Cisco Systems 8510 CSR, 8540 CSR appendix Configuring Sonet Alarms

Page 20

Chapter 4 Configuring Interfaces

Configuring the POS OC-12c Uplink Interface (Catalyst 8540)

Configuring SONET Alarms

The OC-12c POS uplink interface supports SONET alarm monitoring. To configure alarm monitoring, perform the following steps, beginning in global configuration mode:

 

Command

Purpose

Step 1

 

 

Router(config)# interface pos

Enters interface configuration mode and specifies the POS

 

slot/subslot/interface

interface to configure.

 

Router(config-if)#

 

Step 2

 

 

Router(config-if)# pos report

Permits console logging of selected SONET alarms.

 

{b1-tca b2-tca b3-tca lais

The alarms are as follows:

 

lrdi pais plop prdi plm-p

 

b1-tca(B1 bit error rate [BER] threshold crossing alarm)

 

sd-ber sf-ber slof slos

 

uneq-p}

b2-tca(B2 BER threshold crossing alarm)

 

 

 

 

b3-tca(B3 BER threshold crossing alarm)

 

 

lais (line alarm indication signal)

 

 

lrdi (line remote defect indication)

 

 

pais (path alarm indication signal)

 

 

plop (path loss of pointer)

 

 

prdi (path remote defect indication)

 

 

plm-p(payload label, C2 mismatch alarm)

 

 

sd-ber(LBIP BER in excess of threshold)

 

 

sf-ber(signal failure BER)

 

 

slof (section loss of frame)

 

 

slos (section loss of signal), uneq-p(path unequipped C2

 

 

alarm).

 

 

The b1-tca,b2-tca,b3-tca,sf-ber,slof, and slos errors are

 

 

reported by default.

Step 3

 

 

Router(config-if)# pos threshold

Sets the BER threshold values of the specified alarms. Default

 

{b1-tca b2-tca b3-tca sd-ber

values are 6 for b1-tca, b2-tca, b3-tca, and sd-ber; 3 for sf-ber.

 

sf-ber}rate

 

Step 4

 

 

Router(config-if)# pos ais-shut

Sends a line alarm indication signal (AIS-L) to the other end of

 

 

the link after a shutdown command has been issued to the

 

 

specified POS interface. By default, the AIS-L is not sent to the

 

 

other end of the link.

 

 

You can stop transmitting the AIS-L by issuing either the

 

 

no shutdown or the no pos ais-shut commands.

 

 

 

To determine which alarms are reported on the POS interface, and to display the BER thresholds, use the show controllers pos command, as described in the next section, “Verifying the POS Configuration” section on page 4-22.For a detailed description of the pos report and pos threshold commands, refer to the Cisco IOS Interface Command Reference publication.

 

Layer 3 Switching Software Feature and Configuration Guide

4-20

78-6235-04, Cisco IOS Release 12.0(10)W5(18)

Image 20
Contents Configuring Interfaces Interface Port Identifier Overview of Interface ConfigurationMedia Access Control Address Routerconfig# interface gigabitethernet 1/0/1 General Instructions for Configuring InterfacesRouter# configure terminal About Layer 3 Switching Interfaces Initially Configuring Gigabit Ethernet Interfaces Command PurposeAbout the Enhanced Gigabit Ethernet Interfaces Catalyst ExampleCommand Description Initially Configuring Fast Ethernet InterfacesVerifying the Ethernet Interface Configuration Router# show interface fastethernet 1/0/0 ExamplesRouter# show interface gigabitethernet 0/0/0 Configuring ISL Vlan Encapsulation About Virtual LANsEnters subinterface configuration mode Routerconfig-subif#Configure the Fast Ethernet main interface Routerconfig-if# Routerconfig# bridge bridge-group protocol ieeeConfiguring 802.1Q Vlan Encapsulation Routerconfig# interface fastethernet 1/0/1.1Routerconfig-subif#interface fastethernet 1/0/0 Routerconfig-subif#interface fastethernet 3/0/1Bridge-group IeeeMonitoring Vlan Operation About Packet over Sonet CatalystAbout the POS OC-12c Uplink Interface POSConfiguring the POS OC-12c Uplink Interface Catalyst Parameter Configuration Command Default Value Default ConfigurationInitially Configuring the POS Interface Automatic Reverting of Clock Source Ip-address subnet-maskHdlc ppp Line internalSetting the MTU Size Customizing the ConfigurationAdditional Configurations Configuring Framing Configuring Sonet OverheadSdh sonet Value j0 value sls0 valueScramble-atm Configuring POS SPE ScramblingScrambling is on by default Configuring Sonet Alarms Alarm Description Configuring Sonet Delay TriggersAlarm Verifying the POS Configuration Lais pais plop prdi slofSlos Triggers line path millisecondRouter# show protocols pos 1/0/0 Router# show controllers pos 2/0/0 LOP = PLM-PRouter# show controller pos 2/0/0 detail Smdr About ATM Uplinks Catalyst About the ATM Uplink InterfaceConfiguring the ATM Uplink Interface Catalyst Configuration OverviewNo loopback No atm sonet stm-1 for OC-3Initially Configuring the ATM Uplink Interface No atm clock internalAtm vc-per-vp Parameter ValueConfiguring the Clock Source Configuring Sonet Framing Routerconfig-if# atm sonetStm-1 ATM interface or to STM-4 for the OC-12c interfaceOverhead c2 byte j0 bytes Msg line j1 16byte exp-msgSls0 is part of the payload pointer byte Line msg line 64byte exp-msgConfiguring Loopback Configuring Virtual Circuits Configuring CDPConfiguring the Maximum VCs per VP Creating a PVCMapping a Protocol Address to a PVC Vpi vci aal-encapIp-address atm-vc vcd NameSwitch Router B Verifying the ATM ConfigurationSwitch Router a 5CB Configuring Interfaces About Port Snooping About Port SnoopingConfiguring Snooping Restrictions on Port SnoopingAbout the Snooping Destination Port About the Snooping Source PortDirection receive transmit both Source-portMonitoring Snooping Show snoop interfaceDestination-port Show snoop78-6235-04, Cisco IOS Release 12.010W518