Installing the 9Cx14 Chassis

Site Guidelines

The following guidelines must be followed to select a suitable site for the SmartSwitch 9000. If not, unsatisfactory network performance may result.

The site must have an unrestricted free surface area around the SmartSwitch 9000 chassis, allowing for free movement of air. An open space of at least 84 high by

63.5wide by 81.24 centimeters deep (33 high by 25 wide by 32 inches deep) is the minimum recommended. If the unit is installed in an enclosed equipment cabinet, the cabinet should have a built-in cooling fan.The maximum theoretical heat dissipation of the SmartSwitch 9000 is 8700 BTUs per hour. Actual heat dissipation will vary depending on the modules installed in the SmartSwitch 9000 chassis. The temperature of the location must be maintained between 5° and 40°C (40° and 104°F). Changes in temperature greater than 10°C (18°F) per hour should not occur.

A standard 3-prong power receptacle must be located within 6 feet of the system. One circuit is recommended for each power supply. The AC wiring for the receptacle must be able to supply 12 amps at 120 volts or 6 amps at 220 volts.

Installation

Required Tools

The following tools are required to install the 9C114 and 9C714 chassis:

Phillips Screwdriver

Flathead Screwdriver

Electrostatic Discharge (ESD) Wrist Strap (provided with the chassis)

Unpacking the SmartSwitch 9000 Chassis

Unpack the chassis by following the steps below:

1.Remove the unit from the shipping box.

2.Remove the protective plastic bag.

3.Remove the accessory package.

4.Remove the Electrostatic Discharge (ESD) Wrist Strap package.

1-5

Image 13
Contents SmartSwitch 9C114 and 9C714 Chassis Installation Guide Page Page Vcci Notice FCC NoticeIndustry Canada Notice European Representative Address Declaration of Conformity AddendumPage Contents Contents Features SmartSwitchFlexible Network Bus Descriptions of the seven backplane buses are as follows Your email address Getting HelpUnpacking the SmartSwitch 9000 Chassis InstallationSite Guidelines Required ToolsInstallation Order Rack Mounting the Chassis Rack Mounting the ChassisInstalling a Power Supply Installing a Power Supply Attaching the ESD Wrist Strap Attaching the Electrostatic Discharge ESD Wrist StrapInstalling the Environmental Module Installing the Environmental Module Installing SmartSwitch 9000 Interface ModulesInstalling SmartSwitch 9000 Interface Modules Attaching 9C614 INB Terminator Modules Attaching the INB Terminator Modules Powering up the SmartSwitchEnvironmental Requirements Operating SpecificationsRegulatory Compliance 9C114 MMAC-Plus Chassis9C714 MMAC-Plus Chassis 9C214-1 Power Supply9C300-1 Environmental Module 9C614 INB Terminator Module