Cisco Systems 8540 Configuring POS SPE Scrambling, Scramble-atm, Scrambling is on by default

Page 19

Chapter 4 Configuring Interfaces

Configuring the POS OC-12c Uplink Interface (Catalyst 8540)

The value of the c2 byte is determined as follows:

If the value of the c2 byte has not been explicitly configured with the pos flag command, the SONET framer sends the following values:

For Cisco HDLC encapsulation with or without SPE scrambling: 0xCF

For PPP encapsulation with scrambling: 0x16 (RFC 2615)

For PPP encapsulation without scrambling: 0xCF (RFC 2615)

If the value of the c2 byte has been explicitly configured with the pos flag command, the configured value is sent regardless of the encapsulation method.

The value of the s1s0 bits is determined as follows:

If the value of the s1s0 bits have not been explicitly configured with the pos flag command, the SONET framer sends the following values:

For SONET framing, the default value is 0.

For SDH framing, the default value is 2.

If the value of the s1s0 bits have been explicitly configured with the pos flag command, the configured value is used regardless of the framing.

Configuring POS SPE Scrambling

SONET payload scrambling applies a self-synchronous scrambler of polynomial X**43+1 to the synchronous payload envelope (SPE) of the interface to ensure sufficient bit transition density. Both ends of the connection must use the same scrambling algorithm.

To configure POS SPE scrambling, perform the following steps, beginning in global configuration mode:

 

Command

Purpose

Step 1

 

 

Router(config)# interface pos

Enters interface configuration mode and specifies the POS

 

slot/subslot/interface

interface to configure.

 

Router(config-if)#

 

Step 2

 

 

Router(config-if)# no pos

Disables payload scrambling on the interface. Payload

 

scramble-atm

scrambling is on by default.

Step 3

 

 

Router(config-if)# no shutdown

Enables the interface with the previous configuration.

 

 

 

 

 

Layer 3 Switching Software Feature and Configuration Guide

 

 

 

 

 

 

 

78-6235-04, Cisco IOS Release 12.0(10)W5(18)

 

 

4-19

 

 

 

 

 

Image 19
Contents Configuring Interfaces Media Access Control Address Overview of Interface ConfigurationInterface Port Identifier Router# configure terminal General Instructions for Configuring InterfacesRouterconfig# interface gigabitethernet 1/0/1 About Layer 3 Switching Interfaces Example Initially Configuring Gigabit Ethernet InterfacesCommand Purpose About the Enhanced Gigabit Ethernet Interfaces CatalystVerifying the Ethernet Interface Configuration Initially Configuring Fast Ethernet InterfacesCommand Description Router# show interface gigabitethernet 0/0/0 ExamplesRouter# show interface fastethernet 1/0/0 About Virtual LANs Configuring ISL Vlan EncapsulationRouterconfig# bridge bridge-group protocol ieee Enters subinterface configuration modeRouterconfig-subif# Configure the Fast Ethernet main interface Routerconfig-if#Routerconfig-subif#interface fastethernet 3/0/1 Configuring 802.1Q Vlan EncapsulationRouterconfig# interface fastethernet 1/0/1.1 Routerconfig-subif#interface fastethernet 1/0/0Ieee Bridge-groupAbout Packet over Sonet Catalyst Monitoring Vlan OperationPOS About the POS OC-12c Uplink InterfaceConfiguring the POS OC-12c Uplink Interface Catalyst Initially Configuring the POS Interface Default ConfigurationParameter Configuration Command Default Value Line internal Automatic Reverting of Clock SourceIp-address subnet-mask Hdlc pppAdditional Configurations Customizing the ConfigurationSetting the MTU Size Value j0 value sls0 value Configuring FramingConfiguring Sonet Overhead Sdh sonetScrambling is on by default Configuring POS SPE ScramblingScramble-atm Configuring Sonet Alarms Alarm Configuring Sonet Delay TriggersAlarm Description Triggers line path millisecond Verifying the POS ConfigurationLais pais plop prdi slof SlosRouter# show protocols pos 1/0/0 LOP = PLM-P Router# show controllers pos 2/0/0Router# show controller pos 2/0/0 detail Smdr About the ATM Uplink Interface About ATM Uplinks CatalystNo atm sonet stm-1 for OC-3 Configuring the ATM Uplink Interface CatalystConfiguration Overview No loopbackParameter Value Initially Configuring the ATM Uplink InterfaceNo atm clock internal Atm vc-per-vpConfiguring the Clock Source ATM interface or to STM-4 for the OC-12c interface Configuring Sonet FramingRouterconfig-if# atm sonet Stm-1Line msg line 64byte exp-msg Overhead c2 byte j0 bytesMsg line j1 16byte exp-msg Sls0 is part of the payload pointer byteConfiguring Loopback Creating a PVC Configuring Virtual CircuitsConfiguring CDP Configuring the Maximum VCs per VPName Mapping a Protocol Address to a PVCVpi vci aal-encap Ip-address atm-vc vcdSwitch Router a Verifying the ATM ConfigurationSwitch Router B 5CB About Port Snooping Configuring Interfaces About Port SnoopingAbout the Snooping Source Port Configuring SnoopingRestrictions on Port Snooping About the Snooping Destination PortSource-port Direction receive transmit bothShow snoop Monitoring SnoopingShow snoop interface Destination-port78-6235-04, Cisco IOS Release 12.010W518