Installing the 9Cx14 Chassis
5.Check that all LEDs on the INB Terminator Module are green.
If the LEDs are any color other than green, refer to the INB Terminator Module Installation Guide.
6.Check that the Status and Alarm LEDs on the Environmental Module are green.
If the LEDs are not green, refer to the Environmental Module User’s Guide.
7.Check that the System Management Bus (SMB) and the Board OK (BOK) LEDs on the front panel of each installed Interface Module are green. (Be sure the boards have completed booting; this may take up to 20 seconds.)
If an Interface Module’s SMB and BOK LEDs are not green, refer to the User’s Guide for that Interface Module.
Operating Specifications
Environmental Requirements
Operating Temperature: | 5°C to 40°C (41°F to 104°F) |
Storage Temperature: | |
Operating Relative Humidity: | 5% to 90% |
Regulatory Compliance
Safety
This equipment meets the safety requirements of UL 1950, CSA C22.2 No. 950, EN 60950, IEC 950 and 73/23/EEC.
Electromagnetic Compatibility
This equipment meets the requirements of FCC Part 15, EN 55022,
VCCI
9C114 MMAC-Plus Chassis
Dimensions
76.2H x 48.3 W x 49.3 D centimeters (30 H x 19 W x 19.4 D inches)