Installing the 9Cx14 Chassis

Redundant Power Supply Modules

The 9C114 and 9C714 support the installation of two power supplies for power supply redundancy and load sharing. If a 9C500 Power Box is used, up to six power supplies may be installed.

9C300-1 Environmental Module

The 9C300-1 Environmental Module provides out-of-band management capabilities, monitors power supply and environmental status, and has a built-in cooling system. The 9C300-1 Environmental Module is also “hot swappable” so that it can be removed for repair or replacement without causing network downtime. For details refer to the SmartSwitch 9000 9C300-1 Environmental Module User’s Guide.

The Backplane

The 9C114 SmartSwitch 9000 provides six distinct backplane buses, and the 9C714 provides an additional seventh bus, the Cell Transfer Matrix. Each bus serves a particular set of needs. The seven backplane buses are shown in Figure 1-1.

System Management Bus 1

System Management Bus 10

Flexible Network Bus 1

Flexible Network Bus 2

Inter-Networking Bus A

Inter-Networking Bus B

Cell Transfer Matrix

Figure 1-1. The SmartSwitch 9000 Backplane Buses

1-2

Image 10
Contents SmartSwitch 9C114 and 9C714 Chassis Installation Guide Page Page Vcci Notice FCC NoticeIndustry Canada Notice Declaration of Conformity Addendum European Representative AddressPage Contents Contents SmartSwitch FeaturesFlexible Network Bus Descriptions of the seven backplane buses are as follows Getting Help Your email addressSite Guidelines InstallationUnpacking the SmartSwitch 9000 Chassis Required ToolsInstallation Order Rack Mounting the Chassis Rack Mounting the ChassisInstalling a Power Supply Installing a Power Supply Attaching the Electrostatic Discharge ESD Wrist Strap Attaching the ESD Wrist StrapInstalling the Environmental Module Installing SmartSwitch 9000 Interface Modules Installing the Environmental ModuleInstalling SmartSwitch 9000 Interface Modules Attaching 9C614 INB Terminator Modules Powering up the SmartSwitch Attaching the INB Terminator ModulesRegulatory Compliance Operating SpecificationsEnvironmental Requirements 9C114 MMAC-Plus Chassis9C714 MMAC-Plus Chassis 9C214-1 Power Supply9C300-1 Environmental Module 9C614 INB Terminator Module