color Condition Chassis and Module LEDsStatus Status DescriptionACT LOG Table C-3 Module LEDs Table C-4describes the fabric module LEDs LED Indication Condition Powering Down the Cisco Nexus 7000 Series System Disconnecting the Cisco Nexus 7000 Series SystemDisconnecting the System from the Console Repacking the Cisco Nexus 7000 Series Device for ShipmentRepacking the System Components Disconnecting the System from the NetworkPrerequisites for Repacking the System Required Tools and Equipment for Repacking the SystemRepacking the Cisco Nexus 7010 Device Figure D-1 Packing a Power Supply Unit Page Figure D-2 Attaching the Chassis to the Shipping Pallet Figure D-3 Packing the System Components OL-18634-01 Site Preparation Checklist Site Preparation and Maintenance RecordsPlanning Activity Table E-2 Contact and Site Information Contact and Site InformationContract Number Chassis serial number Product number Chassis and Module InformationOL-18634-01 Numerics IN-2 IN-3 IN-4 IN-5 IN-6
Related manuals
Manual 74 pages 37.11 Kb Manual 40 pages 45.09 Kb Manual 26 pages 14.8 Kb Manual 2 pages 24.73 Kb

N6KC600164P, UCSCPCIECSC02, N7KF248XP25E, N7KF248XT25E, N7KF248XT25EP1 specifications

Cisco Systems 7000 series routers are pivotal in the landscape of networking, providing high-performance, reliable solutions for enterprise environments and service providers. These routers were designed to support the growing demands of digital communication, offering robust features that enhance connectivity and streamline network operations.

One of the primary characteristics of the Cisco 7000 series is its modular architecture. This allows for the integration of various interface modules and processing units, enabling organizations to customize their routers according to specific networking needs. The modularity supports scalability, as businesses can upgrade or replace components as their requirements evolve without having to replace the entire system.

The Cisco 7000 series incorporates advanced routing protocols, ensuring efficient data packet management and traffic flow. It supports multiple protocols, including OSPF, BGP, and EIGRP, facilitating seamless integration into a variety of network environments. This flexibility is essential in modern networks, where diverse communication protocols are in use.

Load balancing capabilities are another significant feature of the Cisco 7000 series. This functionality allows for the optimal distribution of network traffic across multiple paths, enhancing performance and redundancy. By ensuring that no single route is overwhelmed, organizations can maintain uptime and improve overall user experience.

Security is a top priority for many businesses, and the Cisco 7000 series addresses this need with built-in security features. It supports Virtual Private Networks (VPNs) and access control lists (ACL) to provide secure remote access and protect sensitive data from unauthorized access. This capability is vital in today’s threat landscape, where data breaches can have far-reaching consequences.

The series also boasts high throughput and low latency, making it suitable for bandwidth-intensive applications like video conferencing and cloud computing. Coupled with Quality of Service (QoS) features, the Cisco 7000 ensures that critical applications receive the bandwidth they need, thereby enhancing overall network performance.

In terms of manageability, the Cisco 7000 routers come equipped with advanced monitoring and diagnostic tools. Network administrators can easily track performance metrics and identify potential issues before they escalate, minimizing downtimes and maintaining business continuity.

In summary, the Cisco Systems 7000 series routers are a sophisticated solution for organizations seeking to optimize their networking infrastructure. With modularity, robust routing protocols, load balancing, security features, high performance, and comprehensive manageability, the Cisco 7000 series stands out as a reliable foundation for successful network operations in an increasingly connected world.