Configuring Headend Broadband Access Router Features
Setting Service Options
Troubleshooting Tips
To troubleshoot the configuration, perform the following tasks:
•Make sure you entered the correct port and cable modem card slot number when you activated DHCP giaddr.
•A
Setting Service Options
The following sections describe configurable service options for the Cisco uBR7200 series.
Configuring ToD Service
To activate ToD service for the Cisco uBR7200 series, use the following command in global configuration mode:
Command | Purpose |
|
|
CMTS01(config)# cable | Enables ToD service for the Cisco uBR7200 series. |
|
|
To disable ToD service (the default) after it has been enabled, enter the no cable
Verifying ToD Service
To verify whether or not ToD service has been activated, enter the show
Troubleshooting Tips
To troubleshoot the configuration, make sure you are in global configuration mode.
Setting Optional IP Parameters
Additional IP parameters can be set to enable downstream echoing of upstream data. To configure these optional IP parameters, perform the tasks in the following sections:
•Activating IP Multicast Echo
•Activating IP Broadcast Echo
Note The default values for the commands used in these configuration steps are adequate in most cases to configure the Cisco uBR7200 series.
Cisco IOS Multiservice Applications Configuration Guide